MVME167A工控备件机器人模块
导线类别使用此导线类别信息规划导线布线。参考工业布线和接地指南出版物1770-4.1.3-关于USB端口北美温度代码T4A IEC温度代码T4外壳类型额定值无(开放式)罗克韦尔自动化出版物1756-TD001G-EN-P-2013年1月15日1756 ControlLogix控制器表16-环境规范-1756-L7x GuardLogix控制器属性1756-L71 1756-L72 1756-L731756-L7SP温度,运行IEC 60068-2-1(测试A运行冷)、IEC 60068-2-2(测试B运行干热)、IEC 6008-2-14(测试N运行热冲击)0…60°C(32…140°F)温度,非运行IEC 60068-2-1(测试B非运行冷),IEC 60068-2-14(试验N未包装非操作热冲击)-40…85°C(-40…185°F)相对湿度IEC 60068-2-30(试验D未包装湿热)5…95%非冷凝温度,周围空气,最高60°C(140°F)振动IEC 60068-2-6(测试F运行)2 g@10…500 Hz Shoc运行IEC 60068-2-27(测试E开箱冲击)30 g Shoc未运行IEC 60068-27(测试E未开箱冲击)50 g(安装SD卡时45 g)发射CISPR 11 IEC 61000-6-4 A级ESD抗扰度IEC 61000-4-2 6 kV接触放电8 kV空气放电辐射射频抗扰度80…2000 MHz 10Vm的kHz正弦波80%AM,200 Hz 50%脉冲100%AM@900 MHz 10Vm,200 Hz 50%脉冲100%AM@1890 MHz 3Vm,2000…2700 MHz的1kHz正弦波80%AM表17-认证-1756-L7xS GuardLogix控制器认证标记时。有关符合性声明、证书和其他认证详细信息,请参见产品认证链接:www.ab.com。1756-L71 1756-L72 1756-L73 1756-L7SP c-UL-us UL认证工业控制设备,适用于美国和加拿大。参见UL文件E65584。UL列出了经美国和加拿大认证的2类D组危险场所。参见UL文件E194810.CE欧盟2004108EC EMC指令,符合:EN 61000-6-4;工业排放EN 61326-1;测量控制实验室。,工业要求EN 61000-6-2;工业抗扰度EN 61131-2;可编程控制器(第8条,A区和B区)欧盟200642EC M符合:EN 60204-1;机器电气设备EN ISO 13849-1;控制系统的安全相关部件EN 62061;安全相关控制系统的功能安全C-Tick澳大利亚无线电通信Ac符合:AS/NZS CISPR 11;工业排放Ex EU 949EC ATEX指令,符合:EN 60079-15;潜在爆炸性环境保护“n”EN 60079-0;一般要求II 3 G Ex nA IIC T4 X KC韩国广播和通信设备注册符合:无线电波Ac第3条TÜV第58-2条的功能安全认证当与指定的固件版本一起使用时。符合IEC 61508的SIL CL 3,符合EN954-1的4类,当按照GuardLogix控制器系统安全参考手册出版物1756-RM093.16罗克韦尔自动化出版物1756-TD001G-EN-P-2013年1月1756 ControlLogix控制器1756-L6xS GuardLogox控制器规范表18-技术规范-1756-L6x S GuardLogo控制器属性1756-L61S 1756-L62S中的描述使用时,能够根据ISO 13849-1进行PL(e)1756-L63S 1756-LSP用户内存2 MB 4 MB 8 MB-安全内存1 MB 1 MB 3.75 MB与相应的主控制器IO内存478 KB相同-可选非易失性内存存储128 MB(1784-CF128)1 GB(1784-SD1,随每个控制器提供)2 GB(1784-SD2)RSLogix™ 5000编程软件,版本18或更高。-数字I max 128000--模拟I max 4000总I max 1280000更换电池1756-BA2(0.50 g锂)储能模块
Wire category Use this Conductor Category information for planning conductor routing. Refer to Industrial Wiring and Grounding Guideline publication 1770-4.1. 3 - on USB ports North American temperature code T4A IEC temperature code T4 Enclosure type rating None (open-style) Rockwell Automation Publication 1756-TD001G-EN-P - January 2013 15 1756 ControlLogix Controllers Table 16 - Environmental Specifications - 1756-L7x GuardLogix Controllers Attribute 1756-L71 1756-L72 1756-L73 1756-L7SP Temperature, operating IEC 60068-2-1 (Test A Operating Cold), IEC 60068-2-2 (Test B Operating Dry Heat), IEC 60068-2-14 (Test N Operating Thermal Shock) 0…60 °C (32…140 °F) Temperature, nonoperating IEC 60068-2-1 (Test A Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test B Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test N Unpackaged Nonoperating Thermal Shock) -40…85 °C (-40…185 °F) Relative humidity IEC 60068-2-30 (Test D Unpackaged Damp Heat) 5…95% noncondensing Temperature, surrounding air, max 60 °C (140 °F) Vibration IEC 60068-2-6 (Test F Operating) 2 g @ 10…500 Hz Shoc operating IEC 60068-2-27 (Test E Unpackaged Shock) 30 g Shoc nonoperating IEC 60068-2-27 (Test E Unpackaged Shock) 50 g (45 g with SD card installed) Emissions CISPR 11 IEC 61000-6-4 Class A ESD immunity IEC 61000-4-2 6 kV contact discharges 8 kV air discharges Radiated RF immunity IEC 61000-4-3 10Vm with 1 kHz sine-wave 80% AM from 80…2000 MHz 10Vm with 200 Hz 50% Pulse 100% AM @ 900 MHz 10Vm with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3Vm with 1 kHz sine-wave 80% AM from 2000…2700 MHz Table 17 - Certifications - 1756-L7xS GuardLogix Controllers Certification When marked. See the Product Certification link at http:www.ab.com for Declarations of Conformity, Certificate and other certification details. 1756-L71 1756-L72 1756-L73 1756-L7SP c-UL-us UL Listed Industrial Control Equipmen certified for US and Canada. See UL File E65584. UL Listed for Class Division 2 Group D Hazardous Location certified for U.S. and Canada. See UL File E194810. CE European Union 2004108EC EMC Directive, compliant with: EN 61000-6-4; Industrial Emissions EN 61326-1; Meas.ControlLab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 200642EC M compliant with: EN 60204-1; Electrical equipment of machines EN ISO 13849-1; Safety-related parts of control systems EN 62061; Functional safety of safety-related control systems C-Tick Australian Radio communications Ac compliant with: ASNZS CISPR 11; Industrial Emissions Ex European Union 949EC ATEX Directive, compliant with: EN 60079-15; Potentially Explosive Atmosphere Protection ’n’ EN 60079-0; General Requirements II 3 G Ex nA IIC T4 X KC Korean Registration of Broadcasting and Communications Equipmen compliant with: Article 58-2 of Radio Waves Ac Clause 3 TÜV certified for functional safety When used with specified firmware revisions. Capable of SIL CL 3 according to IEC 61508, capable of Category 4 according to EN954-1, and capable of PL(e) according to ISO 13849-1 when used as described in the GuardLogix Controller Systems Safety Reference Manua publication 1756-RM093. 16 Rockwell Automation Publication 1756-TD001G-EN-P - January 2013 1756 ControlLogix Controllers 1756-L6xS GuardLogix Controllers Specifications Table 18 - Technical Specifications - 1756-L6xS GuardLogix Controllers Attribute 1756-L61S 1756-L62S 1756-L63S 1756-LSP User memory 2 MB 4 MB 8 MB — Safety memory 1 MB 1 MB 3.75 MB Same as corresponding primary controller IO memory 478 KB — Optional nonvolatile memory storage 128 MB (1784-CF128) 1 GB (1784-SD1, ships with every controller) 2 GB (1784-SD2) RSLogix™ 5000 programming software, version 18 or later. — Digital I max 128,000 — — — Analog I max 4000 Total I max 128,000 Replacement battery 1756-BA2 (0.50 g lithium) Energy storage modules