37911-4-0338124 工控备件模块
典型
11.15(283)尺寸单位为英寸、毫米,括号内为19.00(483)18.11(460)17.04(433)*6.00(152.4)***a47122*.45(11)6.00(52.4)**侧视图6.00(153.4)***前视图*留出足够的水平间隙,以便在机架两端接地螺柱。如果使用延长电缆,请在机架左侧留出大约6英寸的水平间隙,以便接近连接器。*****IC697模块延伸1.7英寸。(43MM)超出机架前部,VME模块可能与机架前部齐平。7.25(184)9.14(232)电源接地螺柱连接器6.75(172)2.24(57).34(8.64).75(19)图1机架(后)安装机架安装的冗余机架尺寸机架必须按照上述方向安装。机架周围必须留有足够的空间,如图1和图2所示,以允许空气流用于模块冷却。机架式风扇组件(IC697ACC721(120 VAC)或IC697CCC724(240 VAC))可用于需要强制空气冷却的安装(有关风扇组件的详细信息,请参阅数据表GFK-0637)。
安装要求
(前安装或后安装)必须根据应用和订购的正确机架确定。安装法兰是机架侧面板的组成部分,在工厂安装。3个冗余机架,前后安装GFK-1447B PLC机架2000年1月这些机架可容纳两种I/O模块类型。首先,机架式IC697高密度I/O模块,使用可拆卸的现场接线端子板。每个I/O模块最多可接受40根AWG#14(2.10 mm2)导线。线束从端子板空腔的底部引出,在该空腔中提供了一个用于系带的夹板,以将线束固定到端子板外壳上。第二类模块是VME模块,其可能具有不同的连接现场设备的方法。*。265 x.437接地螺柱(如果需要额外冷却,可提供机架风扇组件(IC697ACC721或IC697CCC724)。11.15(283)尺寸以英寸、毫米为单位,括号内为19.00(483)18.34(466)17.04(433)6.00(152.4)***a47123*.45(11)6.00
Typical
11.15 (283) Dimensions are in inches and millimeters. In parentheses, it is 19.00 (483) 18.11 (460) 17.04 (433) * 6.00 (152.4) * * a47122 *. 45 (11) 6.00 (52.4) * * Side view 6.00 (153.4) * * * Front view * to leave enough horizontal clearance for grounding studs at both ends of the rack. If you are using an extender cable, leave approximately 6 inches of horizontal clearance on the left side of the rack for access to the connector***** The IC697 module extends 1.7 inches. (43MM) beyond the front of the rack, the VME module may be flush with the front of the rack. 7.25 (184) 9.14 (232) Power grounding stud connector 6.75 (172) 2.24 (57). 34 (8.64) 75 (19) Fig. 1 Rack (Rear) Mounting Rack The redundant rack dimensions for rack mounting must be installed in the above direction. Sufficient space must be left around the rack, as shown in Figures 1 and 2, to allow air flow for module cooling. Rack mounted fan assemblies (IC697ACC721 (120 VAC) or IC697CCC724 (240 VAC)) can be used for installations that require forced air cooling (refer to data sheet GFK-0637 for fan assembly details).
Installation requirements
(Front mount or rear mount) must be determined according to the application and the correct rack ordered. The mounting flange is an integral part of the rack side panel and is installed at the factory. Three redundant racks with GFK-1447B PLC racks installed at the front and rear. In January 2000, these racks can accommodate two types of I/O modules. First, the rack IC697 high-density I/O module uses removable field terminal blocks. Each I/O module can accept up to 40 AWG # 14 (2.10 mm2) conductors. The harness is led out from the bottom of the terminal board cavity, in which a clamp plate for tie wraps is provided to fix the harness to the terminal board housing. The second type of module is VME module, which may have different methods of connecting field devices. *. 265 x.437 grounding stud (if additional cooling is required, the rack fan assembly (IC697ACC721 or IC697CCC724) can be provided. 11.15 (283) Dimensions are in inches and millimeters, and the number in brackets is 19.00 (483) 18.34 (466) 17.04 (433) 6.00 (152.4) * * * a47123 *. 45 (11) 6.00