330161-02-85-05-94-01-02输入输出模块

330161-02-85-05-94-01-02输入输出模块

330161-02-85-05-94-01-02输入输出模块接线欧式连接器要将接线板从底座上拆下,请松开将接线板固定到底座上的螺钉,然后牢牢抓住接线板并拉动。不要用导线将块拉出,因为这可能会松开或损坏导线或连接器。典型输入/输出模块参考3301现场接线图包了解推荐接线。此外,不要从导线上去除超过6毫米(0.25英寸)的绝缘层。3301/20操作和维护4 I/O模块说明25 4.1.4电缆引脚输出电...

  • 功能特性
  • 参数规格
  • 视频
  • 应用案例
  • 下载

330161-02-85-05-94-01-02输入输出模块

    330161-02-85-05-94-01-02输入输出模块

    接线欧式连接器

    要将接线板从底座上拆下,请松开将接线板固定到底座上的螺钉,然后牢牢抓住接线板并拉动。不要用导线将块拉出,因为这可能会松开或损坏导线或连接器。典型输入/输出模块参考3301现场接线图包了解推荐接线。此外,不要从导线上去除超过6毫米(0.25英寸)的绝缘层。3301/20操作和维护4 I/O模块说明25 4.1.4电缆引脚输出电缆编号02290860主机(或机架接口模块)至外部调制解调器电缆编号130118--主机至3301机架RS-232接口电缆4 I/O模块描述3301/20运行和维护26电缆编号132632--主计算机至3301机架电缆RS-422 PVC电缆编号132633--主机至3301机架电缆RS-422 Teflon 3301/20操作和维护4 I/O模块说明27电缆编号130119-01主机至RS-232/422转换器电缆编号130120-- RS-232/42转换器至3301机架线缆(RS-422)-PVC绝缘4 I/O模块描述3301/20操作和维护28电缆编号130121-- RS-422延长电缆电缆编号130122-- RS-422 3301机架至3301机架电缆-PVC绝缘3301/20操作和维护4 I/O模块说明29电缆编号131106-- RS-232/422转换器至3301机架线缆(RS-422)-特氟龙绝缘电缆编号131107--RS-422 350机架至3301架架电缆-特氟隆绝缘4 I/O模块描述3301/20运行和维护30 4.2数据管理器I/O模块Data Manager I/O模块必须安装在电源输入模块和机架接口I/O模块之间的电源后面(在机架安装或面板安装机架中)或电源输入模块与机架接口I/O模件之间的电源上面(在隔板机架中)。数据管理器I/O模块的功能是将3301机架连接到TDI或DDI通信处理器。每个端口最多可连接24个通道,从3301机架到通信处理器。有关可用的不同选项,请参阅第10页的表格。1) 用于将静态信息从3301机架的端口1传输至通信处理器上的静态连接器。2) 用于将动态信息从3301机架的端口1传输至通信处理器上的动态连接器。3) 用于将信息从3301机架的端口2传输至通信处理器上的静态连接器。4) 用于将动态信息从3301机架的端口2传输至通信处理器上的动态连接器。

    注:3301监测系统支持DDI和TDI通信处理器。

    注:如果拆除机架接口模块,数据管理器I/O将停止运行。3301/20操作和维护4输入/输出模块说明31 4.2.1电缆引脚输出电缆编号129386-01 3301静态至TDI电缆电缆编号12937-01 3301静态至DDI电缆4输入/输入模块说明3301/20运行和维护32电缆编号02290160动态数据电缆DDI/TDI 3301/40操作和维护5维护33 5维护本节说明如何验证机架接口模块和I/O模块工作正常。正确执行时,可在机架通电时将该模块安装到机架中或从机架中卸下。有关正确程序,请参阅机架安装和维护手册(零件号129766-01)。5.1 RIM主机端口测试实用程序使用RIM主机接口测试实用程序验证机架接口模块和机架接口输入/输出模块上的主机端口是否正常工作。在运行RIM主机端口测试实用程序之前,将电缆130118--(主机至3301机架RS-232接口电缆)连接在机架接口模块前面的配置端口连接器或机架接口I/O模块上的主机连接器与安装了该实用程序的计算机之间。有关该实用程序的详细信息,请参阅3301监测系统机架配置和实用程序指南和机架配置软件。5.2执行固件升级有时可能需要更换3301/20机架接口模块(RIM)附带的原始固件。以下说明描述了如何删除现有固件并将其替换为升级固件。固件升级后,RIM需要使用3301机架配置软件重新配置。执行RIM固件升级需要以下项目:大型平头螺丝刀。接地腕带*小型平头螺丝刀升级固件IC。**有关零件号,请参阅第7节(订购信息)。用户可以使用自己的接地腕带。5.2.1安装程序完成以下步骤

