您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:xiamen2018@foxmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

HIEE410372P201工业卡件,ABB卡件

HIEE410372P201工业卡件,ABB卡件

HIEE410372P201工业卡件,ABB卡件HART:IC695ALG626 IC695ALK62865 IC695ALG728如果用于HART直通,支持RX3i PROFINET控制器(PNC001)和PROFINET扫描仪(PNS001或CEP001)还必须包含HART兼容固件:IC695PNC001固件版本2.20 IC695PNS001固件版本2.30或PNS10166 IC695CE...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

HIEE410372P201工业卡件,ABB卡件

    HIEE410372P201工业卡件,ABB卡件

    HART:IC695ALG626 IC695ALK62865 IC695ALG728如果用于HART直通,支持RX3i PROFINET控制器(PNC001)和PROFINET扫描仪(PNS001或CEP001)还必须包含HART兼容固件:IC695PNC001固件版本2.20 IC695PNS001固件版本2.30或PNS10166 IC695CEP001固件版本2.3。PACSystems FDT HART DTM和PACSystems HART复用器的主要区别在于,它们设计用于不同类型的HART资产管理应用。·每当使用FDT框架应用程序(如GE Device Manager Essentials)配置和监控HART设备时,都会安装PACSystems FDT HART DTM™ 或其他FDT兼容的资产管理应用程序。·只要使用AMS配置和监测HART设备,就安装PACSystems HART多路复用器™ 来自艾默生过程管理™. 这两种技术都需要主机PC和PLC之间的以太网通信。请注意,两种解决方案中的PLC系统架构都相同。11.2带HART的模拟输入模块16-/8通道电流/电压:IC695ALG626 65如果使用,IC695ALD628必须安装在RX3i CPU机架中。在发布时,PROFINET扫描仪IC695PNS001或IC695CEP001不支持它。有关未来更新,请参阅IC695PNS001或IC695CEP001的IPI。66与HART一起使用时,使用PNS101代替PNS001,通常不会用于事件序列应用。PACSystems*RX3i系统手册第12节GFK-2314T 2019年9月带有HART通信的模拟模块496带有HART的模拟输入模块8-/4通道电流/电压:IC695ALG628 IC695ALD626 I1 I2 I3 I4 I5 16 I7 18 19 I10 I11 I12 I13 I14 I15 I16 Module OK FIELD STATUS TB图312:IC695ALL626非隔离差分模拟电流/电压输入模块IC695ALK628,提供8个单端或4个差分输入通道。非隔离差分模拟电流/电压输入模块IC695ALG626提供16个单端或8个差分输入通道。两个模块在每个信道上都具有HART 5.0版通信功能。模块IC695ALG626具有四个内部HART调制解调器。模块IC695ALG628具有两个内部HART调制解调器。在单端模式下,四个单端信道复用到每个HART调制解调器中。在差分模式下,两个差分信道复用到每个HART调制解调器中。模拟输入通道可配置为以下范围:§电流:0至20mA、4至20mA、±20mA§电压:±10 Vdc、0至10 Vdc、±5 Vdc、0到5 Vdc、1 Vdc到5 Vdc。将使用HART通信的信道必须配置为4-20mA范围。11.2.1功能§完全软件可配置,无需设置模块跳线§完全自动校准§车载错误检查§所有电压和4-20mA输入的开路检测§每个通道的可配置缩放和偏移§高报警、低报警、高高报警、,每个通道可选择的低-低报警检测和报告§模块故障报告§支持逻辑程序中的诊断点故障触点§闪存用于未来升级§正负变化率报警§启动时自动校准§通道报警和故障的可配置中断§接线板插入或移除检测§5.0版HART通信§这些模块必须位于RX3i通用背板中。§模块支持插入和取出通电的RX3i通用背板。参见第2.6.4.1节热插拔。这些模块可与盒型(IC694TBB032)、扩展盒型(IC 694TBB132)、弹簧型(IC6914TBS032)或扩展弹簧型(IC 6914TBS132)接线板一起使用。扩展接线板提供屏蔽布线所需的额外护罩深度。

