DS200TCEAG1BSF工控模块系统备件
固件存储
使用此闪存是可选的。闪存中的固件存储此CPU使用非易失性闪存存储操作系统固件。这允许在不拆卸模块或更换EPROM的情况下更新固件。通过将PC兼容计算机连接到模块的串行端口并运行随附的软件来更新操作系统固件电源(PWR724/PWR748),如下图所示。环境温度()C 10 100W 10W 20W 60W 80W 90W 50W 40W 30W正常工作范围无强制空气循环20 30 40 50 60 55 PWR711 PWR724 PWR748 90W 60W 75W安装OEM、系统集成商或最终用户有责任正确安装PLC设备,确保安全可靠运行。产品手册提供了有关PLC设备安装、启动和正确使用的详细信息。PLC编程软件附带的安装手册描述了如何正确安装设备。
中央处理单元
96 MHz、32位、浮点、1 Mbyte内存中央处理单元GFK-1431F PLC CPU 1999年11月系列90-70可编程控制器数据表手册GFK-0600F 20-3如果PLC安装必须符合支持的标准,如FCC或CE指令,请参阅PLC编程软件附带的符合标准的安装要求,了解更多指南。未参考适用的可编程控制器安装手册,不得尝试安装。将电池连接至模块上的任一电池连接器(见图2)。将拨动开关置于停止位置。将钥匙开关置于记忆保护断开位置。确保机架电源已关闭。将CPX 782模块安装在机架0的插槽1中(见图1)。打开电源。模块应通电,左上角(OK)LED应闪烁。诊断成功完成后,左上角的LED保持点亮,第二个(运行)和第三个(EN)LED熄灭。如果钥匙开关处于off位置,则第四个(左下角)LED(MEM PROTECT)熄灭。
Firmware storage
The use of this flash memory is optional. Firmware storage in flash This CPU uses non-volatile flash to store operating system firmware. This allows the firmware to be updated without removing the module or replacing the EPROM. Update the operating system firmware power supply (PWR724/PWR748) by connecting a PC compatible computer to the serial port of the module and running the accompanying software, as shown in the following figure. Ambient temperature () C 10 100W 10W 20W 60W 80W 90W 50W 40W 30W No forced air circulation in normal working range 20 30 40 50 60 55 PWR711 PWR724 PWR748 90W 60W 75W Installation OEM, system integrator or end user are responsible for correctly installing PLC equipment to ensure safe and reliable operation. The product manual provides detailed information about the installation, startup and proper use of the PLC equipment. The installation manual included with the PLC programming software describes how to properly install the equipment.
Central processing unit
96 MHz, 32-bit, floating point, 1 Mbyte memory central processing unit GFK-1431F PLC CPU November 1999 Series 90-70 Programmable Controller Data Sheet Manual GFK-0600F 20-3 If the PLC installation must conform to the supported standards, such as FCC or CE instructions, please refer to the standard installation requirements attached to the PLC programming software for more guidance. Do not attempt to install without referring to the applicable PLC installation manual. Connect the battery to any battery connector on the module (see Figure 2). Place the toggle switch in the STOP position. Place the keyswitch in the memory protection OFF position. Make sure the rack is powered off. Install the CPX 782 module in slot 1 of rack 0 (see Figure 1). Turn on the power. The module should be powered and the upper left (OK) LED should flash. After successful diagnosis, the LED in the upper left corner remains on, and the second (running) and third (EN) LEDs go out. If the key switch is in the off position, the fourth (lower left) LED (MEM PROTECT) goes out.