HIEE300690R1 ARC093AV1处理器模块,工控模块卡件
36点可拆卸接线板。仅限IC695ALGxxx、IC69xMDL660和IC694MDL664模块。不支持离散输出模块和热电偶模块。IC694CBL005屏蔽0.5米电缆,两端带有36针D型连接器终端。仅IC694TBC032和IC694TBB032 IC694CBL010屏蔽1.0米电缆,两端带有36针D型连接器终端。仅IC694TBC032和IC694TBB032 IC694CBL030屏蔽3.0米电缆,两端带有36针D型连接器终端。IC694TBC032和IC694TBB032仅IC694CBL130屏蔽3.0米电缆,连接至IC694TBC 032接线板的一端带有36针D型连接器终端。另一端未终止。IC694TBC032仅17.2.3.1.1 IC694RTB032高密度远程底座,36终端PACSystems*RX3i系统手册附录专用模块847图448:IC694RDB032高浓度远程底座,36终端PACSystems*RX3i系统手册附录专用模块848 17.2.3.1.2 IC694TBC032高密度接线板,带单36针D型连接器要将远程接线板IC694RTB032连接到I/O模块,I/O模块必须配备IC694TBC 032接线板。由于输入/输出模块和远程接线板均配有36点D型连接器,因此只需一根电缆即可将两者互连。此外,两端都配有处理屏蔽电缆的设备。这些特征提供了IC693ACC377 TBQC的显著优势。PACSystems*RX3i系统手册附录专用模块849图449:IC694TBC032带单36针D连接器的高密度接线板17.2.3.1.3 IC694CBL*电缆接线详情PACSystems*RX3i系统说明书附录专用模块850图450:IC694CBL*电缆接线详细PACSystems*RX3i系统手册附件GFK-2314T 2019年9月产品认证和符合性安装指南851产品认证和符合性安装准则本附录描述了PACSystems RX3i产品上的符合性标记以及产品认证所依据的相应标准。本附录还提供了符合标准的安装要求以及欧盟安装的附加安全指南。RX3i机构批准说明机构标准或标记注释N.A.保险商实验室根据UL508标准和同等CSA C22.2 No 142-M1987标准进行的工业控制设备认证的安全N.A.危险区域的安全I级,2区,A、B、C组,D保险商实验室根据ISA 12.12.01标准和同等CSA C22.2 No 213-M1987标准进行的认证,低压指令欧洲工业控制设备安全自我声明符合欧洲指令;请参阅www.geautomation.com上的符合性声明,以获得主管机构根据欧洲指令进行工业控制设备认证的批准产品电磁兼容性指令欧洲EMC的完整列表;请参阅www.geautomation.com上的符合性声明,以获取根据欧洲指令和独立第三方评估证书认证的爆炸性环境指令欧洲危险区域安全认证的批准产品的完整列表;请参阅www.geautomation.com上的PACSystems*RX3i系统手册声明附录GFK-2314T 2019年9月产品认证和符合性安装指南852设备组II,类别3,气体组A,B,C符合性,以获得批准产品的完整列表注:上述机构批准和符合性声明被认为是准确的;然而,机构对产品的批准应通过装置本身的标记进行验证。UL 1级2类危险区域要求对于1级2级危险区域,需要显示以下声明:1。标有I类A、B、C和D组2区危险位置的设备仅适用于I类2区A、B,C、D组或非危险位置。2.警告-爆炸危险-更换部件可能会影响I类2类的适用性。3.警告-爆炸危险-除非电源已关闭或该区域已知无危险,否则不要断开设备。4.设备应安装在只能使用工具ATEX 2区危险区域要求接近的外壳中。为保持符合ATEX指令,位于2区(3类)的RX3i系统必须安装在符合以下标准的保护外壳内:▪ IP54或更高▪ 承受3.5焦耳冲击能量的机械强度▪ 仅可使用工具标准
36-point removable terminal block. IC695ALGxxx, IC69xMDL660 and IC694MDL664 modules only. Discrete output modules and Thermocouple modules are not supported. IC694CBL005 Shielded 0.5-meter cable with 36-pin D-connector termination on both ends. IC694TBC032 and IC694TBB032 only IC694CBL010 Shielded 1.0-meter cable with 36-pin D-connector termination on both ends. IC694TBC032 and IC694TBB032 only IC694CBL030 Shielded 3.0-meter cable with 36-pin D-connector termination on both ends. IC694TBC032 and IC694TBB032 only IC694CBL130 Shielded 3.0-meter cable with 36-pin D-connector termination on the end that connects to the IC694TBC032 terminal block. The other end is unterminated. IC694TBC032 only 17.2.3.1.1 IC694RTB032 High-Density Remote Base, 36-Terminal PACSystems* RX3i System Manual Appendix Special Purpose Modules 847 Figure 448: IC694RTB032 High-Density Remote Base, 36-Terminal PACSystems* RX3i System Manual Appendix Special Purpose Modules 848 17.2.3.1.2 IC694TBC032 High-Density Terminal Block with Single 36-Pin D-Connector To connect the remote terminal block IC694RTB032 to an I/O module, the I/O module must be fitted with an IC694TBC032 terminal block. Since both the I/O module and the remote terminal block are fitted with 36-point D-connectors, only one cable is required to interconnect the two. Additionally, both ends are equipped to handle shielded cables. These features provide a significant advantage over the IC693ACC377 TBQC. PACSystems* RX3i System Manual Appendix Special Purpose Modules 849 Figure 449: