输出模块IC220MDL754 IC220MDL661 IC220MDL930 IC220MDL940产品名称输出24 VDC正输出24 VDC负输出继电器3.0 A 1点输出继电器3.0 1点逻辑0.5 A 16点逻辑0.5 2点输出电压24 VDC 24 VDC 5-253 VAC 5-253 VDC点数16 2 1 4连接类型2和3线2、3、4,以及4线2和3线2和三线负载电流每点0.5 A 0.5 A 3.0 A 3.0 A保护电子短路、电子短路、过载保护过载保护电流消耗90 mA最大32 mA最大60 mA最大187 mA来自本地总线UL(mA)额定电流消耗US 8 Amp最大1 Amp(2 x 0.5A),LED指示灯总线诊断状态总线诊断状态母线诊断状态总线故障状态输出指示输出指示输出输出指示所需端子排(4)IC220TBK123(1)IC220TB K082(1)IC 220TBK085(1)(包含10条)(包含十条)(含十条)需要继电器隔离设置需要如果开关电压为t,则继电器隔离设置(IC220ACC201和IC220TBK206)(IC220ACC 201和IC220 TBK206。在该细分市场中可用。Artisan技术集团-质量仪表。。。保证VersPoint 224 GE Fanuc控制器和I/O解决方案模拟输入模块接收来自电流和电压输入设备的信号。专用模块可用于RTD和热电偶输入。模拟输入模块屏蔽传感器电缆屏蔽传感器电缆传感器电缆屏蔽电缆转换器120微秒10微秒120微秒120微秒模块更新率小于1.5毫秒小于0.8至1.3毫秒20至30毫秒(取决于连接方法30毫秒)输入电阻大于220千欧姆大于240千欧姆(电压)和50欧姆(电流)输入滤波器40 Hz 3.5 Hz 48 Hz电流消耗45 mA,典型48 mA,典型43 mA,典型43mA,美国LED指示灯的本地总线UL(mA)额定电流消耗典型总线诊断总线诊断总线总线诊断所需端子排(1)IC220TBK062(4)IC220TB K062(1)IC 220TBK06(1)(包含5条)(包含五条)(含五条)。。。保证VersPoint GE Fanuc控制器和I/O解决方案225模拟输出模块为模拟输出设备提供电压或电流信号。模拟输出模块IC220ALG320 IC220ALF321 IC220ALG222产品名称模拟输出16位电压/模拟输出16比特电压模拟输出13比特电压标称电流消耗美国LED指示器总线诊断,总线诊断的I/O电压总线诊断默认状态设置模拟端子存在所需的端子排(1)IC220TBK203(包含1条)(1)IC 220TBK061(包含5条)(2)IC220TB K062(包含5个)Artisan技术组-质量仪表。。。VersPoint 226 GE Fanuc控制器和I/O解决方案运动模块保证用户能够轻松连接到高速输入设备。运动模块IC220MDD840 IC220MDD141 IC220MDD442产品名称高速计数器输入、绝对编码器输入、4位数字增量编码器输入、1位数字控制输入、,1个控制输出输入、4个数字输出输入和4个数字输入点数1个SSI编码器一个A QUAD B输入频率100Khz 400Khz高达500Khz分辨率26位26位输入数144输入电压24 VDC/5 VDC 24 VDC 24 VDC输出数144输出电压24 VDC、500mA 24 VDC、,500mA连接方式输入:2和3线输入:2线和3线输出:2线输出:3线输出和2线输出;2和3导线保护短路保护短路保护电流消耗40 mA(典型值),50 mA 60 mA 110 mA(本地总线)
Output Modules IC220MDL754 IC220MDL761 IC220MDL930 IC220MDL940 Product Name Output 24 VDC Positive Output 24 VDC Negative Output Relay 3.0 A 1 Point Output Relay 3.0 A 1 Point Logic 0.5 A 16 Points Logic 0.5 A 2 Points Output Voltage 24 VDC 24 VDC 5 - 253 VAC 5 - 253 VAC Number of Points 16 2 1 4 Connection Style 2 and 3 wire 2, 3, and 4 wire 2 and 3 wire 2 and 3 wire Load Current per Point 0.5 A 0.5 A 3.0 A 3.0 A Protection Electronic Short Circuit, Electronic Short Circuit, Overload Protection Overload Protection Current Consumption 90 mA max. 32 mA max. 60 mA max. 187 mA max. from Local Bus UL (mA) minal Current Consumption of US 8 Amp max 1 Amp (2 x 0.5A), LED Indicators Bus Diagstics Status Bus Diagstics Status Bus Diagstics Status Bus Diagstics Status indication of outputs indication of outputs indication of outputs indication of outputs Required Terminal Strip (4) IC220TBK123 (1) IC220TBK082 (1) IC220TBK085 (1) IC220TBK085 (Contains 10 strips) (Contains 10 strips) (Contains 10 strips) (Contains 10 strips) Requires Relay Isolation Set Requires Relay Isolation Set (IC220ACC201 and IC220TBK206) (IC220ACC201 and IC220TBK206) if switching voltages are t if switching voltages are t available in the