MVME172-363备件模块
在手动复位N/A N/A模式(M)下,必须连接复位按钮外壳D=75mm D=143mm D=120mm H=180mm H=230mm H=73mm W=130mm W=210mm W=152mm 32路导轨重量880g 3200g 920g 10传感器垫传感器垫符合EN 1760-1,EN954-1:类别1,UL 508有保证检测的人的最小重量:35Kg最大检测区域:100m2单个垫的最大数量:无限制(最多100m2)连接线的最大总长度:200m质量/m2(传感器垫):24Kg环境保护垫:IP67机械寿命:1 x 106操作湿度:0-100%RH传感器垫外层材料:乙烯基标准颜色:黄色工作温度范围-10°C至+55°C存储温度范围-40°C至+70°C由互连传感器垫和控制单元组成的系统符合EN 954-1第3类的要求。11控制单元440F-C28013电源24V AC/DC或110/230V可选继电器输出2 x独立无电压N/O安全触点1 x独立无压N/C监控触点1 x免费N/C辅助触点1 x V免费N/O辅助触点安全输入8 x 4带模制Allen-Bradley连接器的线垫指示灯LED 1电源绿色LED 2手动复位模式绿色LED 3自动复位模式绿色LED4机器启用绿色LED 5-12信道故障状态绿色/红色端子减去与PCB成45°安装的M2.5端子螺钉注:适用于所有其他规格和尺寸详情请参考440F-C4000S控制单元。图7显示检测区的周边修剪和联合修剪详图。有关机器接口的指导,请参阅第5节。
有关固定和互连安排的详细信息,请参阅6节。周边修剪主动装置修剪传感器垫检测区每个周边修剪增加52mm(NZG 3010)每个联合修剪接头增加10mm标称垫尺寸每个周边修剪(NZG 301 1)增加95mm 6 x 3/8”自攻螺钉(未提供)12图8尺寸单位为使用盖子底部的固定孔13聚碳酸酯外壳440F-C4000P钢外壳440F-C4 000S和440F-C28013 DIN导轨外壳440F-C4000D第5节-安装设计开始安装前,应完整阅读本手册。建议装置只能由电气和机械工程方面具有适当能力并具有安全相关控制系统设计经验的人员设计。许多因素有助于安全可靠的安装。通过以下步骤的工作,将确保不会忽略任何内容,并且可以以最小的麻烦和最大的信心规划和实施安装。所遵循的程序细节基于欧洲最佳实践,并符合欧盟机械指令。即使这些要求不适用于您的安装,我们建议您遵循相同的步骤,但修改细节以符合相关法定要求或实践规范(例如ANSI、OSHA)。5.1危险的性质当操作员在危险附近时,该系统可通过隔离电源消除危险。需要采取额外措施来处理风险评估中确定的其他危险(例如零件喷射、热表面等)。这些措施可能包括固定防护装置、联锁防护装置、警告通知等。如果需要,请联系供应商获取更多信息。注:风险评估包含在EN 291-1中,并在EN 1050.5.2安全保护性质中详细说明。系统设计必须满足三个主要要求:1.如果有人能够进入危险区域,则必须停止机器。2.在接近人员能够进入危险区域之前,机器必须停止。3.不得轻易绕过系统。建议使用垫子系统,可在可能进入危险区域的整个区域进行存在感测。(参见图9中的示例)。不建议将垫子系统用于其他用途,例如,仅用作周界门禁或机器启用装置。如果您正在考虑将垫子系统用于本手册未涵盖的任何应用,请联系供应商。
Under the manual reset N/A N/A mode (M), the reset button shell must be connected D=75mm D=143mm D=120mm H=180mm H=230mm H=73mm W=130mm W=152mm 32 way guide rail weight 880g 3200g 920g 10 sensor pad The sensor pad complies with EN 1760-1, EN954-1: Category 1, UL 508 Minimum weight of the person who can guarantee the detection: 35Kg Maximum detection area: 100m2 Maximum number of single pads: unlimited (maximum 100m2) Maximum total length of the connecting line: 200m mass/m2 (sensor pads) : 24Kg environmental protection pad: IP67 Mechanical life: 1 x 106 Operating humidity: 0-100% RH Sensor pad Outer layer material: vinyl standard color: yellow Operating temperature range - 10 ° C to+55 ° C Storage temperature range - 40 ° C to+70 ° C The system consisting of interconnected sensor pads and control units complies with the requirements of EN 954-1 Category 3. 11 Control unit 440F-C28013 power supply 24V AC/DC or 110/230V optional relay output 2 x independent voltage free N/O safety contact 1 x independent voltage free N/C monitoring contact 1 x free N/C auxiliary contact 1 x V free N/O auxiliary contact safety input 8 x 4 wire pad indicator LED 1 power supply green LED 2 manual reset mode green LED 3 automatic reset mode green LED 4 machine enable green LED 5-12 channel fault state green/red terminal minus M2.5 terminal screw mounted at 45 ° to PCB Note: applicable to all other specifications and dimensions. Please refer to 440F-C4000S control unit for details. Figure 7 shows the peripheral trim and joint trim details of the detection area. Refer to Section 5 for instructions on machine interfaces.
For more information on the fixing and interconnection arrangements, see Section 6. Peripheral trimming active device Trimming sensor pad Detection area Each peripheral trimming increases by 52mm (NZG 3010) Each joint trimming joint increases by 10mm Nominal pad size Each peripheral trimming (NZG 301 1) increases by 95mm 6 x 3/8 "tapping screw (not provided) 12 The dimension unit in Figure 8 is to use the fixing hole at the bottom of the cover 13 Polycarbonate housing 440F-C4000P steel housing 440F-C4 000S and 440F-C28013 DIN rail housing 440F-C4000D Section 5 - Installation Design This manual should be read completely before installation. It is recommended that the device be designed only by personnel with appropriate competence in electrical and mechanical engineering and experience in the design of safety related control systems. Many factors contribute to a safe and reliable installation. The following steps will ensure that nothing will be ignored and the installation can be planned and implemented with minimum trouble and maximum confidence. The details of the procedures followed are based on European best practices and comply with the EU Machinery Directive. Even if these requirements do not apply to your installation, we recommend that you follow the same steps, but modify the details to comply with relevant statutory requirements or codes of practice (such as ANSI, OSHA). 5.1 Nature of the hazard When the operator is near the hazard, the system can eliminate the hazard by isolating the power supply. Additional measures are required to deal with other hazards identified in the risk assessment (e.g. part spray, hot surfaces, etc.). These measures may include fixed guards, interlocked guards, warning notices, etc. If necessary, please contact the supplier for more information. Note: Risk assessment is included in EN 291-1 and detailed in EN 1050.5.2 Nature of safety protection. The system design must meet three main requirements: 1. If someone can enter the dangerous area, the machine must be stopped. 2. The machine must be stopped before approaching personnel can enter the dangerous area. 3. Do not bypass the system easily. It is recommended to use a mat system that can sense presence throughout the area that may enter the hazardous area. (See the example in Figure 9). It is not recommended to use the mat subsystem for other purposes, such as perimeter access control or machine activation. If you are considering using the mat subsystem for any application not covered in this manual, please contact the supplier. Fig