MVME167-033A工控模块备件
湿度IEC 60068-2-30(试验D未包装湿热)5…95%压缩振动IEC 60068-2-6(试验F运行)2 g@10…500 Hz Shoc运行IEC 60068-2-27(试验E未包装冲击)30 g Shoc运行(试验E不包装冲击)50 g排放CISPR 11第1组,A级ESD抗扰度IEC 61000-4-2 6 kV接触放电8 kV空气放电辐射射频抗扰度IEC61000-4-3 10Vm,1 kHz正弦波80%AM,来自80…2000 MHz 10Vm,200 Hz 50%脉冲100%AM@900 MHz 10Vm和200 Hz 50%脉动100%AM@1890 MHz 3Vm,1 Hz正弦波80%AM来自2000…2700 MHz表31-认证-1784存储卡认证见产品认证链接:www.ab.com,获取符合性声明、证书和其他认证详情。1784-CF1281784-SD1、1784-SD2 CE欧盟2004108EC EMC指令,符合:EN 61000-6-4;工业排放EN 61326-1;测量控制实验室。,工业要求EN 61000-6-2;工业抗扰度EN 61131-2;可编程控制器(第8条,A区和B区)C-Tick澳大利亚无线电通信Ac符合:AS/NZS CISPR 11;工业排放KC韩国广播和通信设备注册符合:无线电波Ac第3条30罗克韦尔自动化出版物1756-TD001G-EN-P第58-2条-2013年1月1756 ControlLogix控制器1756储能模块代替电池,1756-L7x和1756-L7xS控制器随已安装的1756-ESMCAP能量存储模块(ESM)一起提供。表32-技术规范-1756储能模块属性1756-ESMCAP 1756-ESMNSE 1756-ESMNRM描述电容器储能模块(可拆卸,随每个控制器一起装运)。电容器储能模块(可拆卸的剩余WallClockTime备用电源)。如果应用程序要求安装的ESM在将其运入或运出应用程序之前将其剩余能量消耗至40µJ或更低,请使用此ESM。此外,您只能将此ESM与1756-L73(8MB)或更小的内存大小控制器一起使用。在移除ESM之前,至少等待20分钟,使剩余存储能量降至40µJ或更低。电容器储能模块(不可移动,通过防止USB连接和SD卡使用来保护控制器)。如果在插入1756-ESMNRM模块之前安装了SD卡,则SD卡仍能正常工作,但无法移除。此ESM为您的应用程序提供了增强的安全性。电流消耗@5.1V DC 330 mA 300 mA 330 mA美国温度代码T4A IEC温度代码T4外壳类型额定值ne(开放式)表33-环境规范-1756储能模块属性1756-ESMCA 1756-ESMNSE,1756-ESMNRM温度,运行IEC 60068-2-1(测试A运行低温),IEC 60068-2-2(测试B运行干热),IEC 60068-2-14(试验N工作热冲击)0…60°C(32…140°F,最高60°C(140°F)相对湿度IEC 60068-2-30(试验D未包装湿热)5…95%压缩振动IEC 60068-2-6(试验F运行)2 g@10…500 Hz Shoc运行IEC 60068-2-27(试验E未包装冲击)30 g Shoc运行的IEC 60068-227(试验E不包装冲击)50 g罗克韦尔自动化出版物1756-TD001G-EN-P-2013年1月31日1756 ControlLogix控制器排放CISPR 11第1组,A级ESD抗扰度IEC 61000-4-2 6 kV接触放电8 kV空气放电辐射射频抗扰度IEC61000-4-3 10Vm,1 kHz正弦波80%AM,来自80…2000 MHz 10Vm,200 Hz 50%脉冲100%AM@900 MHz 10Vm和200 Hz 50%脉动100%AM@1890 MHz 3Vm,1 Hz正弦波80%AM来自2000…2700 MHz表34-认证-1756储能模块认证见产品认证链接:www.ab.com,获取符合性声明、证书和其他认证详情。1756-ESMCA 1756-ESMNSE、1756-ESMNRM c-UL-us UL认证的工业控制设备,适用于美国和加拿大。
humidity IEC 60068-2-30 (Test D Unpackaged Damp Heat) 5…95% ncondensing Vibration IEC 60068-2-6 (Test F Operating) 2 g @ 10…500 Hz Shoc operating IEC 60068-2-27 (Test E Unpackaged Shock) 30 g Shoc perating IEC 60068-2-27 (Test E Unpackaged Shock) 50 g Emissions CISPR 11 Group 1, Class A ESD immunity IEC 61000-4-2 6 kV contact discharges 8 kV air discharges Radiated RF immunity IEC 61000-4-3 10Vm with 1 kHz sine-wave 80% AM from 80…2000 MHz 10Vm with 200 Hz 50% Pulse 100% AM @ 900 MHz 10Vm with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3Vm with 1 kHz sine-wave 80% AM from 2000…2700 MHz Table 31 - Certifications - 1784 Memory Cards Certification See the Product Certification link at http:www.ab.com for Declarations of Conformity, Certificate and other certification details. 