MVME162-010A工控备件,工控备件机器人模块
有关电机保护断路器正确应用的更多详细信息,请参阅以下页面的图表。IEC/EN 60947-1、-2、-4-1、5-1 IEC/EN 60204-1认证ATEX产品概述公告电机保护断路器2-3.ab./目录首选可用性类别。编号为粗体。出版物A117-CA001A-EN-P!产品概述C型框架D型框架F型框架CMN型框架I型框架J型框架L型框架最大电流短路保护标准磁跳闸高磁跳闸仅限磁跳闸(MCP)过载保护跳闸等级UL 508附件。旋转操作器柔性电缆操作器辅助触点跳闸指示触点公告电机保护断路器和电机电路保护器2-43.ab./目录首选可用目录。编号为粗体。出版物A117-CA001A-EN-P!规格-C2TA16无需备份保险丝。IEC性能数据,续公告电机保护断路器和电机电路保护器2-44.ab./catalogs首选可用性类别。编号为粗体。出版物A117-CA001A-EN-P!规范IEC性能数据,续-D8T-F8TC16 C20 C25 C32额定工作电流,即标准三相电机的磁释放电流开关,无需熔断器。请咨询当地罗克韦尔自动化销售办公室或Allen-Bradley分销商。公告电机保护断路器和电机电路保护器2-45.ab./目录首选可用目录。编号为粗体。出版物A117-CA001A-EN-P!规范一般数据-C-D-F额定绝缘电压Ui IEC,SEV,VDE 0660[V]690 690 UL,CSA[V]600 600额定冲击耐受电压Uimp污染程度3 3主电路Uimp/过电压类别6 kV/III 6 kV/II辅助电路Uimp/过电压类型6 kV/IIII 6 kV/IV额定频率[Hz]50/60 4060使用类别IEC 60947-2(断路器)A IEC 60947-4-1(电机起动器)-3-3寿命机械[操作]开关频率[操作/h]最大值25最高20环境温度储存[°C]-40+80-25+80操作[°C]-25+60气候阻力湿度变化气候(600068-2-30)23°C/83%相对湿度和40°C/92%相对湿度,56个循环干热(60086-2-2)100°C,相对湿度<50%,7天湿热(40°C,湿度93%,56天现场海拔[m]至2000 N.N。防护等级IP2X,当具有耐冲击性时,运输(60068-2-27)30 g,11 ms,所有轴30,11 ms耐振动,操作(60068-2-6)5 g额定热电流Ith高达40°C
For further details on the proper application of Motor Protection Circuit Breakers, please see the diagrams on the following pages. IEC/EN 60947-1, -2, -4-1, -5-1 IEC/EN 60204-1 Certified ATEX Product Overview Bulletin Motor Protection Circuit Breakers 2-3 .ab./catalogs Prefer availability cat. nos. are bold. Publication A117-CA001A-EN-P ! Product Overview C-Frame D-Frame F-Frame CMN-Frame I-Frame J-Frame L-Frame Max. Current Short Circuit Protection Standard Magnetic Trip High Magnetic Trip Magnetic Only Trip (MCP) Overload Protection Trip Class UL 508 cessories Ext. Rotary Operator Flex Cable Operator Auxiliary Contts Trip Indication Contts Bulletin Motor Protection Circuit Breakers and Motor Circuit Protectors 2-43 .ab./catalogs Prefer availability cat. nos. are bold. Publication A117-CA001A-EN-P ! Specifications -C2TA16 No bk-up fuse requi. IEC Performance Data, Continued Bulletin Motor Protection Circuit Breakers and Motor Circuit Protectors 2-44 .ab./catalogs Prefer availability cat. nos. are bold. Publication A117-CA001A-EN-P ! Specifications IEC Performance Data, Continued -D8T- -F8TC16 C20 C25 C32 Rated Operational Current, Ie Magnetic Release Current Switching of Standard Three-Phase Motors No bk-up fuse requi. Consult your local Rockwell Automation sales office or Allen-Bradley distributor. Bulletin Motor Protection Circuit Breakers and Motor Circuit Protectors 2-45 .ab./catalogs Prefer availability cat. nos. are bold. Publication A117-CA001A-EN-P ! Specifications General Data -C -D -F Rated Insulation Voltage Ui IEC, SEV, VDE 0660 [V] 690 690 UL, CSA [V] 600 600 Rated Impulse Withstand Voltage Uimp Pollution degree 3 3 Main circuits Uimp /Overvoltage Category 6 kV/III 6 kV/III Auxiliary circuits Uimp /Overvoltage Category 6 kV/III 6 kV/III Rated Frequency [Hz] 50/60 4060 Utilization Category IEC 60947-2 (Circuit breaker) A A IEC 60947-4-1 (Motor starter) -3 -3 Life Span Mechanical [operations] Switching Frequency [operations/h] max. 25 max. 20 Ambient Temperature Storage [°C] -40 +80 -25 +80 Operation [°C] -25 +60 Climatic resistance Moisture change climate (600068-2-30) 23 °C / 83 % relative humidity and 40 °C / 92 % relative humidity, 56 cycles Dry heat (60086-2-2) 100 °C, relative humidity <50 %, 7 days Moisture heat ( 40 °C, relative humidity 93 %, 56 days Site Altitude [m] to 2000 N.N. Protection Class IP2X, when wi Resistance to Shock, Transport (60068-2-27) 30 g, 11 ms, all axes 30, 11 ms Resistance to Vibration, Opertion (60068-2-6) 5 g Rated Thermal Current Ith up to 40 °C