PFTL101B 20KN 3BSE004203R1工控模块卡件
拐角周边装饰件(与440F-T3510、440F-T3310和440F-T3210一起使用)应力释放夹具挠性导管切割槽在此处使用锐边上的边缘槽剥开8mm的电线并插入压接筒。使用压接工具上正确的空腔尺寸压接。使用带导流板的加热枪加热压接接头,直到管道收缩,粘合剂收缩并流动。27 440F-T3210、440F-T3310和440F-T3510 440F-T3211和440F-T3411对于外部拐角装饰件,使用440F-T3014。对于内部拐角装饰件使用440F-T3105,440F-T3310和440F-T3510使用带挠性导管的应力消除夹具MAT 1 MAT 2 MAT 1 MAT 2 MAT3 MAT 1 MAT 2 45°45°MAT 3 MAT 4将所有装饰件切割成45°,如图所示。标记地板上的边缘装饰件固定位置,使装饰件与垫重叠。以装饰件上的孔为导向,标记并钻孔地板(如果需要,安装塞子)。清洁地板,并使用沉头螺钉将垫子和边缘装饰件固定到位,以适应应用。安装周边装饰件时,确保装饰件和地板之间或顶部和底部之间(取决于装饰件类型)没有任何电线被夹住或压碎。如果电线可能被夹住或拉动,应在电线离开周边装饰的地方使用应变消除夹。所有电线应采用适当的导管进行保护。如果可能,电线/导管不应穿过可能会绊倒的地板区域。如果无法避免这种情况,应将电线/导管封装在我们的《保护电线指南》440F-T3230中(参见第37页的可用备件)。6.2控制单元的安装和布线(也可参考第4节图7、第5.3.7节和第5.7节)控制单元应按照供应进行安装。除本手册所述的程序或连接外,不得对其进行修改或进行任何其他程序或连接。通过小心敲击(440F-C4000P)或钻出(440F-C4 000S,440FC28013)要使用的电缆入口位置来准备控制单元。输入电源必须单独布线,并通过与输出接线所用电源的单独入口进入控制单元。
corner perimeter trim (Use with 440F-T3510, 440F-T3310 & 440F-T3210) STRAIN RELIEF CLAMP FLEXIBLE CONDUIT CUT SLOTS HERE USE EDGE GROMMETS OVER SHARP EDGES Strip wires 8mm and insert into crimp barrel. Crimp using the correct cavity size on the crimp tool. Heat crimped splice, using heat gun with deflector, until tubing shrinks and adhesive shrinks and flows. 27 440F-T3210, 440F-T3310 & 440F-T3510 440F-T3211 & 440F-T3411 For external corner trim use 440F-T3014. For internal corner trim use 440F-T3015. 440F-T3210, 440F-T3310 & 440F-T3510 Use strain relief clamp with flexible conduit MAT 1 MAT 2 MAT 1 MAT 2 MAT 3 MAT 1 MAT 2 45° 45° MAT 3 MAT 4 MITRE ALL TRIMS TO 45° AS SHOWN IN MAT LAYOUTS Mark out the edge trim fixing positions on the floor allowing the trim to overlap the mat. Using the holes in the trim as a guide, mark out and drill the floor (fit plugs if required). Clean off the floor and fix the mats and edge trim in place using countersunk screws to suit the application. As the perimeter trim is fitted ensure none of the wiring is trapped or crushed between the trim and the floor or the top and bottom sections (depending on trim type). If there is a possibility that the wires may be caught or pulled, a strain relief clamp should be used where the wiring exits the perimeter trim. All wiring should be protected in suitable conduit. If possible, the wiring/conduit should not cross a floor area where it will be a tripping hazard. If it is not possible to avoid this, the wiring/conduit should be enclosed within our Protective Wire Guide 440F-T3230 (see Available Spares on page 37). 6.2 CONTROL UNIT INSTALLATION AND WIRING (also refer to section 4 fig. 7, section 5.3.7 and section 5.7) The control unit should be installed as supplied. It must not be modified or subjected to any procedures or connections other than those described in this manual. Prepare the control unit by carefully knocking out (440F-C4000P) or drill out (440F-C4000S, 440FC28013) the cable entry positions to be used. The input power supply must be separately routed and enter the control unit via a separate entry to those used for the output wiring.