PFTL-101A 3BSE008508R1工控机器人备件
引脚1:T1(黑色)引脚2:T2(白色)引脚3:T3(红色)引脚4:接地(绿色/黄色)引脚1:T1)引脚2:接地电机连接器的保护(M22)插座连接-(M21)公告280E/281E:3 Hp或更低公告284E:电机连接器的5 Hp或更少插座连接-10 Hp或更高(M35)-公告280E/281 E仅用于输入三相电源的插座连接-25 A短路保护(M35插座引脚输出引脚1:Tx+引脚2:Rx+引脚3:Tx引脚4:RxPin 1:+24V(A3或DNET)引脚2:输入0引脚3:公共引脚4:输入1引脚5:NC(无连接)引脚1:NC(无接头)引脚2:NC(无接线)引脚3:公共针4:输出+24V DC(A1)引脚5:NC)引脚1:GND(绿色/黄色)引脚2:BR+(黑色)引脚3:BR-(白色)引脚1:+24V DC无开关(A3)(红色)引脚2:公共(A2)(黑色)引脚3:PE(绿色)引脚4:未使用(空白)引脚5:+24V DC开关(A1)(蓝色)引脚6:未使用(白色)规格动态制动器(M22)的插座连接-公告284E仅用于输入控制电源的插座连接-24V DC仅用于输入的插座连接(M12)用于输出的插座连接,EtherNet/IP版本(M12)插座连接EtherNet/IP(M12)公告280E/281E ArmorStart®分布式电机控制器出版物280E-SG001B-EN-P 9电气额定值UL/NEMA IEC电源电路额定工作电压200…480V 200…480V额定绝缘电压600V 600V额定脉冲电压6kV 6 kV介质耐受2200V AC 2500V AC工作频率50/60 Hz 50/60 Hz使用类别N/A AC-3防震保护N/A IP2X额定工作电流最大280_-_-10A-*1.2 A 280_-__ 10B-*2.5 A 280_/__ 10C-*5.5 A 280_-__-10D-*16 A控制电路额定工作电压24V DC(+10%,-15%)A2(应在电压源接地)额定绝缘电压250V 250V额定脉冲电压-4 kV电介质耐受1500V AC 2000V交流过电压III类工作频率50/60 Hz短路保护SCPD性能类型1额定电流电压480Y/277V 480/480V 600Y/347V 600V 0.24…1.2 A Sym。安培RMS 0.5…2.5 A 65 kA 65 kA 30 kA 30 kA 1.1…5.5 A 3.2…16 A 30 kA 30 kA 30 kA 30 kV SCPD列表尺寸根据NEC集团电机-连接2个输出(Micro/M12)4个输入(Micro/M2)接地端子电机连接LED状态指示本地断开IP地址开关嵌入式2端口开关公告280E/281E ArmorStart with EtherNet/IP通信公告280E/281 E ArmorStart®分布式电机控制器10出版物280E-SG001B-EN-P规范UL/NEMA IEC环境工作温度范围-20…+40°C(-4…+104°F)存储和运输温度范围-25+85°C(-13…+185°F)海拔2000 m湿度5…95%(非冷凝)污染等级3外壳等级NEMA 4/12/13 IP67近似装运重量18.1 kg(40 lb)机械抗冲击运行15 G非运行30 G抗振动运行1 G,0.15 mm(0.006 in.)位移非运行2.5 G,0.38 mm(0.015 in.)。)位移电源和接地端子电线尺寸一次/二次端子:(#16…#10 AWG)一次/次端子:1.5…4.0 mm2拧紧力矩一次端子:10.8 lb•in二次端子,4.5 lb•in一次端子,(1.2 N•m)二次端子。(9 mm)控制和安全监视器输入导线尺寸#18…#10 AWG 1.0…4.0 mm2拧紧力矩6.2 lb•in 0.7 N•m导线带长度0.35 in。
Pin 1: T1 (black) Pin 2: T2 (white) Pin 3: T3 (red) Pin 4: Ground (green/yellow) Pin 1: T1 (black) Pin 2: Ground (green/yellow) Pin 3: T3 (red) Pin 4: T2 (white) Pin 1: L1 (black) Pin 2: L2 (white) Pin 3: L3 (red) Pin 4: Ground (green/yellow) Pin 1: L1 (black) Pin 2: Ground (green/yellow) Pin 3: L3 (red) Pin 4: L2 (white) Receptacle Connections for Incoming 3-phase Power - 10 A Short Circuit Protection (M22) Receptacle Connections for Motor Connector -(M22) Bulletin 280E/281E: 3 Hp or less Bulletin 284E: 5 Hp or less Receptacle Connections for Motor Connector - 10 Hp or greater (M35) — Bulletin 280E/281E only Receptacle Connections for Incoming 3-phase Power - 25 A Short Circuit Protection (M35) Receptacle Connections for Source or Control Brake — Bulletin 284E only ArmorStart Receptacle Pin Outs Pin 1: Tx+ Pin 2: Rx+ Pin 3: TxPin 4: RxPin 1: +24V (A3 or DNET) Pin 2: Input 0 Pin 3: Common Pin 4: Input 1 Pin 5: NC (no connection) Pin 1: NC (no connection) Pin 2: NC (no connection) Pin 3: Common Pin 4: Output +24V DC (A1) Pin 5: NC (no connection) Pin 1: GND (green/yellow) Pin 