IC694TBC032 High-Density Terminal Block with Single 36-Pin D Connector 17.2.3.1.3 IC694CBL* Cable Wiring Details PACSystems* RX3i System Manual Appendix Special Purpose Modules 850 Figure 450: IC694CBL* Cable Wiring Details PACSystems* RX3i System Manual Appendix GFK-2314T Sept. 2019 Product Certifications and Installation Guidelines for Conformance 851 Product Certifications and Installation Guidelines for Conformance This appendix describes the compliance markings that appear on PACSystems RX3i products and the corresponding standards to which the products have been certified. This appendix also provides installation requirements for conformance to standards and additional safety guidelines for installing in the European Union. RX3i Agency Approvals Description Agency Standard or Marking Comments N.A. Safety for Industrial Control Equipment Certification by Underwriter's Laboratories to UL508 standard and equivalent CSA C22.2 No 142 - M1987standard N.A. Safety for Hazardous Areas Class I, Div. 2, Groups A, B, C, D Certification by Underwriter's Laboratories to ISA 12.12.01 standard and equivalent CSA C22.2 No 213-M1987 standard Low Voltage Directive European Safety for Industrial Control Equipment Self-Declaration in accordance with European Directives; Refer to Declaration of Conformity found at www.geautomation.com for a complete list of approved products Electromagnetic Compatibility Directive European EMC for Industrial Control Equipment Certification by Competent Body in accordance with European Directives; Refer to Declaration of Conformity found at www.geautomation.com for a complete list of approved products Explosive Atmospheres Directive European Safety for Hazardous Areas Certification in accordance with European Directives and Independent 3rd Party Assessment Certificate; Refer to Declaration of PACSystems* RX3i System Manual Appendix GFK-2314T Sept. 2019 Product Certifications and Installation Guidelines for Conformance 852 Equipment Group II, Category 3, Gas Groups A, B, C Conformity found at www.geautomation.com for complete list of approved products Note: The agency approvals listed above and on the Declaration of Conformities are believed to be accurate; however, agency approvals for a product should be verified by the marking on the unit itself. UL Class 1 Division 2 Hazardous Areas Requirements The following statements are required to display for Class I Division 2 Hazardous Locations: 1. EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C, and D, DIV. 2 HAZARDOUS LOCATIONS IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C, D OR NON–HAZARDOUS LOCATIONS ONLY. 2. WARNING – EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. 3. WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON–HAZARDOUS. 4. EQUIPMENT SHALL BE INSTALLED INTO AN ENCLOSURE THAT IS ONLY ACCESSIBLE WITH THE USE OF A TOOL ATEX Zone 2 Hazardous Areas Requirements To maintain compliance with the ATEX Directive, an RX3i system located in a Zone 2 area (Category 3) must be installed within a protective enclosure meeting the following criteria: ▪ IP54 or greater ▪ Mechanical strength to withstand an impact energy of 3.5 Joules ▪ Only accessible with the use of a tool Standards