安装后,应将本手册保存在安全且可接近的地方。如需进一步帮助,请联系供应商。第1节-储存和搬运1.1储存控制装置和垫传感器应储存在-40°C至+70°C的温度范围内。垫子传感器应垂直存放。1.2搬运和运输控制装置和垫传感器应在-40°C至+70°C的温度范围内运输。应使用原始包装或类似包装,必要时应加固,以防止损坏和弯曲。始终小心打开包装,避免被刀具等损坏。当传感器垫移动到位时,切勿通过其连接线拉动或提起传感器。对于较大的传感器垫,需要两个人才能安全起吊并防止传感器垫因过度弯曲而损坏。4第2节-系统描述系统包括一个或多个互连的压敏垫和一个控制单元。检测区域内没有“死区”。单个传感器垫部分有矩形标准尺寸,也有特殊切割形状,最大尺寸为最大标准垫。
所有传感器垫具有相同的结构和操作原理。每个垫子都有两个导电板,它们由非导电的可压缩隔板隔开。这些垫子在24V DC下工作,并串联在一起,以形成机器周围危险区域的地面感应系统。通过垫的电路由控制单元监控,当区域空闲时,控制单元向机器控制电路提供信号。当踏上任何垫子时,导电板接触,电路中的电阻下降。这由关闭机器的控制单元监控。将检测到垫、接线或控制单元中的任何单个电气故障,并且控制单元输出将进入安全(OFF)状态。模制乙烯基传感器垫密封至IP 67.440F-C28013控制单元。该单元包括一个八通道传感垫系统。当踩下任何垫子时,控制单元将关闭机器,并在CHANNEL FAULT STATUS(信道故障状态)显示屏上显示正在操作的垫子。有两种操作模式:手动复位和自动复位。在手动复位模式下,输出“ON”信号只能在移除驱动力并复位后恢复。
After installation, keep this manual in a safe and accessible place. For further assistance, please contact the supplier. Section 1 - Storage and Handling 1.1 Storage controls and pad sensors shall be stored in a temperature range of - 40 ° C to+70 ° C. Cushion sensors should be stored vertically. 1.2 The handling and transportation control devices and pad sensors shall be transported within the temperature range of - 40 ° C to+70 ° C. The original packaging or similar packaging shall be used, and if necessary, it shall be reinforced to prevent damage and bending. Always open the package carefully to avoid being damaged by knives, etc. When the sensor pad moves in place, do not pull or lift the sensor through its connecting wire. For larger sensor pads, two people are required to lift safely and prevent damage to the sensor pads due to excessive bending. 4 Section 2 - System Description The system consists of one or more interconnected pressure sensitive pads and a control unit. There is no "dead zone" in the detection area. The single sensor pad has rectangular standard size and special cutting shape. The maximum size is the maximum standard pad.
All sensor pads have the same structure and operating principle. Each cushion has two conductive plates, which are separated by non-conductive compressible partitions. These pads work at 24V DC and are connected in series to form a ground sensing system in the hazardous area around the machine. The circuit through the pad is monitored by the control unit, which provides signals to the machine control circuit when the area is free. When stepping on any mat, the conductive plate contacts and the resistance in the circuit decreases. This is monitored by the control unit that shuts down the machine. Any single electrical fault in the pad, wiring or control unit will be detected, and the control unit output will enter the OFF state. Molded vinyl sensor gasket seals to IP 67.440F-C28013 control unit. The unit includes an eight channel sensing pad system. When any mat is depressed, the control unit shuts down the machine and displays the mat being operated on the CHANNEL FAULT STATUS display. There are two operation modes: manual reset and automatic reset. In the manual reset mode, the output "ON" signal can only be restored after the driving force is removed and reset.