HIEE300690R1处理器模块

HIEE300690R1处理器模块

HIEE300690R1处理器模块PACSystems RX3i环境规范PACSystems*RX3i系统手册附录GFK-2314T 2019年9月产品认证和符合性安装指南853振动IEC60068-2-6,JISC0911 10-57 Hz,0.0524 mm(0.006 in)位移峰值峰值57-500 Hz,1.0 g加速度冲击IEC60068-2-27,JISC0912测试,模块主要进行阻尼...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

HIEE300690R1处理器模块

    HIEE300690R1处理器模块

    PACSystems RX3i环境规范PACSystems*RX3i系统手册附录GFK-2314T 2019年9月产品认证和符合性安装指南853振动IEC60068-2-6,JISC0911 10-57 Hz,0.0524 mm(0.006 in)位移峰值峰值57-500 Hz,1.0 g加速度冲击IEC60068-2-27,JISC0912测试,模块主要进行阻尼振荡波测试。107 EN 61000-4-x系列测试在技术上等同于IEC 61000-4-x。108不适用于最大安装长度小于30 m(98 ft)的通信或I/O线路。109不适用于最大安装长度小于30 m(98 ft)的通信线路。EMC IMMUNITY106静电放电EN 61000-4-2107±8 kV空气,±4 kV接触射频敏感性EN 61000-4-3107 10 Vrms/m,80至1000 MHz,安装长度小于3 m(9.1 ft)。112不适用于限制在30 m(98 ft)或以下的端口。113不适用于RS232端口和限制在30米(98英尺)或以下的端口114不适用于最大安装长度为3米(09.1英尺)或更短的通信或I/O线路PACSystems*RX3i系统手册附录GFK-2314T 2019年9月产品认证和安装指南858电压骤降和中断EN 61000-4-1110 AC输入功率:30%标称(0.5周期); 60%标称(5.50周期);>95%标称(250周期)电压变化EN 61000-4-1110交流输入功率:±10%(50000周期)电压闪变EN 61000-3-3交流输入功率;dmax£4%美国、加拿大、澳大利亚和欧洲政府法规旨在防止设备通过交流电源干扰经批准的传输或其他设备的运行。PACSystems RX3i系列产品经过测试,符合或超过了美国(47 CFR 15)、加拿大(ICES-003)、澳大利亚(AS/NZS 3548)和欧洲(EN55011)A级数字设备法规的要求。这些不同的法规在内容和测试级别上与CISPR 11有共同之处,基于这种共同性,对每个标准的测试被认为是不合适的。FCC要求根据FCC指南发布以下注意事项:注意:根据FCC规则第15部分,本设备经过测试,符合a类数字设备的限制。这些限制旨在为设备在商业环境中运行时提供合理的保护,防止有害干扰。本设备产生、使用和辐射射频能量,如果未按照说明书安装和使用,可能会对无线电通信造成有害干扰。在住宅区操作该设备可能会造成有害干扰,在这种情况下,用户需要自费纠正干扰。加拿大工业部要求发布以下注释:注释:该A类数字设备符合加拿大ICES-003。2012年8月后发布的模块要求在装置上标记以下信息或在用户文档中显示以下信息:CAN ICES-3(A)/NMB-3(A)标准符合性安装指南满足美国、加拿大、澳大利亚和欧洲A类数字设备法规,并保持CE标志合规性,包含下表中所列产品的RX3i装置必须安装在金属外壳中,外部布线在金属导管中,如本附录所述。未列出的模块仍必须安装在第2章“安装”中所述的保护外壳中。17.2.3.1.8需要安装在金属外壳中的模块描述目录号90-30系列输入模拟4点电压IC693ALG220 PACSystems*RX3i系统手册附录GFK-2314T 2019年9月产品认证和符合性安装指南859描述目录号Series 90-30输入模拟16sgl/8diff电流IC693ALGA223 RX3i输入模拟16sgl电流IC694ALG223系列90-30模拟2点输出电压IC693ALG390 RX3i模拟2点电压IC694ALGA390系列90-30输出模拟2点电流IC693ALGA391 RX3i输出模拟2点电流IC694ALG391 RX4i模拟输出8通道电流/电压IC694A LG392系列90-30模拟组合电流/电压4in/2outIC694ALG442 RX3i模拟模块4输入2输出电流/电压,带高级诊断IC694ALGA542系列90-30 I/O链路模块(从)IC693BEM320 RX3i I/O链路符合性指南860说明目录号系列90-30输入240 Vac 8点隔离IC693MDL231 RX3i输入240 Vac8点隔离IC 694MDL231系列90-30输出120 Vac 16点IC693MDL 240 RX3i

