PI3381 TRICONEX控制系统
壁挂式并联接线柜(两个断路器MBP)1,3 124100026-001 208/208 48.0 x 20.0 x 5.8 150远程监视器显示面板2 103002687-001 N/A N/A远程EPO开关(壁挂式)103002939 N/A N/A N/A 4区抗震套件103004896 N/A N/A N/A备件套件106711170 N/A N/B 20至30 kVA升级103004901 N/A N/A/A N/A升级为并联UPS模块UP08N-PAR N/A N/A.N/A三断路器维护旁路面板225A总线,200A中性和125A MBP、110A MIB,110A MIS)3 124100028-001 208/208 48.0 x 20.0 x 5.8 120带整体式120 KA TVSS(100A总线、200A中性线和60A MBP、MIB、MIS)3 125100028-002 208/208 60.0 x 20.0×5.8 120带36极配电装置(仅Cutler Hammer GHB 65 kAIC或GBHW 22 kAIC和BAB 10 kAIC)3 1241000-28-003 208/208 72.0 x 20.0x 5.8 210带36极分配装置和集成TVSS(仅限CutlerHammer GHB 65 kAIC、GBHW 22 kAIC和BAB 10 kAIC)3 124100028-004 208/208 90.0 x 20.0 x 5.8 225 1.400A总线、200A中性线、(1)350A MBP和(4)110A MIS。2.需要工业继电器和显示卡。请参阅X插槽连接选项表。3.面板的装运重量增加40磅,配备面板的面板增加50磅。零件号描述的X插槽连接选项值1 CTO数字8(如果单独订购)无(没有预装的X插槽卡)0–ConnectUPS-X Web/SNMP/xHub卡3 116750221-001调制解调器卡7 05146288-5501 Modbus卡4 103005425-5591中继卡(AS/400兼容)5 1018460工业继电器和显示卡2 6 103003055 CAN桥并行卡N/A 103004336 1。UPS有两个X插槽。一个卡可以在工厂安装,而第二个X插槽卡可以单独购买。2.5A@250V。提供(4)个C型继电器触点,用于将UPS报警集成到安全和报警系统中。还为远程监视器显示面板(零件号103002687-001)提供信号信息。9355零件号输入电缆插座1插座2计量Y03100011100000硬接线输入L21-20(2)L21-20,(2)本地功率计Y03100022100000硬接线输出L21-30,(3)L21-30输入L21-20(2)5-20(6)本地功率计Y031000FF100000硬接线输入L15-30(1)L15-30。com/powerquality 1.800.356.5794 15选件机柜壁挂式维护旁路面板美国8609 Six Forks Road Raleigh,NC 27615 U.S.A.免费电话:1.800.365.5794 www.eaton。com/powerquality加拿大安大略省:416.798.0112拉丁美洲巴西:55.11.3616.8500加勒比地区:1.949.452.9610墨西哥和中美洲:52.55.9000.5252南锥体:54.11.44343.6323欧洲/中东/非洲丹麦:45.3686.7910芬兰:358.94.52.661法国:33.1.6012.7400德国:49.0.7841.604.0意大利:39.02.66.04.05.40挪威:47.23.036.65.50葡萄牙:55.113616.8500瑞典:46.8.598.940.00英国:44.1753.608.700亚太地区澳大利亚/新西兰:61.2.9693.9366中国:86.21.6361.5599香港/韩国/台湾:852.2745.6682印度:91.11.4223.2300新加坡/东南亚:65.6829.8888伊顿,PowerChain Management是一个商品名
Wall-mount parallel tie cabinet (two-breaker MBP)1, 3 124100026-001 208/208 48.0 x 20.0 x 5.8 150 Remote monitor display panel2 103002687-001 N/A N/A N/A Remote EPO switch (wall mounted) 103002939 N/A N/A N/A Zone 4 seismic kit 103004896 N/A N/A N/A Spare parts kit 106711170 N/A N/A N/A 20 to 30 kVA upgrade 103004901 N/A N/A N/A Upgrade to a parallel UPS module UP08N-PAR N/A N/A N/A Three-breaker maintenance bypass panels 225A Bus, 200A Neutral and 125A MBP, 110A MIB, 110A MIS)3 124100028-001 208/208 48.0 x 20.0 x 5.8 120 With integral 120 KA TVSS (100A Bus, 200A Neutral and 60A MBP, MIB, MIS)3 124100028-002 208/208 60.0 x 20.0 x 5.8 120 With 36-pole distribution provisions (Cutler-Hammer GHB 65 kAIC, or GBHW 22 kAIC and BAB 10 kAIC only)3 124100028-003 208/208 72.0 x 20.0 x 5.8 210 With 36-pole distribution provisions and integrated TVSS (CutlerHammer GHB 65 kAIC, GBHW 22 kAIC and BAB 10 kAIC only)3 124100028-004 208/208 90.0 x 20.0 x 5.8 225 1. 