2: BR+ (black) Pin 3: BR- (white) Pin 1: +24V DC unswitched (A3)(red) Pin 2: Common (A2)(black) Pin 3: PE (green) Pin 4: Not used (blank) Pin 5: +24V DC switched (A1)(blue) Pin 6: Not used (white) Specifications Receptacle Connections for Dynamic Brake (M22) — Bulletin 284E only Receptacle Connections for Incoming Control Power - 24V DC Only Receptacle Connections for Input (M12) Receptacle Connections for Output, EtherNet/IP Version (M12) Receptacle Connections for EtherNet/IP (M12) Bulletin 280E/281E ArmorStart® Distributed Motor Controller Publication 280E-SG001B-EN-P 9 Specifications Electrical Ratings UL/NEMA IEC Power Circuit Rated Operation Voltage 200…480V 200…480V Rate Insulation Voltage 600V 600V Rated Impulsed Voltage 6 kV 6 kV Dielectric Withstand 2200V AC 2500V AC Operating Frequency 50/60 Hz 50/60 Hz Utilization Category N/A AC-3 Protection Against Shock N/A IP2X Rated Operating Current Max. 280_-___-10A-* 1.2 A 280_-___-10B-* 2.5 A 280_-___-10C-* 5.5 A 280_-___-10D-* 16 A Control Circuit Rated Operation Voltage 24V DC (+10%, -15%) A2 (should be grounded at voltage source) Rate Insulation Voltage 250V 250V Rated Impulsed Voltage — 4 kV Dielectric Withstand 1500V AC 2000V AC Overvoltage Category — III Operating Frequency 50/60 Hz Short Circuit Protection SCPD Performance Type 1 Current Rating Voltage 480Y/277V 480/480V 600Y/347V 600V 0.24…1.2 A Sym. Amps RMS 0.5…2.5 A 65 kA 65 kA 30 kA 30 kA 1.1…5.5 A 3.2…16 A 30 kA 30 kA 30 kA 30 kA SCPD List Size per NEC Group Motor — Connections 2 Outputs (Micro/M12) 4 Inputs (Micro/M12) Ground Terminal Motor Connection LED Status Indication Local Disconnect IP Address Switches Embedded 2-Port Switch Bulletin 280E/281E ArmorStart with EtherNet/IP Communications Bulletin 280E/281E ArmorStart® Distributed Motor Controller 10 Publication 280E-SG001B-EN-P Specifications UL/NEMA IEC Environmental Operating Temperature Range -20…+40 °C (-4…+104 °F) Storage and Transportation Temperature Range –25….+85 °C (–13…+185 °F) Altitude 2000 m Humidity 5…95% (non-condensing) Pollution Degree 3 Enclosure Ratings NEMA 4/12/13 IP67 Approximate Shipping Weight 18.1 kg (40 lb) Mechanical Resistance to Shock Operational 15 G Non-Operational 30 G Resistance to Vibration Operational 1 G, 0.15 mm (0.006 in.) displacement Non-Operational 2.5 G, 0.38 mm (0.015 in.) displacement Power and Ground Terminals Wire Size Primary/Secondary terminal: (#16 …#10 AWG) Primary/Secondary terminal: 1.5…4.0 mm2 Tightening Torque Primary terminal: 10.8 lb•in Secondary terminal: 4.5 lb•in Primary Terminal: (1.2 N•m) Secondary terminal: (0.5 N•m) Wire Strip Length 0.35 in. (9 mm) Control and Safety Monitor Inputs Wire Size #18…#10 AWG 1.0…4.0 mm2 Tightening Torque 6.2 lb•in 0.7 N•m Wire Strip Length 0.35 in.