WOODWARD 9907-105自动化工控模块
计算机型号目录
编号区域额定温度范围非显示非显示型号:限制表(U)•对于EPL Gc,工业计算机应完全安装在防护等级最低为IP54的外壳中,并在不超过2级污染的区域使用。对于EPL Dc,要求最低防护等级为IP6x。此外,外壳还应满足EN/IEC 60079-0:2012/2011、EN/IEC 6009-15:2010和EN/IEC 0079-31:2014/2013的适用外壳要求。•除非已知该区域无危险,否则不得使用USB端口。除非已知该区域无危险,否则不得断开所有其他端口或连接。(2) 以下内容仅适用于ATEX和IECEx应用中的显示器型号:安全使用特殊条件(X)•对于EPL Gc,工业计算机应安装在外壳的墙壁中,提供最低防护等级IP54,并用于不超过2级污染的区域。对于EPL Dc,要求最低防护等级IP6x。
外壳要求
外壳还应满足适用外壳要求。•当用户考虑外壳内所有其他热源的加热时,安装6181X-12T显示模型的外壳的工作温度不得超过70°C(158°F)。•除非已知该区域无危险,否则不得使用USB端口。除非已知该区域无危险,否则不得断开所有其他端口或连接。(3) 整个非显示计算机和显示计算机的背面需要安装在受限的访问位置。安装以下声明适用于在危险场所使用计算机时。热表面受限访问位置验证受限访问设备的位置满足以下条件:•只能由服务人员或已被告知限制某个位置的原因以及需要采取的预防措施的用户进入。•访问是通过使用工具、锁和钥匙,或由负责地点的机构控制的其他安全手段。警告:爆炸危险•更换部件可能会影响危险场所的适用性。
Computer Model Directory
The rated temperature range of the numbered area is non display and non display model: restriction table (U) • For EPL Gc, the industrial computer should be completely installed in the enclosure with the lowest protection level of IP54, and used in the area with no more than level 2 pollution. For EPL Dc, the minimum protection level is required to be IP6x. In addition, the enclosure shall meet the applicable enclosure requirements of EN/IEC 60079-0:2012/2011, EN/IEC 6009-15:2010 and EN/IEC 0079-31:2014/2013. • The USB port must not be used unless the area is known to be non hazardous. Do not disconnect all other ports or connections unless the area is known to be hazard free. (2) The following applies only to monitor models in ATEX and IECEx applications: special conditions for safe use (X) • For EPL Gc, the industrial computer should be installed in the wall of the enclosure, with a minimum protection level of IP54, and used in areas not more than level 2 pollution. For EPL Dc, the minimum protection level IP6x is required.
Enclosure requirements
The enclosure shall also meet the applicable enclosure requirements. • When the user considers the heating of all other heat sources in the enclosure, the operating temperature of the enclosure where the 6181X-12T display model is installed shall not exceed 70 ° C (158 ° F). • The USB port must not be used unless the area is known to be non hazardous. Do not disconnect all other ports or connections unless the area is known to be hazard free. (3) The entire non display computer and the back of the display computer need to be installed in a restricted access location. Install the following statements for use in hazardous locations. Hot surface restricted access location Verify that the location of the restricted access device meets the following conditions: • Only service personnel or users who have been informed of the reason for restricting a location and the precautions to be taken can enter. • Access is through the use of tools, locks and keys, or other security means controlled by the agency responsible for the location. WARNING: EXPLOSION HAZARD • REPLACEMENT OF COMPONENTS MAY IMPACT THE SUITABILITY IN HAZARDOUS LOCATIONS.