PFCL 301E-0.5 DCS模块卡件
仅限HCSP编程器和上传/下载功能HAS1编程器/控制器,带模拟电位计HCS1编程仪/控制器,带有模拟电位计和上传/上传功能HAS2编程器/控制器,带数字电位计HCS2编程仪/控制器,IP65/54(NEMA类型4/12)仅限HJP编程器HJ2编程器/控制器,带数字电位计通信选项–-B框架及以上(适配器6)GM1单点远程I/O B框架GM2 RS-232/422/485,DF1和DH485 B框架GM5 DeviceNet™ GM6增强型DeviceNet™ 通信选项–-所有框架(适配器1)GMS1 GM1,带卡入式支架GMS2 GM2,带卡扣式支架GMS5 GM5,带卡合式支架GMS6 GM6,带卡进式支架控制接口选项L4 TTL触点L4E TTL触点和编码器反馈L7E TTL触点与编码器反馈。用于编码器损耗检测L5 24V AC/DC L5E 24V AC/DC和编码器反馈L8E 24V AC/直流和编码器反馈与编码器损耗检测L6 115V AC L6E 115V AC和编码器反馈L9E 115V交流和编码器反馈用于编码器损耗探测模拟接口选项–插槽A•选择不多于一个–可配置输入/输出为10V或20mA LA2两个隔离可配置输入LA6一个隔离双极输入(±10V或±20mA)和一个隔离热敏电阻输入LA7一个隔离两极输入(±10V或±20mA,非隔离输出(1-可配置,1-20mA)LA3两个隔离可配置输出LA4一个隔离可组态输入和输出LA5隔离脉冲输入、非隔离脉冲输出和单端、非隔离可组态输出共模扼流圈–-F&G框架(必须为F框架指定)CM内部共模扼流(工厂安装)NCM无共模扼流➀ 必须指定语言以确保装运适当的用户手册。➁ 封闭结构的G型机架标准驱动器通过配置驱动器程序提供,并且在HP额定值后有“A”后缀。➂ IP 65(NEMA类型4)和IP 54(NEMA类型12)配置的D到G机架驱动器通过配置驱动器程序提供。➃ “xPR”具有“roll=in”型机箱。电压和标称HP额定值组合代码额定值AQ BR CW A B BP/BPR BX C CP/CPR Q R RX W F05 0.37(0.5)● ● F07 0.56(0.75)● ● F10 0.75(1)●●● F15 1.2(–––1336 PLUS-6.16–2001年9月简介1-5驱动器额定值资格有几个因素会影响驱动器额定值。如果存在多个因素,则必须乘以降额百分比。例如,如果14安培驱动器安装在海拔2公里(6600英尺)处,且输入线电压高达2%,实际额定电流为:14 x 94%海拔降额x 96%高输入线路降额=12.6安培。用户提供的机柜1336 PLUS II驱动器安装在用户提供的
Only HCSP Programmer Only & Upload/Download Capability HAS1 Programmer/Controller w/Analog Pot HCS1 Programmer/Controller w/Analog Pot & Upload/Download Capability HAS2 Programmer/Controller w/Digital Pot HCS2 Programmer/Controller w/Digital Pot & Upload/Download Capability Human Interface Module, IP65/54 (NEMA Type 4/12) HJP Programmer Only HJ2 Programmer/Controller w/Digital Pot Communication Options –- B Frame & Up (Adapter 6) GM1 Single Point Remote I/O B Frame GM2 RS-232/422/485, DF1 & DH485 B Frame GM5 DeviceNet™ GM6 Enhanced DeviceNet™ Communication Options –- All Frames (Adapter 1) GMS1 GM1 with Snap-In Cradle GMS2 GM2 with Snap-In Cradle GMS5 GM5 with Snap-In Cradle GMS6 GM6 with Snap-In Cradle Control Interface Options L4 TTL Contact L4E TTL Contact & Encoder Feedback L7E TTL Contact & Encoder Fdbck. for use with Encoder Loss Detection L5 24V AC/DC L5E 24V AC/DC & Encoder Feedback L8E 24V AC/DC & Encoder Feedback for use with Encoder Loss Detection L6 115V AC L6E 115V AC & Encoder Feedback L9E 115V AC & Encoder Feedback for use with Encoder Loss Detection Analog Interface Options – Slot A • Choose No More than One – Configurable Inputs/Outputs are 10V or 20mA LA2 Two Isolated Configurable Inputs LA6 One Isolated Bi-polar Input (±10V or ±20mA) and One Isolated Thermistor Input LA7 One Isolated Bi-polar Input (±10V or ±20mA) and One Isolated Configurable Input Analog Interface Options – Slot B • Choose No More than One – Configurable Inputs/Outputs are 10V or 20mA LA1 Single-ended, Non-isolated Configurable (including Pot) Input & 2 Single-ended, Non-isolated Outputs (1 - Configurable, 1 - 20mA) LA3 Two Isolated Configurable Outputs LA4 One Isolated Configurable Input & Output LA5 Isolated Pulse Input, Non-isolated Pulse Output & Single-ended, Non-isolated Configurable Output Common Mode Choke –- F & G Frame (must be specified for F Frame) CM Internal Common Mode Choke (factory installed) NCM No Common Mode Choke ➀ Language must be specified to ensure shipment of appropriate User Manual. ➁ G Frame Standard Drives in enclosed construction are supplied through the Configured Drives Program and will have an "A" suffix after the HP rating. ➂ D through G Frame drives in IP 65 (NEMA Type 4) and IP 54 (NEMA Type 12) configurations are supplied through the Configured Drives Program. ➃ "xPR" has a "roll=in" type chassis. Voltage and Nominal HP Rating Combinations Code Rating AQ BR CW A B BP/ BPR BX C CP/ CPR Q R RX W F05 0.37 (0.5) ● ● F07 0.56 (0.75) ● ● F10 0.75 (1) ●●● F15 1.2 ( – – – 1336 PLUS-6.16 - September, 2001 Introduction 1-5 Drive Rating Qualifications Several factors can affect drive rating. If more than one factor exists, derating percentages must be multiplied. For example, if a 14-amp drive is installed at a 2km (6,600 ft.) altitude and has a 2% high-input line voltage, the actual amp rating is: 14 x 94% altitude derating x 96% high-input line derating = 12.6 amps. User Supplied Enclosures 1336 PLUS II drives installed in user supplied