MVME147RF工控机器人备件
220-HIM-A0 LCD显示器,全数字键盘,20-HIM-A3 LCD显示器,仅限Prograer,20-HIMA5增强型,LCD,全数字键区,防护等级IP66,NEMA 4X/12型,仅限室内使用。包括1202-C30接口电缆(3米/9.8英尺),用于连接驱动器。与PowerFlex Drive 70 753/755 AFE边框电缆套件(带连接器、工具和100米(328英尺)电缆1202-CBL-Kit 100M DPI电缆连接器套件1202-TB-Kit-SET DPI/SCANport)一起使用的人机交互模块(HIM)处理器说明™ 一对二端口分路器电缆1203-S03包括用于连接驱动器的1202-C30接口电缆(3 m/9.8 ft)。仅当HIM用作手持或远程时才需要重新调用。除20-HIM-H10外,还要求总最大距离为10 m(32.8 ft)。PowerFlex 7级和AFE选件空白板20-HIM-A3 20-HIM-A5 20-HIM-A6 20-HIM-C3S 20-HIM-C5S 20-HIM-C6S PowerFlex 7类和AFE选项罗克韦尔自动化出版物PFLEX-SG002I-EN-P-2015年5月91选项套件描述与PowerFlex Drive 70 753/755 AFE Bnet/IP选件模块20-750-BNETIP Bnet®MS/TP RS485适配器-B同轴选件套件电源20-XCO-PS1DPI外部套件20-XCO-BASE外部DPI I/O选项板20-XCO-IO-OPT1 pt I/O模块(3通道)1769-SM1需要一个载体卡(20-750-20CO或20-750-20CO-F1)。有关详细信息,请参阅PowerFlex 750系列腿部适配性。此物品具有银系列状态。仅用于DPI外部套件20-XCO-BASE。PowerFlex 7级和AFE选件92罗克韦尔自动化出版物PFLEX-SG002I-EN-P-2015年5月PowerFlex 750系列腿部适配性大多数腿部适配器()可与PowerFlex 753/755一起使用。但是,下列限制条件确实适用。框架1-建议20-750-20CO-F1载体卡只能安装在端口4中。安装此模块时,无法访问端口5。框架2及以上-建议将20-750-20CO载体卡安装在端口6中。使用端口4或5将使相邻的左侧端口不可用于其他选项模块,并可能干扰网线连接。适配器处理用于I/O连接的端口06(隐式和显式消息传递)处理端口7和更高版本(I/O、显式消息)支持驱动器附加组件支持亚洲语言类型-B Bnet MS/TP不兼容-C ControlNet发布时支持中文、日语和韩语。需要此适配器固件版本或更高版本。需要固件版本v1.05或更高版本的驱动器Add-on Profiles for Studio 5000 Logix Designer软件。控制器必须能够读取/写入32位浮点(REAL)值。支持所有三种操作模式(RTU、P1、N2)。此物品具有银系列状态。处理器说明与PowerFlex Drive 70 753/755 AFE串行零调制解调器适配器载体卡一起使用,用于PowerFlex 750系列机架2或更高版本的115V 11系列I/O模块,带有1个模拟输入、1个模拟输出、3个数字输入和2个继电器输出驱动器,只能协调一个选项。需要双增量编码器或通用Feedbk选项。还需要带有Frame 89驱动器的20-750-EMCSSM1-F8 EMC选件套件。Feedbk选项说明用于PowerFlex驱动编码器增量编码器20-750-ENC-1双增量编码器通用Feedbk(包括Stegmann、Heidenhain、SSI、Biss、5V增量)仅适用于PowerFlex 70增强控制。
0-HIM-A0 LCD Display, Full Numeric Keypad, 20-HIM-A3 LCD Display, Prograer Only, 20-HIM-A5 Enhanced, LCD, Full Numeric Keypad, emote IP66, NEMA Type 4X/12−for indoor use only. Includes a 1202-C30 interfe cable (3 m/9.8 ft) for connection to drive. Human Interfe Module (HIM) cessories Description Used with PowerFlex Drive 70 753/755 AFE Bezel Cable Kit with Connectors, Tools and 100 m (328 ft) Cable 1202-CBL-KIT-100M DPI Cable Connector Kit 1202-TB-KIT-SET DPI/SCANport™ One to Two Port Splitter Cable 1203-S03 Includes a 1202-C30 interfe cable (3 m/9.8 ft) for connection to drive. Requi only when HIM is used as handheld or remote. Requi in addition to 20-HIM-H10 for distances up to a total maximum of 10 m (32.8 ft). PowerFlex 7-Class and AFE Options Blank Plate 20-HIM-A3 20-HIM-A5 20-HIM-A6 20-HIM-C3S 20-HIM-C5S 20-HIM-C6S PowerFlex 7-Class and AFE Options Rockwell Automation Publication PFLEX-SG002I-EN-P - May 2015 91 Option Kits Description Used with PowerFlex Drive 70 753/755 AFE Bnet/IP Option Module 20-750-BNETIP Bnet® MS/TP RS485 Adapter -B Coaxial Option s Kit Power Supply 20-XCO--PS1 DPI External s Kit 20-XCO--BASE External DPI I/O Option Board 20-XCO-IO-OPT1 pt I/O Module (3 Channel) 1769-SM1 Requires a Carrier Card (20-750-20CO or 20-750-20CO-F1). Refer to PowerFlex 750-Series Legy patibility for details. This item has Silver Series status. For use only with DPI External s Kits 20-XCO--BASE. PowerFlex 7-Class and AFE Options 92 Rockwell Automation Publication PFLEX-SG002I-EN-P - May 2015 PowerFlex 750-Series Legy patibility Most legy adapters () can be used with the PowerFlex 753/755. However, the restrictions stated below do apply. Frame 1 - It is recoended that the 20-750-20CO-F1 Carrier Card only be installed in Port 4. Port 5 will not be cessible when this module is installed. Frames 2 and larger - It is recoended that the 20-750-20CO Carrier Card be installed in Port 6. Using Port 4 or 5 will make the adjent left port incessible to other option modules and may interfere with network cable connections. Adapter cesses Ports 06 for I/O Connections (Implicit and Explicit Messaging) cesses Ports 7 and Higher (I/O, Explicit Messaging) Supports Drive Add-on Profi les Supports AsianLanguages Type -B Bnet MS/TP Not patible -C ControlNet Chinese, Japanese, and Korean languages are supported at the time of publication. Requires this adapter fi rmware version or higher. Requires fi rmware version v1.05 or higher of the drive Add-on Profi les for Studio 5000 Logix Designer software. Controller must be capable of reading/writing 32-bit fl oating point (REAL) values. Supports all three modes of operation (RTU, P1, N2). This item has Silver Series status. cessories Description Used with PowerFlex Drive 70 753/755 AFE Serial Null Modem Adapter Carrier Card for PowerFlex 750-Series Frame 2 or higher drives 115V 11-Series I/O Module with 1 Analog In, 1 Analog Out, 3 Digital In and 2 Relay Outputs Drive can coodate only one option. Requires the Dual Incremental Encoder or Universal Feedbk Option. Also requires the 20-750-EMCSSM1-F8 EMC Option Kit with Frame 89 drives. Feedbk Options Description Used with PowerFlex Drive Encoder Incremental Encoder 20-750-ENC-1 Dual Incremental Encoder Universal Feedbk (includes Stegmann, Heidenhain, SSI, Biss, 5V Incremental Works only with PowerFlex 70 Enhanced Control.