您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:stodcdcs@gmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

HIEE300024R4 N710315-8/15工控自动化卡件

HIEE300024R4 N710315-8/15工控自动化卡件

HIEE300024R4 N710315-8/15工控自动化卡件从机指示灯(HE697FBX100)指示灯表示电源“电源”指示灯。通电后,LED亮起。状态故障LED。FPGA编程后,此灯亮起。如果不是这样,或者如果TAXI芯片接收器检测到错误,它将关闭。信道1上的TX发射机活动。对于从属设备,仅存在通道1。信道1上的RX接收机活动。通道1的ON状态。图3.3–LED指示灯电源状态Ch1 TX Ch...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

HIEE300024R4 N710315-8/15工控自动化卡件

    HIEE300024R4 N710315-8/15工控自动化卡件

    从机指示灯(HE697FBX100)指示灯表示电源“电源”指示灯。通电后,LED亮起。状态故障LED。FPGA编程后,此灯亮起。如果不是这样,或者如果TAXI芯片接收器检测到错误,它将关闭。信道1上的TX发射机活动。对于从属设备,仅存在通道1。信道1上的RX接收机活动。通道1的ON状态。图3.3–LED指示灯电源状态Ch1 TX Ch1 RX Ch2 TX Ch2 RX Ch1 ON Ch2 ON主电源状态TX RX从属LED指示灯本数据表适用于IC693MDL753 12/24 V DC,0.5A正逻辑输出,32点http://www.cimtecautomation.com/parts/p-14675-ic693mdl753.aspx提供此GE Series 90-30模块的接线图和安装指南。有关更多信息,请致电1-800-784-9385联系Qualitrol技术支持support@qualitrol.com离散输出模块7 GFK-0898F第7章-离散输出模块7-49 12/24 V DC,0.5A正逻辑输出,32点IC693MDL753系列90-30可编程逻辑控制器的12/24 V直流,0.5A负逻辑输出模块提供32个离散输出。输出分为四组,每组八个(A1-A8、B1-B8、C1-C8和D1-D8);每个群体都有自己的共同点。输出是正逻辑或源型输出,因为它们切换电源正侧的负载,因此向负载提供电流。输出可以在+12至+24 VDC(+20%,-15%)范围内切换用户负载,并且能够提供每点0.5安培的最大电流。用户输入/输出连接器上为每个公用组提供了两个引脚。每个引脚的电流处理能力为3安培。建议在连接公共线时连接两个引脚;然而,这是高电流应用(3至4安培之间)的要求。每组可用于驱动不同的负载。例如,A、B和C组可以驱动24 VDC负载,而D组可以保留用于驱动12 VDC负载。向负载提供电流的电源必须由用户提供。该模块还从用户电源汲取最小量的电力,以向输出设备提供栅极驱动。场侧和逻辑侧之间的背板隔离由模块上的光耦合器提供。当CPU停止时,所有32个输出强制关闭。未报告任何特殊故障或报警诊断。模块顶部的LED指示灯(标记为A1-A8、B1-B8、C1-C8、D1-D8)提供每个输出点的开/关状态。该模块配置为32点输出类型,使用32位离散%Q输出数据。该模块可安装在Series 90-30 PLC系统中5或10插槽基板的任何I/O插槽中。输出电路通过安装在模块前部的两个24针阳连接器(Fujitsu FCN-365P024-AU)连接到用户负载设备。安装在模块右侧的连接器(前视图)与A组和B组连接。模块左侧的连接器与C组和D组连接。现场设备直接接线法–该方法使用的电缆在模块端具有匹配的母连接器,在另一端具有剥线和镀锡线。您可以购买一对预接线电缆,目录号为IC693CBL327和IC693CBL 328,或者,如果您的应用需要,您可以自己制作电缆。有关更多信息,请参阅本手册附录C中IC693CBL327/328数据表中的24针连接器建筑电缆。

    Indicators for Slave (HE697FBX100) Indicator Meaning POWER ‘Power’ indicator. Once power is applied, the LED lights. STATUS Fault LED. This lights once the FPGA is programmed. It turns off if this is not so or if a TAXI chip receiver has detected an error. TX Transmitter activity on channel 1. For the slave, only channel 1 exists. RX Receiver activity on Channel 1. ON Status of channel 1. Figure 3.3 – LED Indicators POWER STATUS Ch1 TX Ch1 RX Ch2 TX Ch2 RX Ch1 ON Ch2 ON Master POWER STATUS TX RX Slave LED Indicators ONThis Datasheet is for the IC693MDL753 12/24 Volt DC, 0.5A Positive Logic Output, 32 Point http://www.cimtecautomation.com/parts/p-14675-ic693mdl753.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-30 module. For further information, please contact Qualitrol Technical Support at 1-800-784-9385 support@qualitrol.com Discrete Output Modules 7 GFK-0898F Chapter 7 – Discrete Output Modules 7-49 12/24 Volt DC, 0.5A Positive Logic Output, 32 Point IC693MDL753 The 12/24 volt DC, 0.5A Positive Logic Output module for the Series 90-30 Programmable Logic Controller provides 32 discrete outputs. The outputs are arranged in four isolated groups of eight (A1 - A8, B1 - B8, C1 - C8, and D1 - D8); each group has its own common. The outputs are positive logic or sourcing type outputs in that they switch the loads on the positive side of the power supply, and therefore supply current to the load. The outputs can switch user loads over the range of +12 through +24 VDC (+20%, –15%) and are capable of sourcing a maximum current of 0.5 amps per point. Two pins are provided on the user I/O connectors for each group common. Each pin has a current handling capability of 3 amperes. It is recommended that connections are made to both pins when connecting the common; however, it is a requirement for high current applications (between 3 and 4 amperes). Each group can be used to drive different loads. For example, group A, B, and C can drive 24 VDC loads, while group D can be reserved for driving 12 VDC loads. Power to provide current to the loads must be provided by the user. The module also draws a minimum amount of power from the user supply to provide gate drive to the output devices. Backplane isolation between the field side and logic side is provided by opto-couplers on the module. All 32 outputs are forced OFF when the CPU is stopped. There are no special fault or alarm diagnostics reported. LED indicators (labeled A1 - A8, B1 - B8, C1 - C8, D1 - D8) at the top of the module provide the ON/OFF status of each output point. This module is configured as a 32-point output type and uses 32 bits of discrete %Q output data. This module can be installed in any I/O slot of a 5 or 10-slot baseplate in a Series 90-30 PLC system. Connections from the output circuits are made to the user load devices from two male (pin-type) 24-pin connectors (Fujitsu FCN-365P024-AU) mounted on the front of the module. The connector mounted on the right of the module (front view) interfaces with groups A and B. The connector on the left side of the module interfaces with groups C and D. Wiring to Field Devices Direct Method – This method uses cables that have a mating female connector on the module end and stripped and tinned wires on the other end. You can purchase a pair of pre-wired cables, catalog numbers IC693CBL327 and IC693CBL328 or, if required for your application, build your own cables. Refer to Building Cables for 24-Pin Connectors in the IC693CBL327/328 data sheet in Appendix C of this manual for more information.

    2022.11.29.jpg

    2022.11.25.jpg

    公司简介_副本.jpg

    手机轮播图2(1)_副本.jpg



    品牌:ABB

    型号:HIEE300024R4 N710315-8/15 

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号