MVME162-003工控备件模块
出版物A117-CA001A-EN-P!产品概述C型框架D型框架F型框架CMN型框架I型框架J型框架L型框架最大电流短路保护标准磁跳闸高磁跳闸仅限磁跳闸(MCP)过载保护跳闸等级UL 508附件。旋转操作器柔性电缆操作器辅助触点跳闸指示触点公告电机保护断路器和电机电路保护器2-43.ab./目录首选可用目录。编号为粗体。出版物A117-CA001A-EN-P!规格-C2TA16无需备份保险丝。IEC性能数据,续公告电机保护断路器和电机电路保护器2-44.ab./catalogs首选可用性类别。编号为粗体。出版物A117-CA001A-EN-P!规范IEC性能数据,续-D8T-F8TC16 C20 C25 C32额定工作电流,即标准三相电机的磁释放电流开关,无需熔断器。请咨询当地罗克韦尔自动化销售办公室或Allen-Bradley分销商。公告电机保护断路器和电机电路保护器2-45.ab./目录首选可用目录。编号为粗体。出版物A117-CA001A-EN-P!规范一般数据-C-D-F额定绝缘电压Ui IEC,SEV,VDE 0660[V]690 690 UL,CSA[V]600 600额定冲击耐受电压Uimp污染程度3 3主电路Uimp/过电压类别6 kV/III 6 kV/II辅助电路Uimp/过电压类型6 kV/IIII 6 kV/IV额定频率[Hz]50/60 4060使用类别IEC 60947-2(断路器)A IEC 60947-4-1(电机起动器)-3-3寿命机械[操作]开关频率[操作/h]最大值25最高20环境温度储存[°C]-40+80-25+80操作[°C]-25+60气候阻力湿度变化气候(600068-2-30)23°C/83%相对湿度和40°C/92%相对湿度,56个循环干热(60086-2-2)100°C,相对湿度<50%,7天湿热(40°C,相对湿度93%,56天现场海拔[m]至2000 N.N.防护等级IP2X,当具有抗冲击、运输(60068-2-27)30 g,11 ms,所有轴30,11 ms抗振动,操作(60068-2-6)5 g额定热电流Ith高达40°C环境温度环境温度[A]额定电源电流对温度的依赖性40°C[A]不吸液50°C[A]Ie过载保护章程IEC 60947-4-1电机保护(类别号-C2N、-D8N、-F8N除外)IEC 60947环境温度补偿[°C]-20+60相损耗保护差动释放跳闸等级10(类别号-C2N、-D8N、-F8N除外)固定设置10磁释放释放电流(+/-20%)固定设置1314 x Ie最大设置范围值固定设置14 x Ie在额定负载工作温度下最大总功率损耗Pv断路器[W]611.5 611.6 916 33主隔离开关应用是,带附件的应用条件对于北美以外的应用,(产品的)组件应符合IEC 61439-1的要求,手动电机起动器适用于没有粉尘、爆炸性或腐蚀性气体等危险操作条件的封闭区域。需要采用适当方式的外壳,以保护此类环境中的设备。公告电机保护断路器和电机电路保护器2-46.ab./目录首选可用目录。编号为粗体。出版物A117-CA001A-EN-P!公告电机保护断路器通用数据的规范附件,前安装的连续辅助控制块-C-AFA,右侧安装的C-AFAR辅助控制块C-ASA,-根据NEMA(UL/CSA标准)端子零件端子类型螺丝刀Pozidriv No。are bold. Publication A117-CA001A-EN-P ! Product Overview C-Frame D-Frame F-Frame CMN-Frame I-Frame J-Frame L-Frame Max. Current Short Circuit Protection Standard Magnetic Trip High Magnetic Trip Magnetic Only Trip (MCP) Overload Protection Trip Class UL 508 cessories Ext. Rotary Operator Flex Cable Operator Auxiliary Contts Trip Indication Contts Bulletin Motor Protection Circuit Breakers and Motor Circuit Protectors 2-43 .ab./catalogs Prefer availability cat. nos. are bold. Publication A117-CA001A-EN-P ! Specifications -C2TA16 No bk-up fuse requi. IEC Performance Data, Continued Bulletin Motor Protection Circuit Breakers and Motor Circuit Protectors 2-44 .ab./catalogs Prefer availability cat. nos. are bold. Publication A117-CA001A-EN-P ! Specifications IEC Performance Data, Continued -D8T- -F8TC16 C20 C25 C32 Rated Operational Current, Ie Magnetic Release Current Switching of Standard Three-Phase Motors No bk-up fuse requi. Consult your local Rockwell Automation sales office or Allen-Bradley distributor. Bulletin Motor Protection Circuit Breakers and Motor Circuit Protectors 2-45 .ab./catalogs Prefer availability cat. nos. are bold. Publication A117-CA001A-EN-P ! Specifications General Data -C -D -F Rated