    HART: IC695ALG626 IC695ALG62865 IC695ALG728 If used for HART Pass Through, the supporting RX3i PROFINET Controller (PNC001) and PROFINET Scanner (PNS001 or CEP001) must also contain HART-compatible firmware: IC695PNC001 Firmware Release 2.20 IC695PNS001 Firmware Release 2.30 or PNS10166 IC695CEP001 Firmware Release 2.30. The primary difference between the PACSystems FDT HART DTMs and the PACSystems HART Multiplexer is that they are designed to work with different types of HART asset management applications. · The PACSystems FDT HART DTMs are installed whenever the HART devices will be configured and monitored using an FDT Frame Application such as GE Device Manager Essentials™ or another FDTcompatible asset management application. · The PACSystems HART Multiplexer is installed whenever the HART devices will be configured and monitored using AMS™ from Emerson Process Management™. Both technologies require Ethernet communications between the host PC and the PLC. Note that the architecture of the PLC system is the same in either solution. 11.2 Analog Input Module 16-/8-Channel Current/Voltage with HART: IC695ALG626 65 If used, IC695ALG628 must be installed in the RX3i CPU Rack. At time of publication, it is not supported by PROFINET scanners IC695PNS001 or IC695CEP001. Refer to IPIs for IC695PNS001 or IC695CEP001 for future updates. 66 When used with HART, the PNS101 is used in place of PNS001, and would not typically be employed for Sequence of Events application. PACSystems* RX3i System Manual Section 12 GFK-2314T Sept. 2019 Analog Modules with HART Communications 496 Analog Input Module 8-/4-Channel Current/Voltage with HART: IC695ALG628 IC695ALG626 I1 I2 I3 I4 I5 16 I7 18 19 I10 I11 I12 I13 I14 I15 I16 MODULE OK FIELD STATUS TB Figure 312: IC695ALG626 Non-Isolated Differential Analog Current/Voltage Input module, IC695ALG628, provides 8 single-ended or 4 differential input channels. Non-Isolated Differential Analog Current/Voltage Input module, IC695ALG626, provides 16 single-ended or 8 differential input channels. Both modules feature HART version 5.0 communications capability on each channel. Module IC695ALG626 has four internal HART modems. Module IC695ALG628 has two internal HART modems. In single-ended mode, four single-ended channels are multiplexed into each HART modem. In differential mode, two differential channels are multiplexed into each HART modem. Analog input channels can be configured for these ranges: § Current: 0 to 20mA, 4 to 20mA, ±20mA § Voltage: ±10 Vdc, 0 to 10 Vdc, ±5Vdc, 0 to 5Vdc, 1 Vdc to 5Vdc. Channels that will use HART communications must be configured for the 4- 20mA range. 11.2.1 Features § Completely software-configurable, no module jumpers to set § Full auto-calibration § On-board error-checking § Open-circuit detection for all voltage and 4-20mA inputs § Configurable scaling and offsets per channel § High alarm, low alarm, high-high alarm, low-low alarm detection and reporting selectable per channel § Module fault reporting § Supports diagnostic point fault contacts in the logic program § Flash memory for future upgrades § Positive and negative Rate of Change Alarms § Auto-calibration at startup § Configurable interrupts for channel alarms and faults § Terminal Block insertion or removal detection § Version 5.0 HART communications § These modules must be located in an RX3i Universal Backplane. § Modules support insertion into and removal from an RX3i Universal Backplane which is under power. Refer to Hot Insertion and Removal, Section 2.6.4.1. The modules can be used with a Box-style (IC694TBB032), Extended Box-style (IC694TBB132), Spring-style (IC694TBS032), or Extended Spring-style (IC694TBS132) Terminal Block. Extended terminal blocks provide the extra shroud depth needed for shielded wiring.

    2022.12.9.jpg

    2022.12.06.jpg

    手机轮播图2(1)_副本.jpg

    公司简介_副本.jpg



    品牌: HIMA

    型号:HIEE410372P201 

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号