Woodward 9907-1200备件模块
安装注意事项
在安装计算机之前,请阅读并遵循这些注意事项。环境和外壳信息欧盟指令此计算机在安装时符合欧盟指令要求在欧盟或EEA地区,并具有CE标志。符合性声明的副本可在证明为了符合要求,电缆类型应采用以下标准。注意:本设备适用于污染等级为2级的工业环境、II类过电压应用(如IEC 60664-1中所定义)、海拔2000米(6561英尺)以下且不降额的环境。根据IEC/CISPR 22,该设备被视为第1组A类工业设备。如果没有适当的预防措施,由于传导干扰和辐射干扰,在其他环境中的电磁兼容性可能存在潜在困难。该设备作为开放式设备提供。为了满足某些法规要求,计算机必须安装在一个外壳中,该外壳针对可能存在的环境条件进行了适当设计,并进行了适当的设计,以防止因接触带电部件而造成人身伤害。
接地指南
必须使用工具才能接近外壳内部。所有6181X-12显示计算机均配有垫圈挡板,仅当安装在具有同等额定值的面板或外壳中时,才能满足指定的NEMA、UL类型和IEC额定值。除本出版物外,请参阅以下内容:•工业自动化布线和接地指南,出版物1770-4.1,了解其他安装要求•NEMA标准250、UL 50和IEC 60529(如适用),了解外壳提供的防护等级说明注意:符合EN 55022和EN 55024,所有I/O电缆必须小于30米(98.42英尺),并且只能在室内使用。这些电缆在任何时候都不能离开建筑物,也不能直接连接到建筑物外的电缆。所需电缆类型属性电缆类型所需属性LAN屏蔽或非屏蔽DP屏蔽USB屏蔽VGA屏蔽串行RS-232屏蔽直流电源非屏蔽DVI屏蔽自动化出版物安装第2章危险场所本设备适用于这些场所类别。
Installation precautions
Read and follow these precautions before installing your computer. Environment and Enclosure Information EU Directives This computer meets the requirements of EU Directives when installed in the EU or EEA region, and has the CE mark. A copy of the declaration of conformity can be used to prove that the following standards shall be adopted for cable types in order to meet the requirements. Note: This equipment is applicable to industrial environment with pollution level of 2, overvoltage application of Class II (as defined in IEC 60664-1), and environment with altitude below 2000 meters (6561 feet) and no derating. According to IEC/CISPR 22, this equipment is considered as Group 1 Class A industrial equipment. Without proper preventive measures, electromagnetic compatibility in other environments may have potential difficulties due to conducted interference and radiated interference. The device is provided as an open device. In order to meet certain regulatory requirements, the computer must be installed in an enclosure that is properly designed for possible environmental conditions and is designed to prevent personal injury due to contact with live parts.
Grounding Guidelines
Tools must be used to access the inside of the enclosure. All 6181X-12 display computers are equipped with a gasket bezel that meets the specified NEMA, UL type, and IEC ratings only when installed in an equally rated panel or enclosure. In addition to this publication, refer to the following: • Industrial Automation Wiring and Grounding Guidelines, Publication 1770-4.1, for additional installation requirements • NEMA Standard 250, UL 50, and IEC 60529 (as applicable), for the degree of protection provided by enclosures Note: Comply with EN 55022 and EN 55024, all I/O cables must be less than 30 meters (98.42 feet), and can only be used indoors. These cables cannot leave the building at any time, nor can they be directly connected to the cables outside the building. Required Cable Type Properties Required Cable Type Properties LAN Shielded or Unshielded DP Shielded USB Shielded VGA Shielded Serial RS-232 Shielded DC Power Unshielded DVI Shielded Automation Publication Installation Chapter 2 Hazardous Locations This equipment is applicable to these site categories.