MVME167-034A系统备件
--25…70°C(-13…158°F)温度,储存IEC 60068-2-1(试验A未包装工作冷),IEC 60068-2-2(试验B未包装工作干热),IEC 6008-2-14(试验N未包装工作热冲击)-40…85°C(-40…185°F)周围空气温度,最高60°C(140°F)70°C(158°F)相对湿度IEC 60068-2-30(试验D未包装湿热)5…95%压缩振动IEC 60068-2-6(试验F运行)2 g@10…500 Hz 26罗克韦尔自动化出版物1756-TD001G-EN-P-2013年1月1756 ControlLogix控制器运行IEC 60068-2-27(试验E未包装冲击)30 g运行IEC 60068-27(试验E非包装冲击)50g排放CISPR 11 IEC 61000-6-4第1组,A类A类第1组,A类A类ESD抗扰度IEC 61000-4-2 6 kV接触放电8 kV空气放电辐射射频抗扰度IEC61000-4-3 10Vm,1 kHz正弦波80%AM,从80…2000 MHz 10Vm,200 Hz 50%脉冲100%AM@900 MHz 10Vm和200 Hz 50%脉动100%AM@1890 MHz 3Vm,1 Hz正弦波80%AM(从2000…2700 MHz)表26-认证-1756冗余模块认证1756-RM1756-RMXT 1756-RM2 1756-RM2XT CSA认证过程控制设备。参见CSA文件LR54689C。CSA认证的过程控制设备,适用于2类D组危险场所。参见CSA文件LR69960CCSA认证的过程控制设备。参见CSA文件LR54689C。CSA认证的过程控制设备,适用于2类D组危险场所。参见CSA文件LR69960CCE欧盟2004108IEC EMC指令,符合:EN 61326-1;测量控制实验室。,工业要求EN 61000-6-2;工业抗扰度EN 61000-6-4;工业排放EN 61131-2;可编程控制器(第8条,A区和B区)C-Tick澳大利亚无线电通信Ac符合:AS/NZS CISPR 11;工业排放c-UL-us经UL认证的工业控制设备,适用于美国和加拿大。参见UL文件E65584。UL列出了经美国和加拿大认证的2类D组危险场所。参见UL文件E194810。Ex EU 949EC ATEX指令,符合:EN 60079-15;潜在爆炸性环境保护“n”EN 60079-0;一般要求II 3 G Ex nA IIC T4 X Gc FM FM认证设备,适用于I类2类D组危险场所-FM认证设备适用于I级2类D类危险场所-KC韩国广播和通信设备注册符合:无线电波Ac第3条第58-2条。有关符合性声明、证书和其他认证详细信息,请参见产品认证链接:www.ab.com。表25-环境规范-1756冗余模块(续)属性1756-RM 1756-RM2 1756-RMXT 1756-RM2XT罗克韦尔自动化出版物1756-TD001G-EN-P-2013年1月27日1756 ControlLogix控制器ControlLogix连接ControlLogix系统使用连接在设备之间建立通信链路。连接类型包括:控制器至本地IO模块或本地通信模块控制器至远程IO或远程通信模块控制器到远程IO(机架优化)模块生成和消耗的标签信息通过控制器编程软件访问通过RSLinx®软件访问HMI或其他应用程序您间接确定控制器通过配置控制器与系统中的其他设备通信而使用的连接。连接的限制最终可能存在于用于连接的通信模块中。如果消息路径路由通过通信模块,则与消息相关的连接也计入该通信模块的连接限制。1756-L6x和1756-L6xS控制器支持250个连接;1756-L7x和1756-L7xS控制器支持500。
25…70 °C (-13…158 °F) Temperature, storage IEC 60068-2-1 (Test A Unpackaged perating Cold), IEC 60068-2-2 (Test B Unpackaged perating Dry Heat), IEC 60068-2-14 (Test N Unpackaged perating Thermal Shock) -40…85 °C (-40…185 °F) Temperature, surrounding air, max 60 °C (140 °F) 70 °C (158 °F) Relative humidity IEC 60068-2-30 (Test D Unpackaged Damp Heat) 5…95% ncondensing Vibration IEC 60068-2-6 (Test F Operating) 2 g @ 10…500 Hz 26 Rockwell Automation Publication 1756-TD001G-EN-P - January 2013 1756 ControlLogix Controllers Shoc operating IEC 60068-2-27 (Test E Unpackaged Shock) 30 g Shoc perating IEC 60068-2-27 (Test E Unpackaged Shock) 50 g Emissions CISPR 11 IEC 61000-6-4 Group 1, Class A Class A Group 1, Class A Class A ESD immunity IEC 61000-4-2 6 kV contact discharges 8 kV air discharges Radiated RF immunity IEC 61000-4-3 10Vm with 1 kHz sine-wave 80% AM from 80…2000 MHz 10Vm with 200 Hz 50% Pulse 100% AM @ 900 MHz 10Vm with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3Vm with 1 kHz sine-wave 80% AM from 2000…2700 MHz Table 26 - Certifications - 1756 Redundancy Module Certification 1756-RM 1756-RMXT 1756-RM2 1756-RM2XT CSA CSA Certified Process Control Equipment. See CSA File LR54689C. CSA Certified Process Control Equipment for Class Division 2 Group D Hazardous Locations. See CSA File LR69960C. — CSA Certified Process Control Equipment. See CSA File LR54689C. CSA Certified Process Control Equipment for Class Division 2 Group D Hazardous Locations. See CSA File LR69960C. — CE European Union 2004108IEC EMC Directive, compliant with: EN 61326-1; Meas.ControlLab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radio communications Ac compliant with: ASNZS CISPR 11; Industrial Emissions c-UL-us UL Listed Industrial Control Equipmen certified for U.S. and Canada. See UL file E65584. UL Listed for Class Division 2 Group D Hazardous Location certified for U.S. and Canada. See UL File E194810. Ex European Union 949EC ATEX Directive, compliant with: EN 60079-15; Potentially Explosive Atmosphere Protection “n” EN 60079-0; General Requirements II 3 G Ex nA IIC T4 X Gc FM FM Approved Equipment for use in Class I Division 2 Group D Hazardous Locations — FM Approved Equipment for use in Class I Division 2 Group D Hazardous Locations — KC Korean Registration of Broadcasting and Communications Equipmen compliant with: Article 58-2 of Radio Waves Ac Clause 3 When marked. See the Product Certification link at http:www.ab.com for Declarations of Conformity, Certificate and other certification details. Table 25 - Environmental Specifications - 1756 Redundancy Module (continued) Attribute 1756-RM 1756-RM2 1756-RMXT 1756-RM2XT Rockwell Automation Publication 1756-TD001G-EN-P - January 2013 27 1756 ControlLogix Controllers ControlLogix Connections A ControlLogix system uses connections to establish communication links between devices. The types of connections include the following: Controller-to-local IO modules or local communication modules Controller-to-remote IO or remote communication modules Controller-to-remote IO (rack-optimized) modules Produced and consumed tags Messages Access via the controller programming software Access via RSLinx® software for HMI or other applications You indirectly determine the number of connections the controller uses by configuring the controller to communicate with other devices in the system. The limit of connections may ultimately reside in the communication module you use for the connection. If a message path routes through a communication module, the connection related to the message also counts towards the connection limit of that communication module. The 1756-L6x and 1756-L6xS controllers support 250 connections; the 1756-L7x and 1756-L7xS controllers support 500.