    PACSystems RX3i Environmental Specifications PACSystems* RX3i System Manual Appendix GFK-2314T Sept. 2019 Product Certifications and Installation Guidelines for Conformance 853 Vibration IEC60068-2-6, JISC0911 10 - 57 Hz, 0.0524 mm (0.006 in) displacement peak-peak 57 - 500 Hz, 1.0 g acceleration Shock IEC60068-2-27, JISC0912 test, modules were primarily tested to the Damped Oscillatory Wave test. 107 EN 61000-4-x series of tests are technically equivalent to the IEC 61000-4-x series. 108 Not applicable to communication or I/O lines with maximum installed length less than 30 m (98 ft). 109 Not applicable to communication lines with maximum installed length less than 30 m (98 ft). EMC IMMUNITY106 Electrostatic Discharge EN 61000-4-2107 ±8 kV Air, ±4 kV Contact RF Susceptibility EN 61000-4-3107 10 Vrms /m, 80 to 1000 MHz, installed length is less than 3 m (9.1ft). 112 Not applicable to ports limited to 30 m (98 ft) or less. 113 Not applicable to RS232 ports and those ports limited to 30 m (98 ft) or less 114 Not applicable to communication or I/O lines with maximum installed length 3 m (09.1 ft) or less PACSystems* RX3i System Manual Appendix GFK-2314T Sept. 2019 Product Certifications and Installation Guidelines for Conformance 858 Voltage Dips & Interrupts EN 61000-4-11110 AC Input Power: 30% Nominal (0.5 period); 60% Nominal (5.50 periods); >95% Nominal (250 periods) Voltage Variation EN 61000-4-11110 AC Input Power: ±10% (50,000 periods) Voltage Flicker EN 61000-3-3 AC Input Power: dmax £ 4% Government Regulations U.S., Canadian, Australian, and European regulations are intended to prevent equipment from interfering with approved transmissions or with the operation of other equipment through the AC power source. The PACSystems RX3i family of products has been tested and found to meet or exceed the requirements of U.S. (47 CFR 15), Canadian (ICES-003), Australian (AS/NZS 3548), and European (EN55011) regulations for Class A digital devices when installed in accordance with the guidelines noted in this manual. These various regulations share commonality in content and test levels with that of CISPR 11 and based on this commonality testing to each individual standard was deemed inappropriate. The FCC requires the following note to be published according to FCC guidelines: Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense. Industry Canada requires the following note to be published: Note: This Class A digital apparatus complies with Canadian ICES-003. Modules released after August 2012 require the following information be marked on the unit or appear in user documentation: CAN ICES-3 (A)/NMB-3 (A) Installation Guidelines for Conformance to Standards To meet U.S., Canadian, Australian, and European regulations for Class A digital devices and maintain CE Mark compliance, RX3i installations that include the products listed in the following table must be installed in a metal enclosure with external wiring routed in metal conduit as described in this appendix. Modules not listed must still be installed in a protective enclosure as described in Chapter 2, Installation. 17.2.3.1.8 Modules Requiring Installation in a Metal Enclosure Description Catalog Number Series 90-30 Input Analog 4-point Voltage IC693ALG220 PACSystems* RX3i System Manual Appendix GFK-2314T Sept. 2019 Product Certifications and Installation Guidelines for Conformance 859 Description Catalog Number Series 90-30 Input Analog 16sgl/8diff Current IC693ALG223 RX3i Input Analog 16sgl Current IC694ALG223 Series 90-30 Output Analog 2-point Voltage IC693ALG390 RX3i Output Analog 2-point Voltage IC694ALG390 Series 90-30 Output Analog 2-point Current IC693ALG391 RX3i Output Analog 2-point Current IC694ALG391 RX3i Analog Output 8-Channel Current/Voltage IC694ALG392 Series 90-30 Analog Combination Current/Voltage 4in/2out IC693ALG442 RX3i Analog Combination Current/Voltage 4in/2out IC694ALG442 RX3i Analog Module 4-Input 2-Output Current/Voltage with Advanced Diagnostics IC694ALG542 Series 90-30 I/O Link Module (Slave) IC693BEM320 RX3i I/O Link Guidelines for Conformance 860 Description Catalog Number Series 90-30 Input 240 Vac 8-point Isolated IC693MDL231 RX3i Input 240 Vac 8-point Isolated IC694MDL231 Series 90-30 Input 120 Vac 16-point IC693MDL240 RX3i

    2023.1.4.jpg

    2022.12.15.jpg

    手机轮播图2(1)_副本.jpg

    公司简介_副本.jpg



    品牌:ABB

    型号:HIEE300690R1 

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号