PPC907BE 3BHE024577R0101模块备件
电机放大器
注意:接触器必须垂直安装。不遵守此安装规程将导致接触器操作不当,并可能导致人身伤害。出版物1370-IN011B-EN-P 1370直流回路接触器和接线片套件3图1近似尺寸和重量抑制器安装所提供的浪涌抑制器将减少可能影响驱动性能的噪声干扰。按照以下说明将抑制器安装在接触器线圈上。重要提示:如果对抑制器施加的交流电超过132V,可能会损坏部件。1.松开线圈端子夹。2.将浪涌抑制器滑到线圈端子上。3.将线圈电路导线置于抑制器端子和线圈端子夹之间。4.牢固拧紧线圈端子夹。接线图2显示了典型的接线图。出版物1370-IN011B-EN-P 4 1370直流回路接触器和接线片套件图2典型接触器接线图3接触器端子位置线连接负载连接控制电路端子上前连接跳线带注释辅助。
14号AWG电线向上
(Uppe)的电线端子DB电阻器连接上前负载端子A1+控制电路端子(最大14 AWG)上后线路端子DC-(1)上前负载终端A2线圈端子辅助触点,N.O.上后线路终端DC+(1)DB电阻器端子(使用时)(1)后端子螺栓可用于母线连接。出版物1370-IN011B-EN-P 1370直流回路接触器和接线片套件5在连接动态制动电阻器时,使用电流容量至少为电机满载额定电流的1/2的导线。重要:有关动态制动电阻器应用的导线尺寸和类型的具体指南,请参考国家电气规范和当地规范。辅助触点辅助触点组件可用于所有接触器额定值。
Motor amplifier
Note: The contactor must be installed vertically. Failure to follow this installation procedure will result in improper operation of the contactor and may cause personal injury. Publication 1370-IN011B-EN-P 1370 DC Loop Contactor and Lug Kit 3 Figure 1 Approximate Dimensions and Weights The surge suppressor provided for installation will reduce noise interference that may affect drive performance. Follow the instructions below to install the suppressor on the contactor coil. Important: If the AC power applied to the suppressor exceeds 132V, components may be damaged. 1. Loosen the coil terminal clip. 2. Slide the surge suppressor onto the coil terminal. 3. Place the coil circuit wire between the suppressor terminal and the coil terminal clip. 4. Tighten the coil terminal clamp firmly. Wiring diagram 2 shows a typical wiring diagram. Publication 1370-IN011B-EN-P 4 1370 DC Loop Contactor and Lug Kit Figure 2 Typical Contactor Wiring Diagram 3 Contactor Terminal Location Wire Connection Load Connection Front Connection Jumper on Control Circuit Terminal with Note Aid.
14 AWG wire up
The wire terminal DB resistor of (Uppe) is connected to the front load terminal A1+the rear line terminal DC on the control circuit terminal (maximum 14 AWG) - (1) the auxiliary contact of the front load terminal A2 coil terminal on the N.O., and the rear line terminal DC+(1) DB resistor terminal (when used) (1) the rear terminal bolt can be used for bus connection. Publication 1370-IN011B-EN-P 1370 DC Loop Contactor and Lug Kit 5 When connecting dynamic braking resistors, use conductors with a current capacity of at least 1/2 of the motor's full load rated current. IMPORTANT: Refer to the National Electrical Code and local codes for specific guidelines on wire sizes and types for dynamic braking resistor applications. Auxiliary contact Auxiliary contact assemblies are available for all contactor ratings.