S-076N 3BHB009884R0021工控模块系统备件

S-076N 3BHB009884R0021工控模块系统备件

S-076N 3BHB009884R0021工控模块系统备件型号:440F-C4000P R 3 A1•+重置IND 1 2 MC Y1 Y3 Y5••13 23 31 A2——重置IND 3 4 MC Y2 Y4 Y6••14 24 32 110/230VAC可选24V AC/DC440F-C4000D EN 1760-1,EN 954-1第3类响应时间:35mS英国制造电源自动复位模式手动复位...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

S-076N 3BHB009884R0021工控模块系统备件

    S-076N 3BHB009884R0021工控模块系统备件

    型号:440F-C4000P R 3 A1•+重置IND 1 2 MC Y1 Y3 Y5••13 23 31 A2——重置IND 3 4 MC Y2 Y4 Y6••14 24 32 110/230VAC可选24V AC/DC440F-C4000D EN 1760-1,EN 954-1第3类响应时间:35mS英国制造电源自动复位模式手动复位模式机器启用R 83HA A300 IND CONT EQ MatGuard打开前隔离控制单元标记MGCD1控制单元标记440F-C4000P和440F-C400S注意:复位按钮的位置与440F-C4000 S控制单元标记440 F-C28013上的位置不同简介压敏垫系统设计供专业人员在工业环境中用作安全产品。当操作员在危险区域附近时,可通过隔离电源消除危险。本手册涵盖了系统所有部件的安装和使用,包括特殊形状和尺寸的传感器垫。所有安装程序应由经过适当培训的合格人员执行,并应符合法定安全要求。安装前请完整阅读本手册。安装后,应将本手册保存在安全且可接近的地方。如需进一步帮助,请联系供应商。第1节-储存和搬运1.1储存控制装置和垫传感器应储存在-40°C至+70°C的温度范围内。垫子传感器应垂直存放。1.2搬运和运输控制装置和垫传感器应在-40°C至+70°C的温度范围内运输。应使用原始包装或类似包装,必要时应加固,以防止损坏和弯曲。始终小心打开包装,避免被刀具等损坏。当传感器垫移动到位时,切勿通过其连接线拉动或提起传感器。对于较大的传感器垫,需要两个人才能安全起吊并防止传感器垫因过度弯曲而损坏。4第2节-系统描述系统包括一个或多个互连的压敏垫和一个控制单元。检测区域内没有“死区”。rec中提供了单独的传感器垫部分矩形标准尺寸,也有专门切割的形状,可达到最大标准垫的尺寸。所有传感器垫具有相同的结构和操作原理。每个垫子都有两个导电板,它们由非导电的可压缩隔板隔开。这些垫子在24V DC下工作,并串联在一起,以形成机器周围危险区域的地面感应系统。通过垫的电路由控制单元监控,当区域空闲时,控制单元向机器控制电路提供信号。当踏上任何垫子时,导电板接触,电路中的电阻下降。这由关闭机器的控制单元监控。将检测到垫、接线或控制单元中的任何单个电气故障,并且控制单元输出将进入安全(OFF)状态。

    Model: 440F-C4000P R 3 A1 •+Reset IND 1 2 MC Y1 Y3 Y5 • • 13 23 31 A2 - Reset IND 3 4 MC Y2 Y4 Y6 • • 14 24 32 110/230VAC Optional 24V AC/DC440F-C4000D EN 1760-1, EN 954-1 Type 3 response time: 35mS British made power supply Automatic reset mode Manual reset mode Machine enable R 83HA A300 IND CONT EQ MatGuard Isolate control unit mark MGCD1 Control unit mark 440F-C4000P and 440F-C400S Note: The position of reset button is different from that on 440F-C4000 S Control unit mark 440 F-C28013 Brief introduction Pressure sensitive pad system is designed for professionals to use as safety products in industrial environment. When the operator is near the danger area, the danger can be eliminated by isolating the power supply. This manual covers the installation and use of all components of the system, including sensor pads with special shapes and sizes. All installation procedures shall be carried out by suitably trained and qualified personnel and shall comply with statutory safety requirements. Please read this manual completely before installation. After installation, keep this manual in a safe and accessible place. For further assistance, please contact the supplier. Section 1 - Storage and Handling 1.1 Storage controls and pad sensors shall be stored in a temperature range of - 40 ° C to+70 ° C. Cushion sensors should be stored vertically. 1.2 The handling and transportation control devices and pad sensors shall be transported within the temperature range of - 40 ° C to+70 ° C. The original packaging or similar packaging shall be used, and if necessary, it shall be reinforced to prevent damage and bending. Always open the package carefully to avoid being damaged by knives, etc. When the sensor pad moves in place, do not pull or lift the sensor through its connecting wire. For larger sensor pads, two people are required to lift safely and prevent damage to the sensor pads due to excessive bending. 4 Section 2 - System Description The system consists of one or more interconnected pressure sensitive pads and a control unit. There is no "dead zone" in the detection area. The rec provides a separate rectangular standard size of the sensor pad, as well as a specially cut shape, which can reach the maximum standard pad size. All sensor pads have the same structure and operating principle. Each cushion has two conductive plates, which are separated by non-conductive compressible partitions. These pads work at 24V DC and are connected in series to form a ground sensing system in the hazardous area around the machine. The circuit through the pad is monitored by the control unit, which provides signals to the machine control circuit when the area is free. When stepping on any mat, the conductive plate contacts and the resistance in the circuit decreases. This is monitored by the control unit that shuts down the machine. Any single electrical fault in the pad, wiring or control unit will be detected, and the control unit output will enter the OFF state.

    20.jpg

    16.jpg

    23.jpg



    品牌:ABB

    型号:S-076N 3BHB009884R0021 

    质保:365天

    成色:全新/二手

    发货方式:快递发货


图片名 客服

在线客服 客服一号