HIEE300690R1/ARC093A V1工控备件模块
板FCN–367T–T012/H这些工具必须从富士通授权经销商处订购。带有颜色代码的引脚连接如下图所示。电缆由12对双绞线组成;导线尺寸为#24 AWG(0.22mm2)。每对导线都有一根纯色导线和一根带有黑色示踪剂的同色导线。引脚编号对#电线颜色代码引脚编号对#电线颜色代码A1 1棕色B1 7紫色A2在PLC前面,而不是使用直角连接器的预制电缆(请参阅第17.2.1.1节“低密度、非屏蔽20-/24点TBQC”)。安装PLC的机柜的深度应考虑所选连接器添加的深度。2.187“1.5-2.5”典型PLC(侧视图)图442:使用直通式连接器的额外深度余量17.2.2低密度TBQC系统变体,用于32点I/O模块,带有双D连接器IC693ACC337提供24个端子(而不是20个)。它设计用于配备双D连接器的32点分立模块。此TBQC配置使用一对配对电缆(一个右出口和一个左出口),以便将I/O模块上的双D连接器连接到一对IC693ACC337接线板。兼容电缆将TBQC D连接器的引脚1连接到I/O模块上相应D连接器的针脚1,将引脚24连接到引脚24等。PACSystems*RX3i系统手册附录专用模块841图443:IC693ACC337接线端子顶视图和前视图17.2.2.1 IC693ACC 337 TBQC接线端子PACSystems*RX3i系统说明书附录专用模块842图444:IC693A CC337 TB质控接线端子注:提供公共行端子(标有字母C)是为了接线方便。它们的使用是可选的。它们与编号端子电气隔离。您可以按原样使用它们,也可以将它们跨接到带编号的端子。17.2.2.1连接电缆选择请参阅第17.2.1.1节,了解低密度、非屏蔽20-/24点TBQC。请记住,对于带有双D连接器的32点模块,需要选择左侧电缆和右侧电缆。17.2.2.10.2安装这些接线板安装在用户提供的标准35mm DIN导轨上。PACSystems*RX3i系统手册附录专用模块843 17.2.2.2将TBQC组件连接到32点模块面板上配备一对24针D连接器的32点模块可与TBQC接线板IC693ACC337一起使用。它们不需要20终端模块所描述的替代面板。由于每个32点输入/输出模块提供两个24针D型连接器,因此每个都需要两条电缆和两个IC693ACC337 TBQC接线板。此外,由于I/O模块上的两个连接器的方向不同(请参阅下图),因此每个电缆的出口都不同。GE提供“右侧”和“左侧”电缆,以简化安装。关于电缆选择,请参阅第17.2.1.1节“低密度、非屏蔽20-/24点TBQC”。安装后,电缆可以固定在模块底部的两个系紧装置上。注意:这些接线板不适用于具有50针连接器的32点I/O模块。PACSystems*RX3i系统手册附录专用模块844图445:双D连接器模块上的引脚分配17.2.3高密度TBQC系统概述高密度紧凑型远程终端底座IC694RTB032通过屏蔽电缆IC694CBL*(请参阅“高密度、屏蔽组件36-TBQC”一节)连接到I/O模块面板IC694TBC032,并支持这两种模拟和离散I/O模块,如下表所示。PACSystems*RX3i系统手册附录专用模块845图446:高密度TBQC系统概述图447:高浓度紧凑型远程终端底座IC694RTB032使用PACSystems*RX3i系统手册附件专用模块846 17.2.3.1高密度、,屏蔽36-TBQC零件号描述兼容性IC694TBB032型36点接线盒(参考第17.1.1.2节)。如手册中所列。IC694TBC032高密度接线板,带单36针D型连接器。仅限IC695ALGxxx、IC69xMDL660和IC694MDL664模块。不支持离散输出模块和热电偶模块。IC694RTB032高密度远程底座,带36针D连接器、屏蔽接地片和
Plate FCN–367T–T012/H These tools must be ordered from an authorized Fujitsu distributor. Pin connections with color codes are displayed in the following figure. Cables are made of 12 twisted pairs; wire size is #24 AWG (0.22mm2 ). Each pair has a solid color wire and the same color wire with a black tracer. Pin Number Pair # Wire Color Code Pin Number Pair # Wire Color Code A1 1 BROWN B1 7 VIOLET A2 front of the PLC than the prefabricated cables (refer to Section, 17.2.1.1 for Low-Density, Unshielded 20-/24-point TBQC), which use right–angle connectors. The depth of the cabinet that the PLC is mounted in should allow for the depth added by the selected connector. 2.187” 1.5-2.5” Typical PLC (Side View) Figure 442: Allowance for Extra Depth using Straight-On Connectors 17.2.2 Low-Density TBQC System Variant for 32-Point I/O Modules with Dual D-Connectors IC693ACC337 provides 24 terminals (versus 20). It is designed for use with those 32-point discrete modules that come equipped with dual D-connectors. This TBQC configuration uses a mated pair of cables (one rightegress and one left-egress) in order to connect the dual D-connectors on the I/O Module to a pair of IC693ACC337 terminal blocks. The compatible cables connect Pin 1 of the TBQC D-connector to Pin 1 of the corresponding D-connector on the I/O module, and Pin 24 to Pin 24, and such. PACSystems* RX3i System Manual Appendix