HIMA F3410输出卡件,机器人卡件

HIMA F3410输出卡件,机器人卡件

HIMA F3410输出卡件,机器人卡件模拟输出模块用户负载COM OUT COM OUT屏蔽仅在模块端连接端子排外壳GND可选接地连接接地用户负载图46:模拟输出屏蔽接地,带端子排PACSystems*RX3i系统手册第3节GFK-2314T 2019年9月安装62 2.6.4.11模块保险丝列表警告仅更换正确尺寸和类型的保险丝。使用不正确的保险丝可能会导致人员伤害、设备损坏或两者兼而有之。模块...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

HIMA F3410输出卡件,机器人卡件

    HIMA F3410输出卡件,机器人卡件

    模拟输出模块用户负载COM OUT COM OUT屏蔽仅在模块端连接端子排外壳GND可选接地连接接地用户负载图46:模拟输出屏蔽接地,带端子排PACSystems*RX3i系统手册第3节GFK-2314T 2019年9月安装62 2.6.4.11模块保险丝列表警告仅更换正确尺寸和类型的保险丝。使用不正确的保险丝可能会导致人员伤害、设备损坏或两者兼而有之。模块目录号(注)模块类型额定电流模块GE保险丝零件号其他来源和零件号IC694MDL3103 120 Vac、0.5A 3A 2 44A724627-111 Bussman–GMC-3 Littlefuse–239003 IC694MDL303 120/240 Vac、1A 5A 2 42G6101-0013 Bussman-S506-5-R Schurter-034.3124 IC694ML3403 120 Vac,0.5A 3A 2 44A724627-111 Bussman–GMC-3 Littlefuse–239003 IC694MDL3903 120/240 Vac,2A 3A 5 44A724627-111 Bussman-GMC-3 Littlefuse-239003 IC6914PWR3214 IC694PWR3304 120/240 Vac或125Vdc输入,30 W电源2A 1 44A724627 109 Bussman?215-002(GDC-2或GMC-2)Littlefuse-239-002 IC694PWR 3314 24Vdc输入,30 W电源5A 1 44A724627-114 Bussman–GMC-5-R 3保险丝安装在夹子中,从模块外壳上拆下电路板即可接近。4电源输入保险丝安装在夹子中,可通过拆下模块的前部进行操作。PACSystems*RX3i系统手册第3节GFK-2314T 2019年9月安装63 2.6.5 CPU安装:安装CPU:1。确保机架电源已关闭。将CPU模块安装在适当的插槽中(请参阅通用背板插槽占用规则,第2.6.1.3节)。除CPE302/CPE305外,CPU占用两个插槽,可以使用除编号最高(最右边)插槽之外的任何插槽。CPE302/CPE305占用一个插槽。3.打开电源。当CPU成功完成初始化时,OK(正常)指示灯保持亮起,RUN(运行)和EN(运行)指示灯熄灭。CPU现在可以编程了。4.对于带备用电池的CPU,将电池连接到模块上的任一电池连接器。(您可以在安装过程中的任何步骤连接电池,但除非通电,否则电池会立即耗尽。为了最大限度地延长电池寿命,请在打开电源后安装电池)。5.对于由Energy Pack备份的CPU,请遵循特定Energy Pack的安装说明。6.在适当的情况下,通信电缆可以固定在模块底部的系紧装置上。验证程序后,可将模式开关移至适当的操作模式位置:RUN I/O ENABLED(运行输入/输出启用)、RUN OUTPUT DISABLE(运行输出禁用)或STOP(停止)。LED指示灯指示模式开关的位置和串行端口活动的状态。图47:CPE330(2插槽CPU示例)注意:CPU不能热插入背板;在安装或卸下CPU之前,必须断开电源。PACSystems*RX3i系统手册第3节GFK-2314T 2019年9月安装64 2.6.6电源。将电源模块安装到相应的插槽中。a) 通用电源(IC695)可以安装在通用背板中编号最高(最右边)的插槽以外的任何插槽中。b) 扩展电源(IC694)必须安装在扩展背板的电源(最左侧)插槽中。c) 如果要使用多个电源,请参阅第2.6.1.2)2节“电源型号和插槽占用”。按照特定电源的安装说明将接线连接到电源。3.安装后,使用模块底部的三个接线系紧装置固定电源和接地线。电源P/S故障超温过载电源40W AC PACSystems™ RX3i图48:典型RX3i电源模块警告对于所有电源,如果使用同一输入电源为系统中的两个或多个电源供电,则每个电源的连接极性必须相同。由此产生的电位差可能会伤害人员或损坏设备。此外,每个背板必须连接到公共系统接地。PACSystems*RX3i系统手册第3节GFK-2314T 2019年9月安装65 2.6.6.1电源现场接线▪ 对于IC695电源,每个端子接受一根AWG#14至AWG#22导线。图49(下图)是IC695电源上一个端子的横截面图。每条电线的末端应至少剥开3/8英寸(9mm)。端子可接受剥开至11 mm(.433 in)的导线,同时提供绝缘体的完全固定。电线必须完全插入接线盒,如图49左侧所示,以使绝缘满足端子内部的绝缘停止位置。拧紧端子螺钉,使夹具牢固地抵住导线的剥皮端,将其固定到位。如果电线未完全插入,如右图所示,拧紧夹子可能会将电线向上推,从而使其无法连接。

