HIMA H4135工控模块机器人备件
可以选择各种主放大器CT(50至250)。808709A1.CDR GCT5 GCT16尺寸尺寸A-6 469电机管理继电器GE Multilin A.3电流互感器附录A A.3.3相位CTS电流互感器最常见的比例为50:5至1000:5,可用作电机保护继电器的相位电流输入。这些带有安装硬件,也可用于1A辅助设备。电压等级:600 V BIL 10 kV。808712A1.CDR GE Multilin 469电机管理继电器B-1附录B B.1欧盟符合性声明B附录B其他。1欧盟符合性宣言欧盟符合性公告适用理事会指令:73/23/EEC低压指令89/336/EEC宣布符合的EMC指令标准:IEC 947-1低压开关设备和控制设备IEC1010-1:1990+A 1:1992+A 2:1995测量、控制和实验室用电气设备的安全要求CISPR 11/EN 55011:1997 A级-工业、科学和医疗设备EN 50082-2:1997电磁兼容性要求,第2部分:工业环境IEC100-4-3/EN 61000-4-3辐射射频抗扰性EN 61000-4-6传导射频抗扰度制造商名称:General Electric Multilin制造商地址:215 Anderson Ave.Markham,Ontario,Canada L6E 1B3制造商在欧盟的代表:Christina Bataller Mauleon GE Multilin Avenida Pinoa 10 48710 Zamudio,西班牙电话:34-94-4858835传真:34-9448858838设备类型:保护和控制继电器型号:469制造年份:1998我是下述签字人,特此声明,上述指定的设备符合上述指令和标准全名:John Saunders职位:制造经理签名:地点:GE Multilin日期:1998年8月20日B-2 469电机管理继电器GE Multiliin B.2保修信息附录B B B.2保修信息B.2.1保修通用Multilin继电器保修通用电气Multilin股份有限公司保证其制造的每个继电器在正常使用和服务条件下,自出厂之日起24个月内无材料和工艺缺陷。如果出现保修范围内的故障,GE Multilin将承诺维修或更换继电器,前提是保修人确定继电器存在缺陷,并将其退还给授权服务中心或工厂,并预付所有运输费用。保修期内的维修或更换将免费进行。保修不适用于任何因误用、疏忽、事故、不正确安装或使用而未按照说明使用的继电器,也不适用于在GE Multilin授权的工厂插座外改装的任何装置。GE Multilin不对因继电器故障、错误应用或调整而造成的特殊、间接或后果性损害、利润损失或费用承担责任。有关保修的完整文本(包括限制和免责声明),请参阅GE Multilin标准系列可编程自动化控制器(PAC)。与PACSystems系列的其他产品一样,RX3i具有单一控制引擎和通用编程环境,可跨多个硬件平台提供应用程序可移植性。本章概述了PACSystems RX3i产品和功能。本手册的其余部分详细描述了RX3i产品,并解释了安装过程。1.1修订本手册修订版本日期描述S Jul 18·增加IC695CPL410(新CPU模块)·增加IC69PNS101(RX3i事件序列的PNS模块)·更新了CPE330/CPE310/CPE305/CPE302的功率负载,·更新了具有两个硬件版本的PNC001和PNS001的功率负载。R 2018年3月增加了MDL340C的热降额(图181)。2018年2月Q更新了CPE302和CPE115。更新了图99和图105,以强调直流接地的必要性。删除了ALG112、ALG221、ALG223和ALG233的错误隔离电源信息。P Dec-17关于无机架CPU的第1.3节注释关于无串行端口CPU固件更新的基于web的工具的可用性的注释。ALG390电源连接的更正
Various Primary amp CTs can be chosen (50 to 250). 808709A1.CDR GCT5 GCT16 DIMENSIONS DIMENSIONS A-6 469 Motor Management Relay GE Multilin A.3 CURRENT TRANSFORMERS APPENDIX A A A.3.3 PHASE CTS Current transformers in most common ratios from 50:5 to 1000:5 are available for use as phase current inputs with motor protection relays. These come with mounting hardware and are also available with 1 A secondaries. Voltage class: 600 V BIL 10 kV. 808712A1.CDR GE Multilin 469 Motor Management Relay B-1 APPENDIX B B.1 EU DECLARATION OF CONFORMITY B APPENDIX B MISCELLANEOUSB.1 EU DECLARATION OF CONFORMITY EU DECLARATION OF CONFORMITY Applicable Council Directives: 73/23/EEC The Low Voltage Directive 89/336/EEC The EMC Directive Standard(s) to Which Conformity is Declared: IEC 947-1 Low Voltage Switchgear and Controlgear IEC1010-1:1990+ A 1:1992+ A 2:1995 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use CISPR 11 / EN 55011:1997 Class A – Industrial, Scientific, and Medical Equipment EN 50082-2:1997 Electromagnetic Compatibility Requirements, Part 2: Industrial Environment IEC100-4-3 / EN 61000-4-3 Immunity to Radiated RF EN 61000-4-6 Immunity to Conducted RF Manufacturer’s Name: General Electric Multilin Manufacturer’s Address: 215 Anderson Ave. Markham, Ontario, Canada