Special Purpose Modules 841 Figure 443: IC693ACC337 Terminal Block Top and Front Views 17.2.2.1 IC693ACC337 TBQC Terminal Block PACSystems* RX3i System Manual Appendix Special Purpose Modules 842 Figure 444: IC693ACC337 TBQC Terminal Block Note: The common row terminals (labeled with the letter C) are provided for wiring convenience. Their use is optional. They are electrically isolated from the numbered terminals. You may use them as is, or jumper them to a numbered terminal. 17.2.2.1.1 Connecting Refer to Section, 17.2.1.1 for Low-Density, Unshielded 20-/24-point TBQC for cable selection. Remember that for interfacing with a 32-point module with dual D-connectors, it will be necessary to pick a left-side cable and a right-side cable. 17.2.2.1.2 Mounting These terminal blocks are mounted on a standard, user-supplied 35 mm DIN-rail. PACSystems* RX3i System Manual Appendix Special Purpose Modules 843 17.2.2.2 Connecting TBQC Components to 32-Point Modules Those 32-point modules equipped with a pair of 24-pin D-connectors on their faceplate may be used with TBQC terminal block IC693ACC337. They do not require a substitute faceplate as was described for the 20- terminal modules. Since each 32-point I/O module provides two 24-pin D-connectors, they will each require two cables and two IC693ACC337 TBQC terminal blocks. Additionally, since the two connectors on the I/O module are oriented differently (refer to figure below), the egress for each of the cables is different. GE supplies “right side” and “left side” cables to simplify installation. Refer to Section, 17.2.1.1 for Low-Density, Unshielded 20-/24-point TBQC for cable selection. After installation, cables can be secured to the two tie-downs on the bottom of the module. Note: These terminal blocks do not work with 32-point I/O modules that have 50-pin connectors. PACSystems* RX3i System Manual Appendix Special Purpose Modules 844 Figure 445: Pinout Assignments on Dual D-Connector Modules 17.2.3 High-Density TBQC System Overview The High-Density Compact Remote Terminal Base IC694RTB032 connects to the I/O module faceplate IC694TBC032 via a shielded cable IC694CBL* (refer to the section, Components for High-Density, Shielded 36- TBQC) and supports both analog and discrete I/O modules, as displayed in the following table. PACSystems* RX3i System Manual Appendix Special Purpose Modules 845 Figure 446: High-Density TBQC System Overview Figure 447: High-Density Compact Remote Terminal Base IC694RTB032 Usage PACSystems* RX3i System Manual Appendix Special Purpose Modules 846 17.2.3.1 Components for High-Density, Shielded 36-TBQC Part Number Description Compatibility IC694TBB032 Box-Style 36-point Terminal Block (refer to Section 17.1.1.2). As listed throughout the manual. IC694TBC032 High-Density terminal block with single 36-pin D-connector. IC695ALGxxx, IC69xMDL660 and IC694MDL664 modules only. Discrete output modules and Thermocouple modules are not supported. IC694RTB032 High-Density remote base, with 36-pin D-connector, shield ground lug and with a