400A Bus, 200A Neutral, (1) 350A MBP and (4) 110A MIS. 2. Requires Industrial Relay and Display Card. See X-Slot Connectivity Options table. 3. Add 40 lb. for shipping weight of panels and 50 lb. for panels with panelboard provisions. X-Slot Connectivity Options Value for Part Number Description1 CTO Digit 8 (if ordered separately) None (No Pre-installed X-Slot card) 0 – ConnectUPS-X Web/SNMP/xHub Card 3 116750221-001 Modem Card 7 05146288-5501 Modbus Card 4 103005425-5591 Relay Card (AS/400 compatible) 5 1018460 Industrial Relay and Display Card2 6 103003055 CAN Bridge Parallel Card N/A 103004336 1. The UPS has two X-Slots. One card can be factory installed while the second X-Slot card can be purchased separately. 2. 5A @ 250V. Provides (4) form-C relay contacts for integrating UPS alarms into security and alarm systems. Also provides signal information for the Remote Monitor Display Panel (part number 103002687-001). RPM Configurations for 9355 Part Number Input Cable Receptacle 1 Receptacle 2 Metering Y03100011100000 Hardwired Input L21-20 (2) L21-20 (2) Local Power Meter Y03100022100000 Hardwired Input L21-30 (2) L21-30 (2) Local Power Meter Y03100055100000 Hardwired Input L6-30 (3) L6-30 (3) Local Power Meter Y03100047100000 Hardwired Input L6-20 (3) 5-20 (6) Local Power Meter Y03100017100000 Hardwired Input L21-20 (2) 5-20 (6) Local Power Meter Y031000FF100000 Hardwired Input L15-30 (2) L15-30 (2) Local Power Meter Y301000BB100000 Hardwired Input IEC320-C19 (6) IEC320-C19 (6) Local Power Meter www.eaton.com/powerquality 1.800.356.5794 15 Options cabinet Wall-mount maintenance bypass panel UNITED STATES 8609 Six Forks Road Raleigh, NC 27615 U.S.A. Toll Free: 1.800.356.5794 www.eaton.com/powerquality Canada Ontario: 416.798.0112 LATIN AMERICA Brazil: 55.11.3616.8500 Caribbean: 1.949.452.9610 México & Central America: 52.55.9000.5252 South Cone: 54.11.4343.6323 Europe/Middle East/Africa Denmark: 45.3686.7910 Finland: 358.94.52.661 France: 33.1.6012.7400 Germany: 49.0.7841.604.0 Italy: 39.02.66.04.05.40 Norway: 47.23.03.65.50 Portugal: 55.11.3616.8500 Sweden: 46.8.598.940.00 United Kingdom: 44.1753.608.700 Asia Pacific Australia/NZ: 61.2.9693.9366 China: 86.21.6361.5599 HK/Korea/Taiwan: 852.2745.6682 India: 91.11.4223.2300 Singapore/SEA: 65.6829.8888 Eaton, PowerChain Management is a trade name