PFTL101A 0.5KN 3BSE004160R1系统模块卡件
61000-4-2:6 kV接触放电8 kV空气放电辐射射频抗扰度IEC 61000-4-3:10V/m,1 kHz正弦波80%AM,从80…2000 MHz 10V/m,200 Hz 50%脉冲100%AM,从900 MHz 10V/m到200 Hz 50%,从1890 MHz 10V/m和1 kHz正弦波80%AM,从2000…2700 MHz EFT/B,抗扰度IEC61000-4-4:±2kV,通信端口浪涌瞬态抗扰度61000-4-5:通信端口上的±2 kV线路接地(CM)IEC 61000-4-5:通信端口上±1 kV线路接地线(CM)传导射频抗扰度IEC 61000-4-6:10V rms,1 kHz正弦波80%AM,150 kHz…80 MHz 4罗克韦尔自动化出版物1769-TD007D-EN-P-2014年5月CompactLogix通信模块规范表2-环境规范-1769通信模块属性1769-AENTR 1769-SDN,1769-ADN温度,运行IEC 60068-2-1(测试Ad,运行低温),IEC 60068-2-2(测试Bd,运行干热),IEC 6008-2-14(测试Nb,运行热冲击)0…60°C(32…140°F)温度,周围空气,最高60°C,IEC 60068-2-2(测试Bb,未包装的非操作性干热)、IEC 60068-2-14(测试Na,未包装非操作性热冲击)-40…85°C(-40…185°F)相对湿度IEC 60068-2-30(测试Db,非操作性湿热)5…95%非冷凝振动IEC 60068-2-6(测试Fc,操作)2 g@10…500 Hz冲击,操作IEC 60068-2-27(测试Ea,未包装冲击)15 g 30 g冲击,非工作IEC 60068-2-27(试验Ea,无包装冲击)30 g 50 g排放CISPR 11(IEC 61000-6-4):A类CISPR 11,A级ESD抗扰度IEC 61000-4-2:6 kV接触放电8 kV空气放电辐射射频抗扰度IEC61000-4-3:10V/m,1 kHz正弦波80%AM,从80…2000 MHz 10V/m,200 Hz 50%脉冲100%AM,从900 MHz 10V/m和200 Hz 50%脉冲100%AM,1890 MHz 10V/m200 Hz 50%脉冲100%AM,900 MHz 1V/m,1 kHz正弦波80%AM,来自2000…2700 MHz EFT/B抗扰度IEC 61000-4-4:通信端口5 kHz时±3 kV IEC 61000-4-4:通信端口5 Hz时±2 kV浪涌瞬态抗扰度IEC61000-4-5:通信端口±2 kV线路接地(CM61000-4-6:10V rms,1 kHz正弦波80%AM,150 kHz…80 MHz罗克韦尔自动化出版物1769-TD007D-EN-P-2014年5月5 CompactLogix通信模块规范通信连接ControlLogix系统使用连接在设备之间建立通信链路。连接类型包括:•控制器到本地I/O模块或本地通信模块。•控制器至远程I/O或远程通信模块。•控制器到远程I/O(机架优化)模块。•生产和消费的标签信息。•通过RSLogix 5000编程软件访问控制器。•RSLinx软件对HMI或其他应用程序的控制器访问。通过将控制器配置为与系统中的其他设备通信,可以间接确定控制器使用的连接数。连接的限制最终可能存在于用于连接的通信模块中。如果消息路径路由通过通信模块,则与消息相关的连接也计入该通信模块的连接限制。以太网/IP网络以太网工业网络协议(EtherNet/IP)是一种开放的工业网络标准,支持实时I/O消息传递和消息交换。EtherNet/IP网络使用现成的以太网通信芯片和物理介质。有关控制器规格,请参阅CompactLogix控制器规格,出版物1769-TD005。如果您的应用程序选择1769-L23x控制器选择1769-L3x控制器选择1769L4x、1769-L4xS控制器选择CompactLogix5370控制器•控制标准和安全I/O模块和驱动器
61000-4-2: 6 kV contact discharges 8 kV air discharges Radiated RF Immunity IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz EFT/B Immunity IEC 61000-4-4: ±2kV at 5 kHz on communications ports Surge Transient Immunity IEC 61000-4-5: ±2 kV line-earth(CM) on communications ports IEC 61000-4-5: ±1 kV line-earth(CM) on communications ports Conducted RF Immunity IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz 4 Rockwell Automation Publication 1769-TD007D-EN-P - May 2014 CompactLogix Communication Modules Specifications Table 2 - Environmental Specifications - 1769 Communication Modules Attribute 1769-AENTR 1769-SDN, 1769-ADN Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) 0…60 °C (32…140 °F) Temperature, surrounding air, max. 60 °C (140 °F) Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) -40…85 °C (-40…185 °F) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Nonoperating Damp Heat) 5…95% noncondensing Vibration IEC 60068-2-6 (Test Fc, Operating) 2 g @ 10…500 Hz Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock) 15 g 30 g Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock) 30 g 50 g Emissions CISPR 11 (IEC 61000-6-4): Class A CISPR 11 (IEC 61000-6-4): Group 1, Class A ESD Immunity IEC 61000-4-2: 6 kV contact discharges 8 kV air discharges Radiated RF Immunity IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 30…2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 1V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz EFT/B Immunity IEC 61000-4-4: ±3 kV at 5 kHz on communications ports IEC 61000-4-4: ±2 kV at 5 kHz on communications ports Surge Transient Immunity IEC 61000-4-5: ±2 kV line-earth(CM) on communications ports Conducted RF Immunity IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz Rockwell Automation Publication 1769-TD007D-EN-P - May 2014 5 CompactLogix Communication Modules Specifications Communication Connections A ControlLogix system uses connections to establish communication links between devices. The types of connections include: • controller-to-local I/O modules or local communication modules. • controller-to-remote I/O or remote communication modules. • controller-to-remote I/O (rack-optimized) modules. • produced and consumed tags. • messages. • controller access by RSLogix 5000 programming software. • controller access by RSLinx software for HMI or other applications. You indirectly determine the number of connections the controller uses by configuring the controller to communicate with other devices in the system. The limit of connections may ultimately reside in the communication module you use for the connection. If a message path routes through a communication module, the connection related to the message also counts towards the connection limit of that communication module. EtherNet/IP Network The Ethernet Industrial network protocol (EtherNet/IP) is an open industrial-networking standard that supports both real-time I/O messaging and message exchange. The EtherNet/IP network uses off-the-shelf Ethernet communication chips and physical media. For controller specifications, see CompactLogix Controllers Specifications, publication 1769-TD005. If your application Select for a 1769-L23x controller Select for a 1769-L3x controller Select for a 1769-L4x, 1769-L4xS controller Select for a CompactLogix 5370 controller • Controls standard and safety I/O modules and drives