FCP270 P0917YZ系统备件
此配置允许忽略短暂的光束中断。使用双扫描模式时,响应时间会增加。教学说明模拟输出自动缩放到连接阵列的长度。如果没有光束中断,则模拟输出为最小值(4 mA或0V);如果顶部(最后)光束中断(在绝对/位置模式下)或所有光束中断(相对/尺寸模式下),模拟输出处于最大值(20 mA或10V),在这些状态之间的条件下具有直线斜率。这意味着大多数应用程序不需要设定设备。对于需要自定义缩放输出的应用程序,请使用以下教学步骤。扩展PCB上的示教按钮和远程示教输入(输入1)都使用相同的示教程序。将DIP开关S1:3设置为ON(并循环电源),以启用远程示教输入。使用远程设定时,如果指示指示“按住设定按钮5秒”,则输入必须打开至少5秒。1.开始示教按住示教按钮约5秒,直到状态指示器D15开始每3秒闪烁一次,这表明装置处于示教模式。2.设定最小模拟输出(4 mA或0V)将要由最小模拟输出表示的对象放置在阵列内。按下并松开设定按钮。状态指示灯D15现在每3秒闪烁两次,表示已识别到任何中断的光束。如果没有光束中断,运行模式下的最小模拟输出值(4 mA或0V)表示没有光束中断。
This configuration allows brief beam interruptions to be ignored. When using double scan mode, the response time is increased. Teach Instructions The analog output is automatically scaled to the length of the connected arrays. If no beams are interrupted, the analog output is at the minimum (4 mA or 0V); if the top (last) beam is interrupted (in absolute/position mode) or all beams are interrupted (in relative/size mode), the analog output is at the maximum (20 mA or 10V) with a straight-line slope for conditions in between those states. This means that most applications do not require teaching the device. For applications that do require customized scaling of the output use the following teach steps. The Teach button on the extension PCB and the remote teach input (Input 1) both use the same teach procedure. Set DIP switch S1:3 to ON (and cycle power) to enable the remote teach input. When using the remote teach, if the instructions indicate “Press and hold the Teach button for 5 seconds” the input must be turned ON for at least 5 seconds. 1. Start teach Press and hold the Teach button for approximately 5 seconds until status indicator D15 begins flashing once every 3 seconds, which indicates that the unit is in teach mode. 2. Teach minimum analog output (4 mA or 0V) Place the object that is to be represented by the minimum analog output within the arrays. Press and release the Teach button. Status indicator D15 now flashes twice every 3 seconds, which indicates that any interrupted beams have been recognized. If no beams are interrupted, the minimum analog output value (4 mA or 0V) in Run mode indicates that no beams are interrupted.