L6E 1B3 Manufacturer’s Representative in the EU: Christina Bataller Mauleon GE Multilin Avenida Pinoa 10 48710 Zamudio, Spain Tel.: 34-94-4858835 Fax: 34-94-4858838 Type of Equipment: Protection and Control Relay Model Number: 469 First Year of Manufacture: 1998 I the undersigned, hereby declare that the equipment specified above conforms to the above Directives and Standards Full Name: John Saunders Position: Manufacturing Manager Signature: Place: GE Multilin Date: 08/20/1998 B-2 469 Motor Management Relay GE Multilin B.2 WARRANTY INFORMATION APPENDIX B B B.2 WARRANTY INFORMATION B.2.1 WARRANTY GE Multilin Relay Warranty General Electric Multilin Inc. (GE Multilin) warrants each relay it manufactures to be free from defects in material and workmanship under normal use and service for a period of 24 months from date of shipment from factory. In the event of a failure covered by warranty, GE Multilin will undertake to repair or replace the relay providing the warrantor determined that it is defective and it is returned with all transportation charges prepaid to an authorized service centre or the factory. Repairs or replacement under warranty will be made without charge. Warranty shall not apply to any relay which has been subject to misuse, negligence, accident, incorrect installation or use not in accordance with instructions nor any unit that has been altered outside a GE Multilin authorized factory outlet. GE Multilin is not liable for special, indirect or consequential damages or for loss of profit or for expenses sustained as a result of a relay malfunction, incorrect application or adjustment. For complete text of Warranty (including limitations and disclaimers), refer to GE Multilin Standard family of programmable automation controllers (PACs). Like the rest of the PACSystems family, the RX3i features a single control engine and universal programming environment to provide application portability across multiple hardware platforms. This chapter is an overview of PACSystems RX3i products and features. The rest of the manual describes RX3i products in detail, and explains installation procedures. 1.1 Revisions of this Manual Rev Date Description S Jul-18 · Addition of IC695CPL410 (new CPU module) · Addition of IC695PNS101 (PNS module for RX3i Sequence of Events) · Updated power loadings for CPE330/CPE310/CPE305/CPE302, · Updated power loadings for PNC001 & PNS001 which have two hardware versions. R Mar-18 Added Thermal Derating for MDL340C (Figure 181). Q Feb-18 Updated throughout for addition of CPE302, CPE115. Updated Figure 99 & Figure 105 to emphasize need for connecting DC- to Earth Ground. Deleted incorrect Isolated Power Supply information for ALG112, ALG221, ALG223, and ALG233. P Dec-17 Note in Section1.3 concerning rackless CPUs Notes throughout about availability of web-based tool for firmware updates for CPUs with no serial port. Correction for ALG390 power connection