segment. available in the segment. Artisan Techlogy Group - Quality Instrumentation ... Guaranteed VersaPoint 224 GE Fanuc Controller and I/O Solutions Analog input modules receive signals from current and voltage input devices. Specialty modules are available for RTD and Thermocouple inputs. Analog Input Modules shielded sensor cable shielded sensor cable shielded sensor cable shielded sensor cable Converter 120 micro seconds 10 micro seconds 120 micro seconds 120 micro seconds Module Update Rate Less than 1.5 msec Less than 0.8 to 1.3 msec 20 to 30 msec (depending 30 msec on connection method) Input Resistance Greater than 220 Kohm Greater than 240 Kohm (voltage) and 50 ohm (current) (voltage) and 25 ohm (current) Limit Frequency of the Input Filter 40 Hz 3.5 Hz 48 Hz Current Consumption 45 mA, typical 48 mA, typical 43 mA, typical 43 mA, typical for Local Bus UL (mA) minal Current Consumption of US LED Indicators Bus Diagstics Bus Diagstics Bus Diagstics Bus Diagstics Required Terminal Strip (1) IC220TBK062 (4) IC220TBK062 (1) IC220TBK062 (1) IC220TBK062 (Contains 5 strips) (Contains 5 strips) (Contains 5 strips) (Contains 5 strips) Artisan Techlogy Group - Quality Instrumentation ... Guaranteed VersaPoint GE Fanuc Controller and I/O Solutions 225 Analog output modules provide voltage or current signals to analog output devices. Analog Output Modules IC220ALG320 IC220ALG321 IC220ALG322 Product Name Analog Out 16 Bit Voltage/ Analog Out 16 Bit Voltage Analog Out 13 Bit Voltage minal Current Consumption of US LED Indicators Bus Diagstics, I/O Voltage for Bus Diagstics Bus Diagstics Default state set analog terminals present Required Terminal Strip (1) IC220TBK203 (Contains 1 strip) (1) IC220TBK061 (Contains 5 strips) (1) IC220TBK062 (Contains 5 strips) Artisan Techlogy Group - Quality Instrumentation ... Guaranteed VersaPoint 226 GE Fanuc Controller and I/O Solutions Motion modules enable the user to easily connect to high speed input devices. Motion Modules IC220MDD840 IC220MDD841 IC220MDD842 Product Name High Speed Counter input, Absolute Encoder input, 4 digital Incremental Encoder input, 4 digital 1 control input, 1 control output inputs and 4 digital outputs inputs and 4 digital outputs Number of Points 1 One SSI Encoder One A QUAD B Input Frequency 100Khz 400Khz Up to 500Khz Resolution 26 bit 26 bit Number of Inputs 144 Input Voltage 24 VDC/ 5 VDC 24 VDC 24 VDC Number of Outputs 144 Output Voltage 24 VDC, 500mA 24 VDC, 500mA 24 VDC, 500mA Connection Style Input: 2 and 3 wire Input: 2 and 3 wire Input: 2 and 3 wire Output: 2 wire Output: 2 and 3 wire Output: 2 and 3 wire Protection Short Circuit Protection Short Circuit Protection Short Circuit Protection Current Consumption 40 mA typical, 50 mA 60 mA 110 mA for Local Bus