DSSR116 48990001-FK/2
为提高Profibus分辨率
已更改Profibus缩放功能。本补充说明了新的Profibus功能,以提高分辨率,并对Profibus主机进行必要的更改,以适应Tension Electronics PFEA113的更改。新的缩放功能适用于软件版本18及更高版本。本补充可与所有语言版本的用户手册《带张力电子设备的卷筒纸张力系统》PFEA113 3BSE029382R00一起使用。12其他菜单使用此菜单缩放Profibus测量值。参考用户手册PFEA113,3BSE029382R0001 B版,第31211节。图1-1。Profibus缩放,单辊或双辊快速设置WebTension演示菜单设置标称加载服务菜单零点设置包裹增益>5 s AO 1-AO 6其他菜单系统定义对象类型DO 1-DO 4 AI 1-AI 2 DI至其他菜单Profibus开/关[]Profibus地址[]现场总线开/关现场总线地址(仅在现场总线打开时显示)测量范围Roll 1(仅在Profibus打开时显示SetFactory Default AreYouSure ActionDone(显示1秒)LoadDivision N MeasuringRange N Measuring Range[]N Measering Range Roll 2(仅当Profibus打开时显示)LoadDivision N Meansuring Range NMeasuriing Range[]NFrom DI 1。Profibus缩放:在SystemDefinition中选择两个辊如果在SystemDefension Web Tension Systems with Tension Electronics PFEA113,Profibus Scaling,Supplement Chapter 1 Scaling Profibus Measuring Values 1-2 3BSE041811R0001 Figure 1-2中选择了一个辊,则不显示该菜单。Profibus伸缩,分段辊121 Profibus•Profibus开/关Profibus可启用或禁用。•Profibus地址?如果启用了Profibus,Profibus地址必须设置在000-125范围内。•Profibus测量范围?如果启用Profibus,Profibus测量范围和负载分配可以分别为Roll1和Roll2设置。阅读PFEA113用户手册第313122节Profibus测量值的缩放Profibus值可通过两种方式缩放:•默认缩放–缩放仅取决于称重传感器标称负载。•用户定义的缩放–用户可以设置Profibus值的缩放。
对于称重传感器
SetFactory Default AreYouSure ActionDone(显示1秒)MeasuringRange SegmentedRoll(仅当Profibus打开时显示)LoadDivision N Measuring Range N Measuriing Range[]N Miscellaneous Menu Profibus On/Off[]Profibus开/关2Profibus缩放:在带有张力电子设备PFEA113、Profibus Scaling、,补充第122节Profibus测量值的缩放3BSE041811R0001 1-3 1221默认缩放此功能与先前软件版本SW 10-17中的功能相似。称重传感器组合,LoadCellComb:一卷或两卷对于称重传感器组合一卷或二卷,默认缩放功能与先前的软件版本中的功能类似,SW 10-17。主要变化是差分信号。在SW 10-17中,差分信号具有单独的缩放。在SW18中,每个测量对象的所有信号具有相同的缩放比例。对于差异信号,当用SW18单元更换旧单元时,必须在Profibus主控器中调整负载缩放。负载传感器组合,LoadCellComb:分段滚动对于SW18,默认缩放功能与SW 10-17中的9至12个负载传感器功能(连接到模拟输出)类似,差异信号除外。对于3-8个称重传感器,当用SW18-uni替换旧单元时,必须在Profibus主控器中调整称重比例
To improve Profibus resolution
The Profibus zoom function has been changed. This supplement describes the new Profibus function to improve the resolution, and makes necessary changes to the Profibus host to adapt to the changes of Tension Electronics PFEA113. The new zoom function applies to software version 18 and later. This supplement can be used together with the user manual "Web Paper Force System with Tension Electronics" PFEA113 3BSE029382R00 in all languages. 12Other menus Use this menu to scale the Profibus measurements. Refer to User Manual PFEA113, 3BSE029382R0001 Rev. B, Section 31211. Figure 1-1. Profibus zoom, Single roller or double roller quick setting WebTension demo menu setting Nominal loading service menu Zero setting Package gain>5 s AO 1-AO 6 Other menus System definition Object type DO 1-DO 4 AI 1-AI 2 DI to other menus Profibus on/off [] Profibus address [] Fieldbus on/off Fieldbus address (displayed only when Profibus is on) Measurement range Roll 1 (displayed only when Profibus is on) (Displayed for 1 second) LoadDivision N Measuring Range N Measuring Range [] N Measuring Range Roll 2 (Displayed only when Profibus is turned on) LoadDivision N Measuring Range NMeasuring Range [] NFrom DI 1. Profibus scaling: select two rolls in SystemDefinition If a roll is selected in SystemDefinition Web Tension Systems with Tension Electronics PFEA113, Profibus Scaling, Supplement Chapter 1 Scaling Profibus Measuring Values 1-2 3BSE041811R0001 Figure 1-2, this menu will not be displayed. Profibus telescoping, segment roller 121 Profibus • Profibus on/off Profibus can be enabled or disabled. • Profibus address? If Profibus is enabled, the Profibus address must be set in the range 000-125. • Profibus measurement range? If Profibus is enabled, the Profibus measurement range and load distribution can be set for Roll1 and Roll2 respectively. Read PFEA113 User Manual Section 313122 Scaling of Profibus Measurements Profibus values can be scaled in two ways: • Default scaling – scaling depends only on the nominal load of the load cell. • User Defined Scaling – The user can set the scaling of the Profibus value.
For load cells
SetFactory Default AreYouSure ActionDone (displayed for 1 second) MeasureingRange SegmentedRoll (displayed only when Profibus is turned on) LoadDivision N Measuring Range N Measuring Range [] N Miscellaneous Menu Profibus On/Off, Added section 122 Scaling of Profibus measurements 3BSE041,811R0001 1-3 1221 Default Scaling This function is similar to the function in the previous software version SW 10-17. Load cell combination, LoadCellComb: One or two rolls For a load cell combination of one or two rolls, the default zoom function is similar to that in the previous software version, SW 10-17. The main change is the differential signal. In SW 10-17, the differential signal has a separate scaling. In SW18, all signals of each measuring object have the same scaling. For differential signals, when replacing the old unit with the SW18 unit, the load scaling must be adjusted in the Profibus master. Load sensor combination, LoadCellComb: segmented scrolling For SW18, the default zoom function is similar to the 9 to 12 load sensor functions (connected to analog output) in SW 10-17, except for differential signals. For 3-8 load cells, when replacing the old unit with SW18 uni, the weighing proportion must be adjusted in the Profibus master controller