您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

欢迎访问瑞昌明盛自动化设备有限公司网站!

图片名

全国订购热线:
+86 15270269218E-mail:xiamen2018@foxmail.com

主页 > 产品中心 > ICS TRIPLEX

ICS TRIPLEX

ABB >>

A-B>>

GE>>

BENTLY>>

ICS TRIPLEX T8222处理器模块

ICS TRIPLEX T8222处理器模块

ICS TRIPLEX T8222处理器模块c光标行复选框切换复选框以查看所需的图形按钮打印、帮助、保存(将值保存到文件)、打开、放大、缩小光标行要移动行,请将鼠标指针移动到光标行上。单击并按住鼠标左键并拖动到新位置GE Power Management 469 Motor Management Relay 8-15 8 469 PC SOFTWARE 8.3 USING 469PC 8 8.3....

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

ICS TRIPLEX T8222处理器模块

    ICS TRIPLEX T8222处理器模块

    c光标行复选框切换复选框以查看所需的图形按钮打印、帮助、保存(将值保存到文件)、打开、放大、缩小光标行要移动行,请将鼠标指针移动到光标行上。单击并按住鼠标左键并拖动到新位置GE Power Management 469 Motor Management Relay 8-15 8 469 PC SOFTWARE 8.3 USING 469PC 8 8.3.9 PHASORS 469PC软件可用于查看三相电流和电压的相量图。相量用于:•相电压A、B和C•相电流A、B、C 1。469PC运行并建立通信后,选择“实际”>“计量数据”菜单项,然后单击“相量”选项卡,打开“计量数据窗口”。将显示相量图、电压相量值和电流相量值。较长的箭头表示电压相量,较短的箭头表示电流相量。Va和Ia是基准(即零度相位)。滞后角为顺时针。图8–11:相量注释电压电平显示电压相量的值和角度电流相量短箭头电压相量长箭头电流电平显示电流相量的数值和角度8-16 469电机管理继电器GE电源管理8.3使用469PC 8 469 PC软件8 8.3.10事件记录469事件记录器可以使用469PC软件查看。事件记录器在每次发生事件(例如,电机跳闸)时存储电机和系统信息。最多可存储40个事件,其中EVENT01是最新的,EVENT40是最旧的。每当发生新事件时,EVENT40都会被覆盖。1.在469PC运行并建立通信后,选择“实际”>“事件记录”菜单项以打开“事件记录窗口”。此窗口显示事件列表,最新事件显示在顶部(参见下图)。2.按查看数据按钮查看所选事件的详细信息。3.视图数据窗口顶部的事件记录选择器允许用户滚动浏览不同的事件。4.选择“保存”将所选事件的详细信息存储到文件中。5.选择“打印”将事件发送到系统打印机,选择“确定”关闭窗口。6.事件记录器的更多信息可在“帮助”下找到。图8–12:469PC事件记录器显示显示上次事件的日期和自上次清除事件列表以来的事件总数最近显示在顶部的事件列表查看数据单击以显示所选事件的详细信息清除事件单击清除事件按钮以从内存中清除事件列表事件选择按钮按下全部按钮以选择所有事件“无”按钮可清除所有选择GE Power Management 469 Motor Management Relay 8-17 8 469 PC SOFTWARE 8.3 USING 469PC 8 8.3.11 TROUBLESHOOTING(使用469PC 8故障排除)本节提供了在Windows环境中遇到故障(例如,通用保护故障(GPF)、丢失窗口、打开/保存文件中的问题、,和应用程序错误消息)。如果469PC软件导致Windows系统错误:1。检查系统资源:•在Windows 95/98中,右键单击“我的电脑”图标,然后单击“性能”选项卡。•在Windows 3.1/3.11中,选择“帮助”

    ursor line CHECK BOX Toggle the check box to view the desired graphs BUTTONS Print, Help, Save (save values to a file), Open, Zoom In, Zoom Out CURSOR LINES To move lines, move the mouse pointer over the cursor line. Click and hold the left mouse button and drag to a new location GE Power Management 469 Motor Management Relay 8-15 8 469 PC SOFTWARE 8.3 USING 469PC 8 8.3.9 PHASORS The 469PC software can be used to view the phasor diagram of three phase currents and voltages. The phasors are for: • Phase Voltages A, B, and C • Phase Currents A, B, and C 1. With 469PC running and the communications established, open the Metering Data window by selecting the Actual > Metering Data menu item then clicking the Phasors tab. The phasor diagram and the values of voltage phasors, and current phasors are displayed. Longer arrows are the voltage phasors, shorter arrows are the current phasors. 2. Va and Ia are the references (i.e. zero degree phase). The lagging angle is clockwise. Figure 8–11: PHASORS NOTE VOLTAGE LEVEL Displays the value and the angle of the voltage phasors CURRENT PHASOR Short arrow VOLTAGE PHASOR Long arrow CURRENT LEVEL Displays the value and angle of the current phasors 8-16 469 Motor Management Relay GE Power Management 8.3 USING 469PC 8 469 PC SOFTWARE 8 8.3.10 EVENT RECORDING The 469 event recorder can be viewed with the 469PC software. The event recorder stores motor and system information each time an event occurs (e.g. motor trip). Up to 40 events can be stored, where EVENT01 is the most recent and EVENT40 is the oldest. EVENT40 is overwritten whenever a new event occurs. 1. With 469PC running and communications established, select the Actual > Event Recording menu item to open the Event Recording window. This window displays the list of events with the most current event displayed on top (see the figure below). 2. Press the View Data button to view the details of selected events. 3. The Event Record Selector at the top of the View Data Window allows the user to scroll through different events. 4. Select Save to store the details of the selected events to a file. 5. Select Print to send the events to the system printer, and OK to close the window. 6. More information for the event recorder can be found under Help. Figure 8–12: 469PC EVENT RECORDER DISPLAY Displays the date of last event and the total number of events since last clear EVENT LISTING List of events with the most recent displayed on top VIEW DATA Click to display the details of selected events CLEAR EVENTS Click the Clear Events button to clear the Event Listing from memory EVENT SELECT BUTTONS Push the All button to select all events Push the None button to clear all selections GE Power Management 469 Motor Management Relay 8-17 8 469 PC SOFTWARE 8.3 USING 469PC 8 8.3.11 TROUBLESHOOTING This section provides some procedures for troubleshooting the 469PC when troubles are encountered within the Windows environment (for example, General Protection Fault (GPF), Missing Window, Problems in Opening/Saving Files, and Application Error messages). If the 469PC software causes Windows system errors: 1. Check system resources: • In Windows 95/98, right-click on the My Computer icon and click on the Performance tab. • In Windows 3.1/3.11, select the Help

    2022.12.9.jpg

    2022.11.25.jpg

    fa405aeea632aa6912154382925a28b_副本.jpg

    手机轮播图2(1)_副本.jpg



    品牌:ICS TRIPLEX

    型号:ICS TRIPLEX T8222 

    产地:美国

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号