    Wiring European connector

    To remove the terminal block from the base, loosen the screw that secures the terminal block to the base, then firmly grasp the terminal block and pull. Do not pull the block out with wires as this may loosen or damage the wires or connectors. Refer to the 3301 Field Wiring Diagram Package for typical I/O modules for recommended wiring. Also, do not remove more than 6 mm (0.25 in) of insulation from the wire. 3301/20 Operation and Maintenance 4 I/O Module Description 25 4.1.4 Cable Pin Output Cable Number 02290860 Host (or Rack Interface Module) Cable number to external modem 130118 -- Host computer to 3301 rack RS-232 interface cable 4 I/O module description 3301/20 operation and maintenance 26 Cable number 132632 -- Host computer to 3301 rack cable RS-422 PVC cable number 132633 -- Host computer to 3301 rack cable RS-422 Teflon 3301/20 operation and maintenance 4 I/O module description 27 Cable number 130119-01 Host computer to RS-232/422 converter cable number 130120 -- RS-232/42 converter to 3301 rack cable (RS-422) -PVC insulated 4 I/O module description 3301/20 Operation and maintenance 28 Cable number 130121 -- RS-422 extension cable number 130122 -- RS-422 3301 rack to 3301 rack cable PVC insulated 3301/20 Operation and maintenance 4 I/O module description 29 Cable number 131106 -- RS-232/422 converter to 3301 rack cable (RS-422) -Teflon insulated cable No. 131107 -- RS-422 350 rack to 3301 rack cable - Teflon insulated 4 I/O module description 3301/20 Operation and maintenance 30 4.2 Data manager I/O module Data Manager I/O module must be installed behind the power supply between the power input module and the rack interface I/O module (in a rack mounted or panel mounted rack) or above the power supply between the power input module and the rack interface I/O module (in a bulkhead rack). The function of the data manager I/O module is to connect the 3301 rack to the TDI or DDI communication processor. Each port can connect up to 24 channels, from the 3301 rack to the communication processor. See the table on page 10 for the different options available. 1) Used to transfer static information from port 1 of the 3301 rack to the static connector on the communication processor. 2) Used to transmit dynamic information from port 1 of the 3301 rack to the dynamic connector on the communication processor. 3) Used to transfer information from port 2 of the 3301 rack to a static connector on the communication processor. 4) Used to transmit dynamic information from port 2 of the 3301 rack to the dynamic connector on the communication processor.

    Note: 3301 monitoring system supports DDI and TDI communication processors. 

    Note: If you remove the Rack Interface Module, the Data Manager I/O will stop. 3301/20 Operation and maintenance 4 I/O module description 31 4.2.1 Cable pin output cable number 129,386-01 3301 Static to TDI cable cable number 12,937-01 3301 Static to DDI cable 4 I/O module description 3301/20 Operation and maintenance 32 Cable number 02,290,160 Dynamic data cable DDI/TDI 3301/40 Operation and maintenance 5 Maintenance 33 5 Maintenance This section describes how to verify that the Rack Interface Module and I/O Module are working properly. When performed correctly, the module can be installed in or removed from the rack when the rack is powered up. Refer to the Rack Installation and Maintenance Manual (part number 129766-01) for the correct procedure. 5.1 RIM Host Port Test Utility Use the RIM Host Interface Test Utility to verify that the host ports on the Rack Interface Module and the Rack Interface I/O Module are working properly. Before running the RIM host port test utility, connect cable 130118 -- (host to 3301 rack RS-232 interface cable) between the configuration port connector on the front of the Rack Interface Module or the host connector on the Rack Interface I/O Module and the computer where the utility is installed. For more information about this utility, refer to the 3301 Monitoring System Rack Configuration and Utilities Guide and Rack Configuration Software. 5.2 Performing a firmware upgrade may sometimes require replacing the original firmware that came with the 3301/20 Rack Interface Module (RIM). The following instructions describe how to delete existing firmware and replace it with upgraded firmware. After the firmware upgrade, RIM needs to be reconfigured using the 3301 Rack Configuration Software. The following items are required to perform the RIM firmware upgrade: large flat screwdriver. Grounding wrist strap * small flat screwdriver to upgrade firmware IC** Refer to Section 7 (Ordering Information) for part numbers. Users can use their own grounding wrist strap. 5.2.1 The installation procedure completes the following steps

    微信图片_20211117105502.png

    f5a1d52084176089c442c690694264a9.jpg

    15.jpg



    品牌:BENTLY

    型号: 330161-02-85-05-94-01-02 

    产地:美国

    质保:365天

    成色:全新/二手

    发货方式:快递发货