B&R 7EX470.50-1总线控制器,7EX470.50-1使用在哪里
使用上下键从列表中选择对象类型[ZZ]。第1卷:标准卷(称重传感器A和B)、单侧A或单侧B(称重传感器A或B)第2卷:标准卷(称重传感器C和D)、单面C或单面(称重传感器C或D)当选择单侧测量时,测量信号乘以2和在显示器和模拟输出上显示为卷筒纸张力。设置分段滚动的对象类型对象类型SegmentedRoll最多可用于连接到一个、两个或多个传感器的12个称重传感器三个张力电子元件PFEA113。
B&R 7EX470.50-1总线控制器每个PFEA113必须设置为:?一个输入(称重传感器连接到A)?两个输入(连接到A和B的称重传感器)?三个输入(连接到A、B和C的称重传感器)或?四个输入(连接到A、B、C和D的称重传感器)分段滚动比例因子(SRSF)用于补偿总测量张力和当并非所有辊都由分段式称重传感器支撑时,给出总张力的估计值滚动应用。有关SRSF的计算,请参阅。连接多个电子设备(两个或三个PFEA113连接在一起)模拟输入AI1和AI2(见图3-10)用于连接两个或三个PFEA113电子产品在一起。下面的配置示例基于图3-10。如果选择N/m、kN/m、kg/m或pli作为表示单位,则必须输入总腹板宽度这三种电子产品。必须在所有三个电子设备中输入相同的包裹增益值。如果使用比例因子SRSF,则必须计算SRSF,并分别为每个SRSF设置电子装置,另见附录A.3张力电子装置PFEA113的技术数据。1.PFEA113(1)和PFEA113(2)上模拟输出(AO)的配置规则连接到PFEA113(3)上的AI1和AI2:–选择电压输出,因为AI1和AI2只能连接到电压信号。–使用连接信号替代方案,该替代方案包括要连接到输出的称重传感器信号,请参阅第3.12.7节。–将过滤器设置设置为5毫秒(最短的可选择时间)–设置高张力(N、kN、kg、lbs、N/m、kN/m、kg/m或pli)和高输出(V)。
Use up and down keys to select type of object [ZZ] from list.
Roll 1: StandardRoll (load cells A and B), SingleSideA or SingleSideB (load cell A or B)
Roll 2: StandardRoll (load cells C and D), SingleSideC or SingleSideD (load cell C or D)
When single side measurement is selected the measured signal is multiplied by two and
presented as web tension on display and analog output.Setting Object Types for Segmented Roll
Object type SegmentedRoll can be used for up to 12 load cells that are connected to one, two or
three Tension Electronics PFEA113.
Each PFEA113 must be set up for:
? one input (load cell connected to A)
? two inputs (load cells connected to A and B)
? three inputs (load cells connected to A, B and C) or
? four inputs (load cells connected to A, B, C and D)Segmented Roll Scale Factor (SRSF) is used to compensate the total measured tension and
present an estimate of total tension when not all rolls are supported by load cells in a segmented
roll application. For calculations of SRSF, refer to.Connecting Multiple Electronics (two or three PFEA113 connected together)
Analog inputs AI1 and AI2, see Figure 3-10, are used for connecting two or three PFEA113
electronics together. The configuration example below is based on Figure 3-10.
If N/m, kN/m, kg/m or pli is chosen as presentation unit, the total web width must be entered in
all three electronics.
The same wrap gain value must be entered in all three electronics.
If the scale factor SRSF is used, the SRSF must be calculated and set separately for each
electronic unit, see also Appendix A.3 Technical Data for Tension Electronics PFEA113.
1. Configuration rules for analog outputs(AO) on PFEA113 (1) and PFEA113 (2) to be
connected to AI1 and AI2 on PFEA113 (3):
– Choose voltage output, since AI1 and AI2 can only be connected to voltage signals.
– Use the ConnectSignals alternative that includes the load cell signals you want to connect to the output, see Section 3.12.7.
– Set the filter settings to 5 ms (the shortest selectable time).
– Set HighTension (N, kN, kg, lbs, N/m, kN/m, kg/m or pli) and HighOutput (V).