    Analog Output Module User Load COM OUT COM OUT Shields Connected at module end only Terminal Strip Enclosure GND Optional Ground Connection Earth Ground User Load Figure 46: Analog Output Shield Grounding with a Terminal Strip PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 62 2.6.4.11 Module Fuse List WARNING Replace fuse only with the correct size and type. Using an incorrect fuse can result in harm to personnel, damage to equipment, or both. Module Catalog Number (note) Module Type Current Rating Quantity on Module GE Fuse Part Number Other Sources and Part Numbers IC694MDL3103 120 Vac, 0.5A 3A 2 44A724627-111 Bussman – GMC-3 Littlefuse – 239003 IC694MDL3303 120/240 Vac, 1A 5A 2 42G6101-0013 Bussman - S506-5-R Schurter - 034.3124 IC694MDL3403 120 Vac, 0.5A 3A 2 44A724627-111 Bussman – GMC-3 Littlefuse – 239003 IC694MDL3903 120/240 Vac, 2A 3A 5 44A724627-111 Bussman – GMC-3 Littlefuse – 239003 IC694PWR3214 IC694PWR3304 120/240 Vac or 125Vdc Input, 30 W Power Supply 2A 1 44A724627-109 Bussman – 215-002 (GDC-2 or GMC-2) Littlefuse – 239-002 IC694PWR3314 24Vdc Input, 30 W Power Supply 5A 1 44A724627-114 Bussman – GMC-5-R 3 Fuse is mounted in clip accessible by removing circuit board from module housing. 4 Power input fuse mounted in clip and accessible by removing front of module. PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 63 2.6.5 CPU Installation Ø To install the CPU: 1. Make sure that rack power is off. 2. Install the CPU module in the appropriate slot (refer to Universal Backplane Slot Occupancy Rules, Section 2.6.1.3). With the exception of CPE302/CPE305, the CPU occupies two slots and can use any slots except the highest numbered (rightmost) slot. CPE302/CPE305 occupies one slot. 3. Turn on power. When the CPU has successfully completed initialization, the OK LED stays on and the RUN and EN LEDs are off. The CPU is now ready to be programmed. 4. For CPUs with battery back-up, connect the battery to either of the battery connectors on the module. (You can connect the battery at any step in the installation process but it will begin to drain immediately unless power is applied. To maximize battery life, install it after power has been turned on). 5. For CPUs backed up by an Energy Pack, follow the installation instructions for the specific Energy Pack. 6. Where appropriate, communications cables can be secured to the tie-downs on the bottom of the module. After the program has been verified, the mode switch can be moved to the appropriate operation mode position: RUN I/O ENABLED, RUN OUTPUT DISABLE, or STOP. The LEDs indicate the position of the mode switch and status of serial port activity. Figure 47: CPE330 (example of 2-Slot CPU) CAUTION CPUs may NOT be hot-inserted in the backplane; power must be removed before installing or removing the CPU. PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 64 2.6.6 Power Supplies Ø To install the power supplies 1. Install the Power Supply module(s) in the appropriate slot(s). a) Universal Power Supplies (IC695) can be installed in any slot except the highest numbered (rightmost) slot in a Universal Backplane. b) Expansion Power Supplies (IC694) must be installed in the Power Supply (leftmost) slot in an Expansion Backplane. c) Where multiple power supplies are to be used, refer to Power Supply Models and Slot Occupancy, Section 2.6.1.2) 2. Connect wiring to the Power Supply per the installation instructions for that specific power supply. 3. Use the three wiring tie-downs on the bottom of the module to secure the power and ground wires after installation. POWER P/S FAULT OVERTEMP OVERLOAD Power Supply 40W AC PACSystems™ RX3i Figure 48: Typical RX3i Power Supply Module WARNING For all Power Supplies, if the same input power source is used to provide power to two or more power supplies in the system, connection polarity must be identical at each power supply. A resulting difference in potential can injure personnel or cause damage to equipment. Also, each backplane must be connected to a common system ground. PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 65 2.6.6.1 Power Supply Field Wiring ▪ For IC695 Power Supplies, each terminal accepts one AWG #14 to AWG #22 wire. Figure 49 (below) is a cross-section of one of the terminals on an IC695 Power Supply. The end of each wire should be stripped at least 3/8-inch (9mm). The terminal can accept a wire that is stripped up to 11 mm (.433 in) while providing full seating of the insulator. The wire must be fully-inserted into the terminal block as illustrated in Figure 49 at left, so that the insulation meets the insulation stop position inside the terminal. Tightening the terminal screw pivots the clamp firmly against the stripped end of the wire, holding it in place. If the wire is not fully inserted, as shown on the right, tightening the clamp may push the wire upward, so that it is not connected.

    2022.12.14.jpg

    2022.11.29.jpg

    手机轮播图2(1)_副本.jpg

    公司简介_副本.jpg

    21.jpg

    20.jpg

    23.jpg



    品牌: HIMA

    型号:HIMA F3410 

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号