SIMULATION ENABLED FOR(模拟启用时间):选择将启用模拟的所需时间长度。经过编程时间后,电流和电压模拟将关闭。如果选择了无限制,则将使用模拟电流和电压,直到通过模拟开/关设定点或串行端口关闭模拟,或直到PQM中的控制电源断开。•相位A/B/C/中性电流:输入模拟所需的相位和中性电流。•Vax/Vbx/Vcx电压:输入模拟所需的电压。输入的电压将是线路或相位量,取决于用S2系统设置\电流/电压配置\ VT接线设置点选择的VT接线类型。
SIMULATION ENABLED FOR: Select the desired length of time that simulation will be enabled. When the programmed time has elapsed, current and voltage simulation will turn off. If unlimited is selected, simulated currents and voltages will be used until simulation is turned off via the simulation on/off setpoint or via the serial port or until control power is removed from the PQM. • PHASE A/B/C/NEUTRAL CURRENT: Enter the desired phase and neutral currents for simulation. • Vax/Vbx/Vcx VOLTAGE: Enter the desired voltages for simulation. The voltages entered will be line or phase quantities depending upon the VT wiring type selected with the S2 SYSTEM SETUP \ CURRENT/VOLTAGE CONFIGURATION \ VT WIRING setpoint.