HIMA X-BLK01 632590802模拟量模块

HIMA X-BLK01 632590802模拟量模块

HIMA X-BLK01 632590802模拟量模块检测到备份单元的配置错误。7 16#0000008 0未找到备份设备警告事件低在CEX总线上未找到备份单元。8 16#00000010 0备份报警介质上的I/O配置错误备份CI854A检测到从属单元的配置错误。9 16#00000020 0备份报警介质上的I/O连接错误备份CI854A检测到从属单元的配置错误。10 16#00000040 0备...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

HIMA X-BLK01 632590802模拟量模块

    HIMA X-BLK01 632590802模拟量模块

    检测到备份单元的配置错误。7 16#0000008 0未找到备份设备警告事件低在CEX总线上未找到备份单元。8 16#00000010 0备份报警介质上的I/O配置错误备份CI854A检测到从属单元的配置错误。9 16#00000020 0备份报警介质上的I/O连接错误备份CI854A检测到从属单元的配置错误。10 16#00000040 0备份CI854(A)上的硬件看门狗已过期警告事件低备份CI854/CI854A上的硬件监视器在超时内未被CI854/CIL854A固件触发。0 0在备份单元上检测到备份警告事件低A配置错误的PROFIBUS主配置错误。12 16#0000100 0备用报警介质PROFIBUS线路A上无活动。如果启用了线路冗余,则此警告反映了备用装置RxA LED的状态。13 16#0000200 0备用报警介质PROFIBUS线路B上无活动。如果启用了线路冗余,则此警告反映了备用装置RxB LED的状态。14 16#0000400 0 CI854A Backup Warning g Alarm Mediu m A硬件故障在备份单元上检测到硬件故障,例如RAM故障。

    A configuration error has been detected for the backup unit. 7 16#0000008 0 Backup device not found Warnin g Event Low The backup unit was not found on the CEX-Bus. 8 16#0000010 0 I/O configuration error on backup Warnin g Alarm Mediu m The backup CI854A has detected a configuration error for a slave unit. 9 16#0000020 0 I/O connection error on backup Warnin g Alarm Mediu m The backup CI854A has detected a configuration error for a slave unit. 10 16#0000040 0 Hardware watchdog on Backup CI854(A) expired Warnin g Event Low The HW watchdog on the backup CI854/CI854A was not triggered by the CI854/CI854A firmware within the timeout.0 0 Error in PROFIBUS master configuration of Backup Warnin g Event Low A configuration error has been detected on the backup unit. 12 16#0000100 0 No activity on PROFIBUS line A of Backup Warnin g Alarm Mediu m If line redundancy is enabled, this warning reflects the state of the RxA LED of the backup unit. 13 16#0000200 0 No activity on PROFIBUS line B of Backup Warnin g Alarm Mediu m If line redundancy is enabled, this warning reflects the state of the RxB LED of the backup unit. 14 16#0000400 0 Hardware fail of CI854A Backup Warnin g Alarm Mediu m A hardware failure has been detected on the backup unit, for example RAM failure.


    GE DS3820DMCB涡轮机控制板(图1)         GE DS3820DMCB涡轮机控制板(图1)         GE DS3820DMCB涡轮机控制板(图1)


    微信图片_20220816154436.png

    微信图片_20230209094814_副本 (2).jpg


    品牌:HIMA 

    型号:HIMA X-BLK01 632590802模拟量模块

    质保:365天

    成色:全新/二手