PFTL101A 0.5 3BSE030638R3100输入输出模块
•需要一个适配器,用于EtherNet/IP链路上的分布式1756 I/O•与其他EtherNet/IP设备(消息和HMI)通信•桥接EtherNet/IP链路,以将消息路由到其他网络上的设备1769-L23E-QB1B或1769-L23E-QBFC1B控制器,带有集成的EtherNet/IP端口1769-L32E或1769-L35E控制器,带有整合的EtherNet/IP端口1768-ENBT桥接器所有CompactLogix 5370L1,L2和L3控制器•需要通过Internet浏览器远程访问本地控制器中的标签•支持自定义网页•桥接EtherNet/IP链接以将消息路由到其他网络上的设备(无I/O支持)--1768-EWEB web服务器—通过EtherNet 1769-L23E-QB1B或1769-L22E-QBFC1B控制器使用1769-I/O作为远程I/O,并集成EtherNet/IP端口和1769-AENTR1769-L32E或1769-L35E控制器,带有集成EtherNet/IP端口和1769-AENTR 1769-AENT R 1769-AENTR 6罗克韦尔自动化出版物1769-TD007D-EN-P-2014年5月CompactLogix通信模块规范表3-技术规范-1768和1769 EtherNet/IP模块属性1768-ENBT,1768-EWEB 1769-AENTR(1)EtherNet/IP通信速率10/100 Mbps 10/100 Mbps Logix通信连接128 128 TCP/IP通信连接64 96电流汲取5V DC N/A 500 mA电流汲取@5.2V DC 834 mA N/A电流汲取@24V DC 0 mA N/A功耗4.34 W N/A功率耗散4.38 W N/A隔离电压30V(连续),功能绝缘型,以太网至系统在710V DC下测试60秒50V(连续)基本绝缘类型在710V直流下测试60 s重量,约0.213 kg(7.5 oz)0.280 kg(0.61 lb)尺寸(高x宽x深),约132 x 56.7 x 105.1 mm(5.20 x 2.23 x 4.12 in.)118 x 50 x 87 mm(4.65 x 1.97 x 3.43 in.)。)插槽宽度1 1模块位置DIN导轨或面板安装DIN导轨或板安装安装螺钉扭矩1.16 Nm(10 lbin)-使用M4或#8螺钉1.16 Nm,使用M4或8号螺钉端口1以太网RJ45 5类2以太网RJ45 5级电线尺寸以太网连接:符合IEC 60603-7的RJ45连接器,符合TIA 568-B的2或4对5e类最小电缆。1或符合ISO/IEC 24702的5类电缆。导线类别2-通信端口上(2)1-通信端口(1)北美温度代码T4A T3C外壳类型额定值无(开放式)无(开放型)(1)1769-AENTR适配器必须与以下罗克韦尔自动化电源型号之一一起使用:1769-PA2、1769-PB2、1769PA4、,或1769-PB4。(2)按照系统级安装手册中的描述,使用此导线类别信息规划导线布线。参见工业自动化布线和接地指南,出版物1770-4.1。表4-认证-1768和1769 EtherNet/IP模块认证(1)1768-ENBT、1768-EWEB 1769-AENTR c-UL-us UL认证工业控制设备,适用于美国和加拿大。参见UL文件E65584。UL列出的I级2类A、B、C、D组危险场所,已在美国和加拿大认证。参见UL文件E194810。UL列出的工业控制设备,经美国和加拿大认证。参见UL文件E322657。UL列出了I级2类A、B、C、D组危险场所,已在美国和加拿大认证。参见UL文件E334470.CE欧盟2004/108/IEC EMC指令,符合:EN 61326-1;测量/控制/实验室。,工业要求EN 61000-6-2;工业抗扰度EN 61000-6-4;工业排放EN 61131-2;可编程控制器(第8条,A区和B区)欧盟2004/108/EC EMC指令,符合:EN 61326-1;测量/控制/实验室。
• Requires an adapter for distributed 1756 I/O on EtherNet/IP links • Communicates with other EtherNet/IP devices (messages and HMI) • Bridges EtherNet/IP links to route messages to devices on other networks 1769-L23E-QB1B or 1769- L23E-QBFC1B controller with integrated EtherNet/IP port 1769-L32E or 1769-L35E controller with integrated EtherNet/IP port 1768-ENBT bridge All CompactLogix 5370 L1, L2 and L3 controllers • Requires remote access via an Internet browser to tags in a local controller • Support custom web pages • Bridges EtherNet/IP links to route messages to devices on other networks (no I/O support) — — 1768-EWEB web server — Uses 1769-I/O as remote I/O via EtherNet 1769-L23E-QB1B or 1769- L23E-QBFC1B controller with integrated EtherNet/IP port and 1769-AENTR 1769-L32E or 1769-L35E controller with integrated EtherNet/IP port and 1769- AENTR 1769-AENTR 1769-AENTR 6 Rockwell Automation Publication 1769-TD007D-EN-P - May 2014 CompactLogix Communication Modules Specifications Table 3 - Technical Specifications - 1768 and 1769 EtherNet/IP Modules Attribute 1768-ENBT, 1768-EWEB 1769-AENTR(1) EtherNet/IP communication rate 10/100 Mbps 10/100 Mbps Logix communication connections 128 128 TCP/IP communication connections 64 96 Current draw 5V DC N/A 500 mA Current draw @ 5.2V DC 834 mA N/A Current draw @ 24V DC 0 mA N/A Power consumption 4.34 W N/A Power dissipation 4.38 W N/A Isolation voltage 30V (continuous), functional insulation type, Ethernet to system Tested at 710V DC for 60 s 50V (continuous) basic insulation type Tested at 710V DC for 60 s Weight, approx. 0.213 kg (7.5 oz) 0.280 kg (0.61 lb) Dimensions (HxWxD), approx. 132 x 56.7 x 105.1 mm (5.20 x 2.23 x 4.12 in.) 118 x 50 x 87 mm (4.65 x 1.97 x 3.43 in.) Slot width 1 1 Module location DIN rail or panel mount DIN rail or panel mount Mounting screw torque 1.16 Nm (10 lbin) - use M4 or #8 screws 1.16 Nm (10 lbin) - use M4 or #8 screws Ports 1 Ethernet RJ45 Category 5 2 Ethernet RJ45 Category 5 Wire size Ethernet connections: RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702. Wire category 2 - on communication ports(2) 1 - on communication ports(1) North American temperature code T4A T3C Enclosure type rating None (open-style) None (open-style) (1) The 1769-AENTR adapter must be used with one of the following Rockwell Automation power supply models: 1769-PA2, 1769-PB2, 1769-PA4, or 1769-PB4. (2) Use this conductor category information for planning conductor routing as described in the system-level installation manual. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Table 4 - Certifications - 1768 and 1769 EtherNet/IP Modules Certification(1) 1768-ENBT, 1768-EWEB 1769-AENTR c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E322657. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E334470. CE European Union 2004/108/IEC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab.