MVME5100-0163处理器卡件
((WinVista/7/8)OPC服务器7-16 DriveWindow 2如果您从未(或很少)需要连接到ACS800系列驱动器,我们建议您建议DriveDA在文件DriveDA的[Servers]部分设置Count=1,以完全不连接到DriveOPC。ini:[Servers]并行=1计数=1[Servers.0]名称=ABB。DriveDA ParallelChannels=1[Servers.1]名称=ABB。SMP文件位于:•Documents and Settings\All Users\Application Data\DriveWare(WinXP)或•Program Data\DriveWare(WinVista/7/8)另请参阅:连接到OPC服务器7。配置DDCS/UDP DriveWindow 2.40(实际上包含DriveOPC 2.10)支持新的DDCS/UDP协议,该协议允许DDCS光纤网络通过以太网连接到PC。它需要支持该协议的设备,如NETA-21。OPC服务器DriveWindow 2 7-17 7.1.1启用NETA-21 DDCS网关NETA-21的出厂设置已禁用NETA-21中的DDCS网关。要能够使用DDCS/UDP,必须启用网关。为此,您可以使用web浏览器连接到NETA-21 IP地址。您需要知道用户名和密码才能登录。然后导航到设置->设备界面,选择DDCS选项卡并单击设置。将显示界面设置对话框。选择Enable from Ethernet GW,单击Save,最后注销。7.1.2配置DDCS/UDP DDCS/UDP配置信息保存在dwc_NETA中。ini文件,位于:•Documents and Settings\All Users\Application Data\DriveWare(WinXP)或•Program Data\DriveWare(WinVista/7/8)DDCS/UDP配置对话框实际上实现了一个特殊的ini文件编辑器。OPC服务器7-18 DriveWindow 2配置通过从网络菜单的配置子菜单中选择DDCS/UDP来完成。请注意,如果您连接到OPC服务器,DDCS/UDP命令将变灰。配置只能在OPC服务器断开时进行。将打开DDCS/UDP配置对话框,您可以选择要使用的配置。OPC服务器DriveWindow 2 7-19 7.1.3配置您可以有几种现成的配置(例如,针对不同的站点),但当您连接到DriveOPC时,只有一种配置在使用中。除了默认配置之外,您可以添加、重命名和删除自己的配置。可以编辑所有配置并将其复制到新配置。您可以从“编辑”菜单或右键单击“当前配置”下拉列表时显示的上下文菜单中选择操作。或注意,您也可以通过点击Del键来删除所选的当前配置。配置可以包含以下连接到DDCS/UDP设备的方法的任意组合:•固定IP列表(不在默认配置中)。•附近的设备,即本地以太网段中的所有设备(通过广播搜索)。•Intranet设备,即与PC位于同一子网中的所有设备(通过广播搜索)。•由IP地址和子网掩码标识的远程子网列表(不在默认配置中)。实际上,固定IP是具有子网掩码255.255.255.255的远程子网的一种特殊情况。但是,您可以为其指定固定的信道号,这在其他方法中是不可能的。在实践中,您只使用只有固定IP的配置。使用广播的方法可以用于具有DDCS/UDP设备的训练或其他条件,其IP地址频繁改变。OPC Server 7-20 DriveWindow 2 7.1.4测试配置要测试选定的当前配置,请单击测试按钮。如果按钮呈灰色,则表示您有旧版本的DriveOPC
WinVista/7/8) OPC Server 7-16 DriveWindow 2 If you never (or seldom) need to connect to an ACS800 family of drive, we recommend that you advice DriveDA not to connect to DriveOPC at all by setting Count=1 in the [Servers] section of the file DriveDA.ini: [Servers] Parallel=1 Count=1 [Servers.0] Name=ABB.DriveDA ParallelChannels=1 [Servers.1] Name=ABB.SMP The file is located in: • Documents and Settings\All Users\Application Data\DriveWare (WinXP), or • Program Data\DriveWare (WinVista/7/8) See Also: Connecting to OPC Server 7. Configuring DDCS/UDP DriveWindow 2.40 (actually DriveOPC 2.10 included in it) supports a new DDCS/UDP protocol, which allows the DDCS fibre optic network to be connected to the PC over Ethernet network. It requires a device supporting the protocol, such as NETA-21. OPC Server DriveWindow 2 7-17 7.1.1 Enabling NETA-21 DDCS Gateway Factory settings of NETA-21 have the DDCS gateway disabled in NETA-21. To be able to use DDCS/UDP, the gateway has to be enabled. To do that you use a web browser to connect to the NETA-21 IP address. You need to know a user name and password to get logged in. Then navigate to Settings -> Device interfaces, select DDCS tab and click Settings. Interface settings dialog box is displayed. Select Enable from Ethernet GW, click Save and finally log out. 7.1.2 Configuring DDCS/UDP DDCS/UDP configuration information is kept in dwc_NETA.ini file, which resides in: • Documents and Settings\All Users\Application Data\DriveWare (WinXP), or • Program Data\DriveWare (WinVista/7/8) The DDCS/UDP Configuration dialog boxes actually implement a special INI-file editor. OPC Server 7-18 DriveWindow 2 Configuring is done by selecting DDCS/UDP from the Configuration submenu of the Network menu. Note that the DDCS/UDP command is grayed if you are connected to an OPC Server. Configuring can only be done while OPC Server is disconneced. The DDCS/UDP Configuration dialog box is opened and you can choose the configuration to work with. OPC Server DriveWindow 2 7-19 7.1.3 Configurations You can have several readymade configurations (for different sites, for example), but only one of them is in use when you connect to DriveOPC. With the exception of the Default configuration, you can add, rename, and delete configurations of your own. All configurations can be edited and copied to a new. You can select to operation either from the Edit menu or the context menu, which is shown when you right click Current configuration drop down list. or Note that you can delete the selected Current configuration also by hitting the Del key. A configuration can contain any combination of the following methods of connecting to DDCS/UDP devices: • A list of fixed IPs (not in the Default configuration). • Devices near, i.e., all devices in the local Ethernet segment (searched by broadcast). • Intranet devices, i.e., all devices in the same subnet as the PC (searched by broadcast). • A list of remote subnets identified by an IP address and subnet mask (not in the Default configuration). Actually a fixed IP is a special case of remote subnet having the subnet mask 255.255.255.255. However, you can specify a fixed channel number for it, which is not possible in other methods. In practise you use only configurations that have just fixed IPs. The methods using broadcast could be used in training or other conditions having DDCS/UDP devices, IP addresses of which change frequently. OPC Server 7-20 DriveWindow 2 7.1.4 Testing a Configuration To test the selected Current configuration, click the Test button. If the button is grayed, you either have an old version of DriveOPC