1784-CF128, 1784-SD1, 1784-SD2 CE European Union 2004108EC EMC Directive, compliant with: EN 61000-6-4; Industrial Emissions EN 61326-1; Meas.ControlLab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radio communications Ac compliant with: ASNZS CISPR 11; Industrial Emissions KC Korean Registration of Broadcasting and Communications Equipmen compliant with: Article 58-2 of Radio Waves Ac Clause 3 30 Rockwell Automation Publication 1756-TD001G-EN-P - January 2013 1756 ControlLogix Controllers 1756 Energy Storage Modules Instead of a battery, the 1756-L7x and 1756-L7xS controllers are shipped with a 1756-ESMCAP energy storage module (ESM) already installed. Table 32 - Technical Specifications - 1756 Energy Storage Modules Attribute 1756-ESMCAP 1756-ESMNSE 1756-ESMNRM Description Capacitor energy storage module (removable, ships installed with every controller). Capacitor energy storage module (removable, residual WallClockTime power backup). Use this ESM if your application requires that the installed ESM deplete its residual energy to 40 µJ or less before transporting it into or out of your application. Additionally, you can use this ESM with a 1756-L73 (8 MB) or smaller memory-sized controller only. Wait at least 20 minutes for the residual stored energy to decrease to 40 µJ or less before you remove the ESM. Capacitor energy storage module (nremovable, secures controller by preventing USB connection an d SD card use). If the SD card is installed prior to insertion of the 1756-ESMNRM module, the SD card remains functiona but t removable. This ESM provides your application an enhanced degree of security. Current draw @ 5.1V DC 330 mA 300 mA 330 mA rth American temperature code T4A IEC temperature code T4 Enclosure type rating ne (open-style) Table 33 - Environmental Specifications - 1756 Energy Storage Modules Attribute 1756-ESMCA 1756-ESMNSE, 1756-ESMNRM Temperature, operating IEC 60068-2-1 (Test A Operating Cold), IEC 60068-2-2 (Test B Operating Dry Heat), IEC 60068-2-14 (Test N Operating Thermal Shock) 0…60 °C (32…140 °F) Temperature, perating IEC 60068-2-1 (Test A Unpackaged perating Cold), IEC 60068-2-2 (Test B Unpackaged perating Dry Heat), IEC 60068-2-14 (Test N Unpackaged perating Thermal Shock) -40…85 °C (-40…185 °F) Temperature, surrounding air, max 60 °C (140 °F) Relative humidity IEC 60068-2-30 (Test D Unpackaged Damp Heat) 5…95% ncondensing Vibration IEC 60068-2-6 (Test F Operating) 2 g @ 10 …500 Hz Shoc operating IEC 60068-2-27 (Test E Unpackaged Shock) 30 g Shoc perating IEC 60068-2-27 (Test E Unpackaged Shock) 50 g Rockwell Automation Publication 1756-TD001G-EN-P - January 2013 31 1756 ControlLogix Controllers Emissions CISPR 11 Group 1, Class A ESD immunity IEC 61000-4-2 6 kV contact discharges 8 kV air discharges Radiated RF immunity IEC 61000-4-3 10Vm with 1 kHz sine-wave 80% AM from 80…2000 MHz 10Vm with 200 Hz 50% Pulse 100% AM @ 900 MHz 10Vm with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3Vm with 1 kHz sine-wave 80% AM from 2000…2700 MHz Table 34 - Certifications - 1756 Energy Storage Modules Certification See the Product Certification link at http:www.ab.com for Declarations of Conformity, Certificate and other certification details. 1756-ESMCA 1756-ESMNSE, 1756-ESMNRM c-UL-us UL Listed Industrial Control Equipmen certified for US and Canada.