PP887S 3BSE092987R1备件库存
如果是的话,问题很可能是由某个值和持续时间的电源下降引起的。这可能会导致控制单元中的一个内部继电器断开,从而模拟故障状况。这是极不可能发生的情况,不需要采取补救措施。在问题持续存在的异常情况下,可能需要采取措施以确保向垫子系统提供更顺畅的电源。8.6维修在垫系统或机器控制系统上工作之前,隔离机器和垫系统的电源。遵守电气安全预防措施。用户维修仅限于更换新的垫系统部件。如果出现问题,应将装置退还给供应商。应使用推荐的对接拼接接头对连接线进行任何维修。篡改零部件将使保修失效。如果DIN导轨控制单元上的质量封条损坏,则保修无效。39可用备件对于特殊尺寸的传感器垫,请参阅标签上打印的型号。更换任何零件后,必须进行8.2所示的检查和测试,并特别注意更换的零件。警告:维护或维修操作后,必须正确重新安装所有镶边、紧固件和电缆保护装置。不这样做或使用未经批准的零件或修改可能导致垫子系统无法达到其规定性能。8.7服务如需服务和协助,请联系供应商。尺寸型号周边饰件指定长度MGT 3010两件式周边饰件指定MGT 3011(带电缆干线)单元饰件指定长度MG T 3020保护电线导管指定长度MGG 3030垫子控制单元MGCP1 MGCS1 MGCD1 MGCSM1与MGCD1系统备件套件描述零件号2保险丝500mA(T)
f they are, the problem is likely to be caused by a dip in supply power of a certain value and duration. This can cause one of the internal relays in the control unit to drop out, thus simulating a fault condition. This is a very unlikely occurrence and no remedial action is required. In the unusual event of the problem persisting, measures may be required to ensure a smoother power supply to the mat system. 8.6 REPAIR Prior to working on the mat system or machine control system, isolate power source to the machine and mat system. Observe electrical safety precautions. User repairs are limited to replacement by new mat system parts. In the event of problems, the units should be returned to the supplier. Any repairs to the connecting wires should be made using the recommended butt splice connectors. TAMPERING WITH COMPONENT PARTS WILL INVALIDATE WARRANTY. WARRANTY INVALID IF QUALITY SEAL IS BROKEN ON DIN RAIL CONTROL UNIT. 39 AVAILABLE SPARES For special sized sensor mats, refer to the model no. printed on the label. After replacing any parts the inspection and test shown at 8.2 must be carried out with special attention given to those parts replaced. WARNING After maintenance or repair operations it is important that all edging trims, fastenings and cable protection are correctly refitted. Failure to do this or the use of non approved parts or modifications may result in the mat system failing to achieve its specified performance. 8.7 SERVICE For service and assistance please contact the supplier. Size Model No. Perimeter trim Specify length MGT 3010 Twp piece perimeter trim Specify length MGT 3011 (with cable trunk) Uniting trim Specify length MGT 3020 Protective wire guide Specify length MGT 3030 Mat Control unit MGCP1 MGCS1 MGCD1 MGCSM1 Remote indication unit for use with MGCD1 MGRID1 System Spares Kit Description Part No. 2 Fuses 500mA(T)