您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:xiamen2018@foxmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

HIEE300550R1 DCS工控模块备件

HIEE300550R1 DCS工控模块备件

HIEE300550R1 DCS工控模块备件*提供额外的电缆夹(每包12个),目录号IC697ACC737。直径6.35 mm(0.25英寸)。(数量2)前视图,安装尺寸483 mm(19.00英寸)465 mm(18.31英寸)安装面侧视图,间距要求75 mm(2.95英寸)108mm(4.25英寸)图453:电缆夹IC697ACC736示意图PACSystems*RX3i系统手册附录GFK-2...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

HIEE300550R1 DCS工控模块备件

    HIEE300550R1 DCS工控模块备件

    *提供额外的电缆夹(每包12个),目录号IC697ACC737。直径6.35 mm(0.25英寸)。(数量2)前视图,安装尺寸483 mm(19.00英寸)465 mm(18.31英寸)安装面侧视图,间距要求75 mm(2.95英寸)108mm(4.25英寸)图453:电缆夹IC697ACC736示意图PACSystems*RX3i系统手册附录GFK-2314T 2019年9月电缆屏蔽夹组件873 C-1安装电缆夹组件应安装接地板靠近基板。电缆夹提供机械释放和电气接地。通过将电缆夹滑入所选电缆位置的两个相邻槽中,电缆夹连接到接地板上。拆除电缆外盖的所需部分后,将电缆插入接地板和电缆夹之间。顺时针转动指旋螺钉,拧紧电缆夹。不要过度拧紧指旋螺钉:用手拧紧或用工具轻轻拧紧。如果在涂漆表面上安装接地板,则必须在安装接地板的位置去除油漆,以确保接地板和安装表面之间的良好接地连接。17.2.3.1.19电缆直径可与电缆夹一起使用的最大直径电缆为0.51英寸(13mm)。可与电缆夹一起使用的最小电缆直径为屏蔽电缆,必须移除电缆,以允许电缆屏蔽和电缆夹之间的最大接触,如图455所示。电缆夹脚1.58“40mm屏蔽图455:绝缘盖拆除+24V直流输出图456:带扩展背板PACSystems*RX3i系统手册的典型电缆夹组件安装附录GFK-2314T 2019年9月电缆屏蔽夹组件875联系信息:北美和南美18703 GH Circle PO Box 508 Waller,Texas 77484 USA电话+1 281 727 5300 2500 Park Avenue West Mansfield,Ohio 44906 USA电话+1 419 529 4311 9009 King Palm Drive Tampa,Florida 33619 USA电话+1 813 630 2255 4112-91A Street Edmonton,Alberta T6E5V2 Canada电话+1 780 450 3600 Av。Hollingsworth,325 Iporanga Sorocaba,SP 18087-105巴西电话+55 15 3238 3788欧洲Asveldweg 11 7556 BT Hengelo(O)荷兰电话+31 74 256 1010 Siemensring 112 D-47877 Willich德国电话+49 2154 499 660 30/36 Allee du Plateau 93250 Villemomble France电话+331 48 122610 6 Bracken Hill西南工业区Peterle,Co Durham SR82LS,英国T+44艾默生产品的正确选择、使用和维护完全由买方负责。©2019 Emerson Electric Co.HE697FBX100和HE697FBX105光纤扩展接口用户手册第四版1998年11月20日MAN0215-04前言1998年11月份20日第2页前言本手册介绍了如何使用光纤扩展接口模块。版权所有(C)1998 Horner APG,LLC,640 North Sherman Drive,Indianapolis,Indiana 46201。保留所有权利。未经Horner APG,LLC事先同意和书面许可,不得以任何方式(电子、机械、磁性、光学、化学、手册或其他方式)复制、传输、转录、存储在检索系统中,或翻译成任何语言或计算机语言。根据Horner软件许可协议的条款和条件,本文档或媒体中描述的所有软件也是受版权保护的材料。本文件中的信息如有更改,恕不另行通知,不代表接口模块(主模块和从模块)的承诺;由HE制造的

    * Additional cable clamps available (12 per package), catalog number IC697ACC737. 6.35 mm (0.25 inch) dia. (Qty.2) Front View with Mounting Dimensions 483 mm (19.00 inches) 465 mm (18.31 inches) Mounting Surface Side View with Spacing Requirements 75 mm (2.95 inches) 108mm (4.25 inches) Figure 453: Cable Clamp IC697ACC736 Diagrams PACSystems* RX3i System Manual Appendix GFK-2314T Sept. 2019 Cable Shield Clamping Assembly 873 C-1 Installing the Cable Clamp Assembly The ground plate should be mounted near the baseplate. The cable clamp provides mechanical relief as well as electrical grounding. The cable clamp attaches to the ground plate by sliding it into two adjacent slots at the selected cable location. The cable is inserted between the ground plate and the cable clamp after removing the required section of the outer cover of the cable. Tighten the cable clamp by turning the thumbscrew clockwise. Do not over-tighten the thumbscrew: hand-tighten or tighten lightly with a tool. If you are installing the ground plate on a painted surface, the paint must be removed where the ground plate is to be mounted to ensure a good ground connection between the plate and mounting surface. 17.2.3.1.19 Cable Diameter The largest diameter cable that can be used with the cable clamp is 0.51 inches (13mm). The smallest cable diameter that can be used with the clamp is shielded cable must be removed to allow maximum contact between the cable shield and the cable clamp as displayed in Figure 455. Cable Clamp Foot 1.58" 40mm Shield Figure 455: Insulation Cover Removal + 24VDC OUTPUT Figure 456: Typical Cable Clamp Assembly installation with Expansion Backplane PACSystems* RX3i System Manual Appendix GFK-2314T Sept. 2019 Cable Shield Clamping Assembly 875 Contact Information: North & South America 18703 GH Circle PO Box 508 Waller, Texas 77484 USA T +1 281 727 5300 2500 Park Avenue West Mansfield, Ohio 44906 USA T +1 419 529 4311 9009 King Palm Drive Tampa , Florida 33619 USA T +1 813 630 2255 4112-91A Street Edmonton, Alberta T6E5V2 Canada T +1 780 450 3600 Av. Hollingsworth,325 Iporanga Sorocaba, SP 18087-105 Brazil T +55 15 3238 3788 Europe Asveldweg 11 7556 BT Hengelo(O) The Netherlands T +31 74 256 1010 Siemensring 112 D-47877 Willich Germany T +49 2154 499 660 30/36 Allee du Plateau 93250 Villemomble France T +331 48 122610 6 Bracken Hill South West Industrial Estate Peterlee, Co Durham SR82LS, United Kingdom T +44 Responsibility for proper selection, use and maintenance of any Emerson product remains solely with the purchaser. ©2019 Emerson Electric Co. User Manual for the HE697FBX100 & HE697FBX105 Fiber Optic Expansion Interface Fourth Edition 20 November 1998 MAN0215-04 PREFACE 20 NOV 1998 PAGE 2 PREFACE This manual explains how to use the Fiber Optic Expansion Interface Module. Copyright (C) 1998 Horner APG, LLC., 640 North Sherman Drive, Indianapolis, Indiana 46201. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior agreement and written permission of Horner APG, LLC. All software described in this document or media is also copyrighted material subject to the terms and conditions of the Horner Software License Agreement. Information in this document is subject to change without notice and does not represent a commitment Interface modules (master and slave); manufactured by HE is free from 

    2022.12.14.jpg

    2022.12.31.jpg

    手机轮播图2(1)_副本.jpg

    公司简介_副本.jpg



    品牌:ABB

    型号:HIEE300550R1 

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号