CTI 2500-RBC 901E-2500-RBC远程控制器
主和备用报警介质之间的PROFIBUS通信故障主和备用装置之间的PROFIBUS连接失败。26 16#00400000 0通信内存访问的警告事件高过载时间过长。应用程序任务对CI854/CI854A共享内存中PROFIBUS I/O数据的访问过多,因此CI854/CIL854A无法及时更新内存。27 16#00800000 0重复的从设备地址警告介质两个或多个PROFIBUS从设备具有相同的地址。28 16#1000000 0 PROFIBUS线路A无活动报警介质如果启用了线路冗余,则此警告反映主单元RxA LED的状态。
PROFIBUS com.
failure between
Primary and
Backup
Warnin
g
Alarm Mediu
m
The PROFIBUS connection
between primary and backup unit
failed.
26 16#0400000
0
Communication
memory obtained
too long
Warnin
g
Event High Overload of the communication
memory access. There is too
much access from the application
tasks to the PROFIBUS I/O-data in
the shared memory on the
CI854/CI854A so that the
CI854/CI854A cannot update the
memory in time.
27 16#0800000
0
Duplicate slave
address
Warnin
g
Alarm Mediu
m
Two or more PROFIBUS slaves
have the same address.
28 16#1000000
0
No activity on
PROFIBUS line A
Warnin
g
Alarm Mediu
m
If line redundancy is enabled, this
warning reflects the state of the
RxA LED of the primary unit.