3ASC25H219B工控卡件库存
CS31系统总线连接是电气隔离的来自其余模块组件。
该模块提供诊断功能(参见章节“诊断和显示”)。显示和连接
模块外壳1 16个黄色LED,用于显示信号状态输出2个LED“总线错误”、“过载”和“电源”指示操作条件和错误(参见“诊断和显示”部分)
3 CS31总线连接器(输入)
4 CS31总线连接器(输出)
5 16个输出连接器
6个PG11电缆密封套,用于24 V DC电源
7 24 V DC和PE的端子位于可拆卸的盖子。可以从顶部进入模块。用于设置模块的DIL开关地址也在封面下面。
8标签字段
9安装钻孔(另见“尺寸标注图纸”)
电气连接
下图显示了电气连接.寻址必须在每个模块上设置地址,以便中央单元可以正确访问输入和输出。
关于项目的详细描述“寻址”包含在章节中中央单元和耦合器的“寻址”。
模块地址设置在位于在模块顶部的盖子下面。使用中央控制单元07 KR 91、07 KT 92或07 KT 93,可能的模块地址范围为0...61.
与中央单元07 KR 91和07 KT 92/KT93作为总线主站,地址如下
分配有效:模块在CS31系统总线上使用16个输出。
I/O配置对于此模块,不需要I/O配置
正常操作模块在通电后初始化初始化所有指示灯都亮起。
初始化后,两个红色LED熄灭同样,如果总线运行正常,模块未检测到任何错误。绿色LED“电源”灯亮起。16个黄色LED指示通道A0…A15
The CS31 system bus connection is electrically isolated
from remaining module components.
The module offers diagnosis functions (see chapter
”Diagnosis and displays”).
Displays and connections at
module housing
1 16 yellow LEDs for displaying the signal statuses of
the outputs
2 LEDs ”Bus Error”, ”Overload” and ”Supply”
indicating of operating conditions and errors (see
section ”Diagnosis and displays”)
3 CS31 bus connector (input)
4 CS31 bus connector (output)
5 16 connectors for the outputs
6 PG11 cable gland for the 24 V DC power supply
7 The terminals for 24 V DC and PE are located under
a removable cover. It is accessible from the top of
the module. The DIL switch for setting the module
address is also under the cover.
8 Labelling fields
9 Bore holes for mounting (see also ”Dimensioned
drawing” at the end of this description)
Electrical connection
The following figure shows all details necessary for the
electrical connection.Addressing
An address has to be set on each module, so that the
central unit can access the inputs and outputs correctly.
A detailed description concerning the item
”Addressing” is contained in the chapters
”Addressing” of the central units and couplers.
The module address is set on the DIL switch located
under the cover at the top side of the module.When using the central units 07 KR 91, 07 KT 92 or
07 KT 93, the possible module addresses range from
0...61.
In connection with the central units 07 KR 91 and
07 KT 92/KT93 as bus masters, the following address
allocations are valid:The module uses 16 outputs on the CS31 system bus.
I/O configuration
With this module, an I/O configuration is not necessary.
Normal operation
The module initializes itself after power ON. During
initialization all LEDs are ON.
After the initialization, the two red LEDs go out
again, if the bus is running correctly and the module
does not detect any error. The green LED ”Supply”
lights up.
The16 yellow LEDs indicate the signal statuses of
the channels A0...A15