Insulation Voltage Ui IEC, SEV, VDE 0660 [V] 690 690 UL, CSA [V] 600 600 Rated Impulse Withstand Voltage Uimp Pollution degree 3 3 Main circuits Uimp /Overvoltage Category 6 kV/III 6 kV/III Auxiliary circuits Uimp /Overvoltage Category 6 kV/III 6 kV/III Rated Frequency [Hz] 50/60 4060 Utilization Category IEC 60947-2 (Circuit breaker) A A IEC 60947-4-1 (Motor starter) -3 -3 Life Span Mechanical [operations] Switching Frequency [operations/h] max. 25 max. 20 Ambient Temperature Storage [°C] -40 +80 -25 +80 Operation [°C] -25 +60 Climatic resistance Moisture change climate (600068-2-30) 23 °C / 83 % relative humidity and 40 °C / 92 % relative humidity, 56 cycles Dry heat (60086-2-2) 100 °C, relative humidity <50 %, 7 days Moisture heat ( 40 °C, relative humidity 93 %, 56 days Site Altitude [m] to 2000 N.N. Protection Class IP2X, when wi Resistance to Shock, Transport (60068-2-27) 30 g, 11 ms, all axes 30, 11 ms Resistance to Vibration, Opertion (60068-2-6) 5 g Rated Thermal Current Ith up to 40 °C ambient temperature ambient temperature [A] Rated Supply Current Dependence on Temperature 40 °C [A] no uction 50 °C [A] no uction no uction current uction of the upper rated current Ie Overload Protection Charteristics IEC 60947-4-1 Motor protection (except Cat. Nos. -C2N, -D8N, -F8N) IEC 60947 Ambient Temperature pensation [°C] -20 +60 Phase-loss Protection Differential release Trip class 10 (except Cat. Nos. -C2N, -D8N, -F8N) fixed setting 10 Magnetic Release Release current (+/-20 %) fixed setting 1314 x Ie max. values of setting ranges fixed setting 14 x Ie max. Total Power loss Pv Circuit Breaker at rated load operating temperature [W] 611.5 611.6 916 33 Main Disconnect Switch Application Yes, with cessories Application Conditions For utilization outside North America, assemblies (of products) shall ply to the IEC 61439-1 requirements manual motor starters are intended for use in closed areas without hazardous operating conditions such as dust or explosive or corrosive gases. Enclosures of appropriate manner need to be in ple to protect devices in such environments. Bulletin Motor Protection Circuit Breakers and Motor Circuit Protectors 2-46 .ab./catalogs Prefer availability cat. nos. are bold. Publication A117-CA001A-EN-P ! Specifications cessories for Bulletin Motor Protection Circuit Breakers General Data, Continued Auxiliary Contt Blocks for Front Mounting -C-AFA, -C-AFAR Auxiliary Contt Blocks for Right-Side Mounting -C-ASA, -C-ASAR Rated Thermal Current Ith at 40 °C ambient temperature at 60 °C ambient temperature Contt Class Coordination cording to NEMA (UL/CSA Standards) Terminal Parts Type of terminals Screwdriver Pozidriv No.