相应的充电率,可为电池正确充电并大大延长电池寿命•集成电池管理系统可测试和监测电池的健康状况和剩余寿命,并向用户提供通知,以指导预防性维护。伊顿的UPS电池可现场更换。一个人单独工作,可以轻松更换电池,而不会中断数据中心操作或受保护设备的电源。绿色功率性能9355提供了低输入电流失真和高功率因数的强大组合,以实现最大效率。9355在所有负载范围内以90%以上的效率运行,有助于降低公用事业成本,延长电池运行时间,并产生更冷的运行条件。此外,与具有竞争力的UPS产品相比,伊顿采用可持续材料和高效制造技术,大大减少了碳足迹。4伊顿公司10 kVA 15 kVA 20 kVA 30 kVA www.EATON.com/powerquality1.800.5356.5794 5行业领先的可扩展性和冗余当今的关键应用需要冗余以实现终极可靠性,而9355提供了。伊顿创新的热同步技术和可选的维护旁路并联连接柜与9355一起工作,提供了先进、经济高效的UPS并联系统。获得专利的热同步技术实现了系统负载共享,允许系统中的任何UPS模块作为任何其他模块的备份。热同步的无线并联功能还可确保在发生通信故障时的系统稳定性。使用壁挂式维护旁路并联连接柜,数据中心管理人员可以轻松地并联多达四个9355 UPS,以实现冗余或容量。UPS可以快速添加到预先安装的并联连接柜中,并在几分钟内联机,单个UPS可以被隔离和更换以进行维护,从而显著降低安装和维护费用。
啊harge rate accordingly, which properly charges the battery and greatly extends battery life • An integrated battery management system tests and monitors battery health and remaining lifetime, providing user notification to guide preventive maintenance Eaton's UPS batteries are field replaceable. One person, working alone, can easily replace a battery without disrupting data center operations or power to protected equipment. Green power performance The 9355 delivers a robust combination of low input current distortion and high power factor for maximum efficiency. Operating at greater than 90 percent efficiency across all load ranges, the 9355 helps to reduce utility costs, extend battery runtimes and produce cooler operating conditions. In addition, Eaton’s use of sustainable materials and highly efficient manufacturing technology results in dramatic savings in carbon footprint as compared to competitive UPS products. 4 EATON CORPORATION 10 kVA 15 kVA 20 kVA 30 kVA www.eaton.com/powerquality 1.800.356.5794 5 Industry-leading scalability and redundancy Today’s critical applications require redundancy for ultimate reliability—and the 9355 delivers. Eaton’s innovative Hot Sync technology and optional maintenance bypass parallel tie cabinet work together with the 9355 to provide an advanced, cost-effective UPS paralleling system. The patented Hot Sync technology enables system load sharing, allowing any UPS module in the system to serve as a backup for any other module. Hot Sync’s wireless paralleling capability also ensures system stability in the event of a communications failure. Using a wall-mounted maintenance bypass parallel tie cabinet, data center managers can easily parallel up to four 9355 UPSs for either redundancy or capacity. UPSs can be quickly added to the pre-installed parallel tie cabinet and brought online in minutes, and individual UPSs can be isolated and swapped out for maintenance—significantly reducing installation and maintenance expenses.