VMIVME-6016工控模块系统备件
周围编织
其他电缆之间或周围编织。•在电缆之间留出至少10%的间隙,以便它们能够自由移动。在电缆之间使用分离器。•电缆必须能够在托架内自由移动。请勿将电缆连接到托架或彼此。将电缆夹在托架端部之外。夹紧前,将托架循环几次。•将较重的电缆夹向轨道边缘,将较轻的电缆夹在轨道中心。•不要将电缆紧紧拉在内侧/外侧轨道弯道上。隔板连接器组件下图显示了隔板连接器的侧视图,该连接器通过螺钉连接,并突出穿过法兰和导电壁(如金属柜)。前视图显示了连接的隔板连接器的引脚穿过墙壁。AB配对导电(金属)壁连接器二次成型外形,黑色pvc B ED C 18-1 I A G F J H前视图侧视图17出版物1326A-2.11-1998年5月通过机柜壁安装隔板
安装隔板连接器准备机柜壁:
1.确定将安装隔板连接器的机柜壁区域。2.标记四个安装孔和中心连接器开口的位置。3.钻四个安装孔和大中心开口。4.从1326-CPB1-E-xxx、1326-CPB1T-E-xxx、1326-CPR1-E-xxx或1326-CPC1T-E-xxx电缆的隔板法兰将接触的机柜壁内表面刮去任何油漆。注:所有B系列电缆连接器都经过黑色、高导电性钴涂层处理。不要刮擦涂层。重要提示:金属对金属连接必须符合CE合规标准。5.从1326 CCU EL xxx、1326-CPB1-EL-xxx和1326-CPC1-EL-xxx电缆的连接器表面上拆下viton密封,为机柜壁提供间隙。机柜壁的连接应为IP65。6.将隔板连接器穿过墙壁,如图所示:!注意:为避免电击危险,在安装或拆除电缆之前,应切断电机控制器和电机的电源。否则可能导致人身伤害。
Weaving around
Braiding between or around other cables. • Leave at least 10% clearance between cables so that they can move freely. Use separators between cables. • The cable must be able to move freely in the tray. Do not connect the cables to the tray or to each other. Clamp the cable out of the end of the tray. Cycle the bracket several times before clamping. • Clamp the heavier cable to the edge of the track and the lighter cable to the center of the track. • Do not pull the cable tightly on the inner/outer track curve. The following figure of the bulkhead connector assembly shows a side view of the bulkhead connector, which is connected by screws and protrudes through flanges and conductive walls (such as metal cabinets). The front view shows the connected bulkhead connector pins through the wall. AB paired conductive (metal) wall connector secondary molding shape, black pvc B ED C 18-1 I A G F J H front view side view 17 publication 1326A-2.11-May 1998, partition was installed through cabinet wall
Install the bulkhead connector Prepare the cabinet wall:
1. Determine the cabinet wall area where the bulkhead connector will be installed. 2. Mark the position of four mounting holes and central connector opening. 3. Drill four mounting holes and large center openings. 4. Scrape off any paint from the partition flange of 1326-CPB1-E-xxx, 1326-CPB1T-E-xxx, 1326-CPR1-E-xxx or 1326-CPC1T-E-xxx cable on the inner surface of the cabinet wall. Note: All B series cable connectors are coated with black, high conductivity cobalt. Do not scratch the coating. Important: Metal to metal connections must comply with CE compliance standards. 5. Remove the viton seal from the connector surface of the 1326 CCU EL xxx, 1326-CPB1-EL-xxx and 1326-CPC1-EL-xxx cables to provide clearance for the cabinet wall. The connection of cabinet wall shall be IP65. 6. Pass the bulkhead connector through the wall, as shown in the figure:! Note: To avoid the risk of electric shock, cut off the power supply of the motor controller and motor before installing or removing the cable. Failure to do so may result in personal injury.